Raman spectroscopy
Raman spectroscopy ( ; named after the physicist C.
≈ 13 min read
Names in other languages
No names in other languages are held for this entry yet.
Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.
Raman spectroscopy ( ; named after the physicist C. V. Raman) is a spectroscopic technique typically used to determine vibrational modes of molecules, although rotational and other low-frequency modes of systems may also be observed. Raman spectroscopy is commonly used in chemistry to provide a structural fingerprint by which molecules can be identified.
Raman spectroscopy relies upon inelastic scattering of photons, known as Raman scattering. A source of monochromatic light, usually from a laser in the visible, near infrared, or near ultraviolet range is used, although X-rays can also be used.
The laser light interacts with molecular vibrations, phonons or other excitations in the system, resulting in the energy of the laser photons being shifted up or down. The shift in energy gives information about the vibrational modes in the system. Time-resolved spectroscopy and infrared spectroscopy typically yield similar yet complementary information.
Typically, a sample is illuminated with a laser beam. Electromagnetic radiation scattered from the illuminated spot is collected with a lens. Raman scattering is typically very weak.
As a result, for many years the main difficulty in collecting Raman spectra was separating the weak inelastically scattered light from the intense Rayleigh scattered laser light (referred to as "laser rejection").…
Raman spectroscopy ( ; named after the physicist C. V. Raman) is a spectroscopic technique typically used to determine vibrational modes of molecules, although rotational and other low-frequency modes of systems may also be observed. Raman spectroscopy is commonly used in chemistry to provide a structural fingerprint by which molecules can be identified.
Raman spectroscopy relies upon inelastic scattering of photons, known as Raman scattering. A source of monochromatic light, usually from a laser in the visible, near infrared, or near ultraviolet range is used, although X-rays can also be used.
The laser light interacts with molecular vibrations, phonons or other excitations in the system, resulting in the energy of the laser photons being shifted up or down. The shift in energy gives information about the vibrational modes in the system. Time-resolved spectroscopy and infrared spectroscopy typically yield similar yet complementary information.
Typically, a sample is illuminated with a laser beam. Electromagnetic radiation scattered from the illuminated spot is collected with a lens. Raman scattering is typically very weak.
As a result, for many years the main difficulty in collecting Raman spectra was separating the weak inelastically scattered light from the intense Rayleigh scattered laser light (referred to as "laser rejection"). Elastic scattered radiation at the wavelength corresponding to the laser line (Rayleigh scattering) is filtered out by either a notch filter, edge pass filter, or a band pass filter, while the rest of the collected light is dispersed onto a detector.
Spontaneous Raman scattering is typically very weak. Historically, Raman spectrometers used holographic gratings and multiple dispersion stages to achieve a high degree of laser rejection. In the past, photomultipliers were the detectors of choice for dispersive Raman setups, which resulted in long acquisition times.
However, modern instrumentation almost universally employs notch or edge filters for laser rejection. Dispersive single-stage spectrographs (axial transmissive (AT) or Czerny–Turner (CT) monochromators) paired with CCD detectors are most common although Fourier transform (FT) spectrometers are also common for use with NIR lasers.
Holographic gratings, which present unique opportunities for optical design in spectroscopy, were initially developed and commercialized by Jobin Yvon in the 1970s. This transition from traditionally ruled gratings to holographic ion-etched gratings was a major leap for high-resolution spectrographs and effectively mitigated early issues with stray light. The name "Raman spectroscopy" typically refers to vibrational Raman spectroscopy using laser wavelengths which are not absorbed by the sample.
There are many variations of Raman spectroscopy including surface-enhanced Raman, resonance Raman, tip-enhanced Raman, polarized Raman, stimulated Raman, transmission Raman, spatially-offset Raman, and hyper Raman. Raman scattering is not limited to molecular vibration, and it can be applied to rotational, rovibronic, and electronic spectroscopy. \Delta \tilde{\nu} = \left( \frac{1}{\lambda_0} - \frac{1}{\lambda_1} \right) \ , where is the Raman shift expressed in wavenumber, is the excitation wavelength, and is the Raman spectrum wavelength.
Most commonly, the unit chosen for expressing wavenumber in Raman spectra is inverse centimeters (cm −1 ). Since wavelength is often expressed in units of nanometers (nm), the formula above can scale for this unit conversion explicitly, giving \Delta \tilde{\nu } (\text{cm}^{-1}) = \left( \frac{1}{\lambda_0 (\text{nm})} - \frac{1}{\lambda_1 (\text{nm})} \right) \times \frac{(10^{7}\text{nm})}{(\text{cm})}.
Raman scattering contrasts with infrared (IR) absorption, where the energy of the absorbed photon matches the difference in energy between the initial and final rovibronic states. The dependence of Raman on the polarizability derivative differs from Infrared spectroscopy, which depends on the electric dipole moment derivative.
This contrasting feature allows rovibronic transitions that might not be active in IR to be analyzed using Raman spectroscopy, as exemplified by the rule of mutual exclusion in centrosymmetric molecules. Transitions which have large Raman intensities often have weak IR intensities and vice versa.
If a bond is strongly polarized, a small change in its length such as that which occurs during a vibration has only a small resultant effect on polarization. Vibrations involving polar bonds (e.g. C-O, N-O, O-H) are therefore, comparatively weak Raman scatterers.
Such polarized bonds, however, carry their electrical charges during the vibrational motion, (unless neutralized by symmetry factors), and this results in a larger net dipole moment change during the vibration, producing a strong IR absorption band. Conversely, relatively neutral bonds (e.g. C-C, C-H, C=C) suffer large changes in polarizability during a vibration.
However, the dipole moment is not similarly affected such that while vibrations involving predominantly this type of bond are strong Raman scatterers, they are weak in the IR. A third vibrational spectroscopy technique, inelastic incoherent neutron scattering (IINS), can be used to determine the frequencies of vibrations in highly symmetric molecules that may be both IR and Raman inactive.
The IINS selection rules, or allowed transitions, differ from those of IR and Raman, so the three techniques are complementary. They all give the same frequency for a given vibrational transition, but the relative intensities provide different information due to the different types of interaction between the molecule and the incoming particles, photons for IR and Raman, and neutrons for IINS.
The symmetry of a vibrational mode is deduced from the depolarization ratio ρ, which is the ratio of the Raman scattering with polarization orthogonal to the incident laser and the Raman scattering with the same polarization as the incident laser: \rho = \frac{I_r}{I_u} Here I_r is the intensity of Raman scattering when the analyzer is rotated 90 degrees with respect to the incident light's polarization axis, and I_u the intensity of Raman scattering when the analyzer is aligned with the polarization of the incident laser. When polarized light interacts with a molecule, it distorts the molecule which induces an equal and opposite effect in the plane-wave, causing it to be rotated by the difference between the orientation of the molecule and the angle of polarization of the light wave.
If \rho \geq \frac{3}{4} , then the vibrations at that frequency are depolarized; meaning they are not totally symmetric. (\alpha_{\rho\sigma})_{if} = \frac{1}{\hbar} \sum_n \left[ \frac{\langle i \vert \mu_\rho \vert n \rangle \langle n \vert \mu_\sigma \vert f \rangle}{\omega_0 + \omega_{nf} + i \Gamma_n} - \frac{\langle i \vert \mu_\sigma \vert n \rangle \langle n \vert \mu_\rho \vert f \rangle}{\omega_0 - \omega_{nf} - i \Gamma_n} \right] \equiv \langle i \vert \hat{\alpha}_{\rho\sigma} \vert f \rangle The polarizability operator connecting the initial and final states expresses the transition polarizability as a matrix element, as a function of the incidence frequency ω 0 .
The directions x, y, and z in the molecular frame are represented by the Cartesian tensor ρ and σ here. Analyzing Raman excitation patterns requires the use of this equation, which is a sum-over-states expression for polarizability. This series of profiles illustrates the connection between a Raman active vibration's excitation frequency and intensity.
This method takes into account sums over Franck-Condon's active vibrational states and provides insight into electronic absorption and emission spectra. Nevertheless, the work highlights a flaw in the sum-over-states method, especially for large molecules like visible chromophores, which are commonly studied in Raman spectroscopy.
The difficulty arises from the potentially infinite number of intermediary steps needed. While lowering the sum at higher vibrational states can help tiny molecules get over this issue, larger molecules find it more challenging when there are more terms in the sum, particularly in the condensed phase when individual eigenstates cannot be resolved spectrally.
To overcome this, two substitute techniques that do not require adding eigenstates can be considered. Among these two methods are available: the transform method. and Heller's time-dependent approach. The goal of both approaches is to take into consideration the frequency-dependent Raman cross-section σ R (ω 0 ) of a particular normal mode.
S_p = 45\!\left(\frac{\partial \alpha_\mathrm{iso}}{\partial Q_p}\right)^{2} + 7\!\left(\frac{\partial \alpha_\mathrm{aniso}}{\partial Q_p}\right)^{2} Where, \alpha is the 3×3 polarizability tensor. \alpha_\mathrm{iso} = \frac{1}{3}(\alpha_{xx}+\alpha_{yy}+\alpha_{zz}) \alpha_\mathrm{aniso} = \sqrt{\frac{1}{2}\!\left[(\alpha_{xx}-\alpha_{yy})^2 + (\alpha_{yy}-\alpha_{zz})^2 + (\alpha_{zz}-\alpha_{xx})^2 + 6(\alpha_{xy}^2+\alpha_{yz}^2+\alpha_{zx}^2)\right]} In the double-harmonic approximations, the potential energy is expanded to the second order near equilibrium (harmonic force fields), while polarizability, is truncated at first order in the normal coordinates. \alpha_{ij} \;=\; -\,\left.\frac{\partial^{2} E(\mathbf{F})}{\partial F_i\,\partial F_j}\right|_{\mathbf{F}=0},\qquad i,j\in\{x,y,z\} In practice, \alpha can be calculated through analytical methods or by employing the finite difference method for energy under small perturbations in \mathbf{F} . The polarizability derivatives used to calculate Raman activities, which could be obtained by the chain rule that relates Cartesian coordinates \mathbf{R} and normal coordinates Q_p : \frac{\partial \boldsymbol{\alpha}}{\partial Q_p} = \sum_i\frac{\partial\boldsymbol{\alpha}}{\partial R_i}\frac{\partial R_i}{\partial Q_p}.
The \partial R_i / \partial Q_p is given by the normalized linear transformation between Cartesian coordinate and mass-weighted normal coordinates: \frac{\partial R_i}{\partial Q_p} = (\mathbf{M}^{-1/2}\mathbf{L})_{ip}, Where M is the diagonal matrix of atomic masses and L is the matrix of orthonormal eigenvectors (normal modes). It is given by diagonalizing the mass-weighted Hessian matrix: \mathbf{H}^{(\mathrm{mw})} = \mathbf{M}^{-1/2}\,\mathbf{H}\,\mathbf{M}^{-1/2}.
The Cartesian Hessian elements are second derivatives of the potential energy with respect to atomic Cartesian coordinates: H_{ab} \;=\; \left.\frac{\partial^2 E}{\partial R_a\,\partial R_b}\right|_{\mathbf{R}=\mathbf{R}_0},\qquad a,b=1,\dots,3N. By diagonalization of the mass-weighted Hessian, we can obtain the eigenvalues \omega_p^2 and eigenvectors \mathbf{L} ; the vibrational wavenumbers \tilde{\nu}_p = \frac{\omega_p}{2\pi c} are Five (or six for nonlinear molecules) near-zero eigenvalues correspond to overall translations and rotations, which need to remove from the modes when we do vibrational analysis. Since the \partial \boldsymbol{\alpha}/\partial \mathbf{R} is known from finite differences or gradient calculation, it will used to calculate Q_p , and further to get the Raman activities.
I_p(\tilde\nu) = K\,(\tilde\nu_\mathrm{in}-\tilde\nu_p)^{4}\tilde\nu_p^{-1}\!\left[45\!\left(\frac{\partial \alpha_\mathrm{iso}}{\partial Q_p}\right)^{2} + 7\!\left(\frac{\partial \alpha_\mathrm{aniso}}{\partial Q_p}\right)^{2}\right]\!\frac{1}{1-\exp(-hc\tilde\nu_p/k_\mathrm{B}T)} where \tilde\nu_\mathrm{in} : the wavenumber of incident light (cm ^{-1} ); \tilde\nu_p : the vibrational wavenumber of mode p ; K = \frac{2\pi^4}{45\epsilon_0^2 c^4} is a physical prefactor; h : Planck constant; c : speed of light; k_\mathrm{B} : Boltzmann constant; T : absolute temperature; Term (\tilde\nu_\mathrm{in}-\tilde\nu_p)^4 provides the characteristic frequency dependence from frequency difference; Last factor is the thermal population correction distinguishing Stokes and anti-Stokes lines Since some thermodynamic calculations ignored in the harmonic approximation, DFT-calculated harmonic frequencies are systematically too high. Hence, an scaling factor f_\mathrm{scale} is applied to vibrational frequencies before comparing simulated spectrum with the experiment: \tilde\nu_\mathrm{corr} = f_\mathrm{scale}\,\tilde\nu_\mathrm{calc} For example, the B3LYP/TZVP scaling factor is 0.965.
Before to calculating the static spectrum, the structure must be optimized to its lowest energy point using the same or an approximate DFT basis set/functional. The mentioned static (harmonic) method also has been integrated into the Gaussian software as default, using the keyword Opt Freq=Raman to calculate.
C_\mathrm{iso}(t) = \langle \alpha_\mathrm{iso}(0)\,\alpha_\mathrm{iso}(t) \rangle, \qquad C_\mathrm{aniso}(t) = \langle \alpha_\mathrm{aniso}(0)\,\alpha_\mathrm{aniso}(t) \rangle and during the Fourier transforms, the isotropic and anisotropic Raman spectra generated as: I_\mathrm{iso}(\omega) \propto \int e^{i\omega t}\,C_\mathrm{iso}(t)\,dt, I_\mathrm{aniso}(\omega) \propto \int e^{i\omega t}\,C_\mathrm{aniso}(t)\,dt. An isotropic media (liquids, gases), the observable Raman spectra under unpolarized detection is a rotational average of the two components: I_\mathrm{Raman}(\omega) = I_\mathrm{iso}(\omega) + \frac{4}{3}\,I_\mathrm{aniso}(\omega).
This expression is derived from the angular momentum averaging of scattered lights from the random molecular orientations. The factor 4/3 the iso/aniso probably contribution.
And the depolarization ratio, often used experimentally to featurize the polarization effects, is defied by: \rho(\omega) = \frac{I_\perp(\omega)}{I_\parallel(\omega)}= \frac{3\,I_\mathrm{aniso}(\omega)}{45\,I_\mathrm{iso}(\omega) + 4\,I_\mathrm{aniso}(\omega)}. The ratio show the information on the symmetry of the vibrational modes.
So, from the time dependent polarizability tensor \boldsymbol{\alpha}(t) , the isotropic and anisotropic time series can be obtained. Their autocorrelation functions are calculated, Fourier transformed, and finally combined using the rotational averaging method to generate the total Raman spectrum.
This polarizability-autocorrelation Fourier transform method naturally integrates anharmonic coupling, temperature broadening, and the polarization effects. It is providing a realistic description of Raman spectroscopy beyond the harmonic approximation.
External links
DoITPoMS Teaching and Learning Package – Raman Spectroscopy – an introduction to Raman spectroscopy, aimed at undergraduate level.
Text derived from https://en.wikipedia.org/w/index.php?oldid=1378632263 under CC BY-SA 4.0; modifications have been made.