Rectifier

Uses your system voice; voice and rate in settings.

Snapshot

≈ 14 min read

Names in other languages

No names in other languages are held for this entry yet.

Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.

) and associated mounting hardware. The heavy threaded stud attaches the device to a heatsink to dissipate heat. A rectifier is an electrical device that converts alternating current (AC), which periodically reverses direction, to direct current (DC), which flows in only one direction. The process is known as rectification, since it "straightens" the direction of current. Physically, rectifiers take a number of forms, including vacuum tube diodes, wet chemical cells, mercury-arc valves, stacks of copper and selenium oxide plates, semiconductor diodes, silicon-controlled rectifiers and other silicon-based semiconductor switches. Historically, even synchronous electromechanical switches and motor–generator sets have been used. Early radio receivers, called crystal radios, used a "cat's whisker" of fine wire pressing on a crystal of galena (lead sulfide) to serve as a point-contact rectifier or "crystal detector". Rectifiers have many uses, but are often found serving as components of DC power supplies and high-voltage direct current power transmission systems. Rectification may serve in roles other than to generate direct current for use as a source of power. As noted, rectifiers can serve as detectors of radio signals. In gas heating systems, flame rectification is used to detect the presence of a flame.…

) and associated mounting hardware. The heavy threaded stud attaches the device to a heatsink to dissipate heat. A rectifier is an electrical device that converts alternating current (AC), which periodically reverses direction, to direct current (DC), which flows in only one direction. The process is known as rectification, since it "straightens" the direction of current. Physically, rectifiers take a number of forms, including vacuum tube diodes, wet chemical cells, mercury-arc valves, stacks of copper and selenium oxide plates, semiconductor diodes, silicon-controlled rectifiers and other silicon-based semiconductor switches. Historically, even synchronous electromechanical switches and motor–generator sets have been used. Early radio receivers, called crystal radios, used a "cat's whisker" of fine wire pressing on a crystal of galena (lead sulfide) to serve as a point-contact rectifier or "crystal detector". Rectifiers have many uses, but are often found serving as components of DC power supplies and high-voltage direct current power transmission systems. Rectification may serve in roles other than to generate direct current for use as a source of power. As noted, rectifiers can serve as detectors of radio signals. In gas heating systems, flame rectification is used to detect the presence of a flame. Depending on the type of alternating current supply and the arrangement of the rectifier circuit, the output voltage may require additional smoothing to produce a uniform steady voltage. Many applications of rectifiers, such as power supplies for radio, television and computer equipment, require a steady constant DC voltage (as would be produced by a battery). In these applications, the output of the rectifier is smoothed by an electronic filter, which may be a capacitor, choke, or set of capacitors, chokes and resistors, possibly followed by a voltage regulator to produce a steady voltage. A device that performs the opposite function, that is converting DC to AC, is called an inverter. V_\mathrm {rms} &= \frac{V_\mathrm {peak}}{2}\\[8pt] V_\mathrm {dc} &= \frac{V_\mathrm {peak}}{\pi} \end{align} where: V dc , V av – the DC or average output voltage, V peak , the peak value of the phase input voltages, V rms , the root mean square (RMS) value of output voltage. V_\mathrm{dc}=V_\mathrm {av}&=\frac{2 \cdot V_\mathrm{peak}}{\pi}\\[8pt] V_\mathrm {rms}&=\frac {V_\mathrm{peak}}{\sqrt 2} \end{align} Very common double-diode rectifier vacuum tubes contained a single common cathode and two anodes inside a single envelope, achieving full-wave rectification with positive output. The 5U4 and the 80/5Y3 (4 pin)/(octal) were popular examples of this configuration. The peak values V_\mathrm{peak} of this three-pulse DC voltage are calculated from the RMS value V_\mathrm{LN} of the input phase voltage (line to neutral voltage, 120 V in North America, 240 V within Europe at mains operation): V_\mathrm{peak} = \sqrt 2 \cdot V_{\mathrm{LN}} . The average no-load output voltage V_\mathrm {av} results from the integral under the graph of a positive half-wave with the period duration of \frac{2}{3} \pi (from 30° to 150°): \begin{align} V_\mathrm{dc} = {} & V_\mathrm {av} = \frac{1}{\frac{2}{3} \pi} \int_{30^\circ}^{150^\circ} V_\mathrm{peak} \sin\varphi \, \mathrm d\varphi = \frac{3 V_\mathrm{peak}}{2 \pi} \cdot \left(-\cos 150^\circ + \cos 30^\circ \right) \\[8pt] \Longrightarrow {} & V_\mathrm{dc} = V_\mathrm {av} = \frac{3 \sqrt3 \cdot \sqrt 2 \cdot V_\mathrm{LN}}{2 \pi} \\[8pt] \Longrightarrow {} & V_\mathrm{av} = \frac{3 \sqrt 6 \cdot V_\mathrm{LN}}{2 \pi} \approx 1.17 V_\mathrm{LN} \end{align} The ideal, no-load average output voltage V_\mathrm{av} of the B6 circuit results from the integral under the graph of a DC voltage pulse with the period duration of \frac{1}{3} \pi (from 60° to 120°) with the peak value \hat v_{\mathrm{DC}} = \sqrt 3 \cdot V_\mathrm{peak} : \begin{align} V_\mathrm{dc} = {} & V_\mathrm {av} = \frac{1}{\frac{1}{3} \pi} \int_{60^\circ}^{120^\circ} \sqrt 3 \cdot V_\mathrm{peak} \cdot \sin\varphi \cdot \mathrm d\varphi \\[8pt] = {} & \frac{3 \sqrt 3 \cdot V_\mathrm{peak}}{\pi} \cdot \left(-\cos 120^\circ + \cos 60^\circ \right) \\[8pt] \Longrightarrow V_\mathrm{dc}=V_\mathrm {av}= \frac{3\sqrt{3} \cdot \sqrt 2 \cdot V_\mathrm{LN}}{\pi} \Longrightarrow V_\mathrm {av} = \frac{3\sqrt 6 \cdot V_\mathrm{LN}}{\pi} \approx 2.34 V_\mathrm{LN} If the three-phase bridge rectifier is operated symmetrically (as positive and negative supply voltage), the center point of the rectifier on the output side (or the so-called isolated reference potential) opposite the center point of the transformer (or the neutral conductor) has a potential difference in the form of a triangular common-mode voltage. For this reason, these two centers must never be connected to each other; otherwise, short-circuit currents would flow. The ground of the three-phase bridge rectifier in symmetrical operation is thus decoupled from the neutral conductor or the earth of the mains voltage. Powered by a transformer, earthing of the center point of the bridge is possible, provided that the secondary winding of the transformer is electrically isolated from the mains voltage and the star point of the secondary winding is not on earth. In this case, however, (negligible) leakage currents are flowing over the transformer windings. The common-mode voltage is formed out of the respective average values of the differences between the positive and negative phase voltages, which form the pulsating DC voltage. The peak value of the delta voltage \hat v_{\mathrm{common-mode}} amounts of the peak value of the phase input voltage V_\mathrm{peak} and is calculated with V_\mathrm{peak} minus half of the DC voltage at 60° of the period: \begin{align} \hat v_{\text{common mode}} = {} & V_\mathrm{peak} - \frac{\sqrt 3 \cdot V_\mathrm{peak} \cdot \sin 60^\circ}{2} \\[8pt] V_{\text{common mode}} = \frac{\hat v_{\text{common mode}}}{\sqrt 3} If the circuit is operated asymmetrically (as a simple supply voltage with just one positive pole), both the positive and negative poles (or the isolated reference potential) are pulsating opposite the center (or the ground) of the input voltage, analogously to the positive and negative waveforms of the phase voltages. However, the differences in the phase voltages result in the six-pulse DC voltage (over the duration of a period). The strict separation of the transformer center from the negative pole (otherwise short-circuit currents will flow) or a possible grounding of the negative pole when powered by an isolating transformer applies correspondingly to the symmetrical operation. V_\mathrm{dc}=V_\mathrm {av}=\frac{3\sqrt 3 \cdot V_\mathrm{peak}}{\pi} \cdot \cos \alpha Or, expressed in terms of the line to line input voltage: V_\mathrm{dc}=V_\mathrm {av}=\frac{3 V_\mathrm {LLpeak}}{\pi} \cdot \cos \alpha where: V LLpeak is the peak value of the line-to-line input voltages, V peak is the peak value of the phase (line to neutral) input voltages, and α is the firing angle of the thyristor (0 if diodes are used to perform rectification) The above equations are only valid when no current is drawn from the AC supply or in the theoretical case when the AC supply connections have no inductance. In practice, the supply inductance causes a reduction of DC output voltage with increasing load, typically in the range 10–20% at full load. The effect of supply inductance is to slow down the transfer process (called commutation) from one phase to the next. As result of this is that at each transition between a pair of devices, there is a period of overlap during which three (rather than two) devices in the bridge are conducting simultaneously. The overlap angle is usually referred to by the symbol μ (or u), and may be 20 30° at full load. With supply inductance taken into account, the output voltage of the rectifier is reduced to V_\mathrm{dc} = V_\mathrm {av}=\frac{3 V_\mathrm {LLpeak}}{\pi} \cdot \cos (\alpha + \mu). The overlap angle μ is directly related to the DC current, and the above equation may be re-expressed as V_\mathrm{dc}=V_\mathrm {av}=\frac{3 V_\mathrm {LLpeak}}{\pi} \cdot \cos(\alpha) - 6 f L_\mathrm {c} I_\mathrm {d} where: L c is the commutating inductance per phase, and I d is the direct current. P_\mathrm {AC} = {V_\mathrm{peak} \over 2} \cdot {I_\mathrm {peak} \over 2} (the divisors are 2 rather than because no power is delivered on the negative half-cycle) P_\mathrm {DC} = {V_\mathrm{peak} \over \pi} \cdot {I_\mathrm {peak} \over \pi} Thus maximum conversion ratio for a half-wave rectifier is, \eta = {P_\mathrm {DC} \over P_\mathrm {AC}} = { 4 \over \pi ^2 } \approx 40.5\% Similarly, for a full-wave rectifier, P_\mathrm {AC} = {V_\mathrm{peak} \over \sqrt 2} \cdot {I_\mathrm {peak} \over \sqrt 2} P_\mathrm {DC} = {2 \cdot V_\mathrm{peak} \over \pi} \cdot {2 \cdot I_\mathrm {peak} \over \pi} \eta = {P_\mathrm {DC} \over P_\mathrm {AC}} = { 8 \over \pi ^2 } \approx 81.0\% Three-phase rectifiers, especially three-phase full-wave rectifiers, have much greater conversion ratios because the ripple is intrinsically smaller. For a three-phase half-wave rectifier, P_\mathrm {AC} = 3 \cdot {V_\mathrm{peak} \over 2} \cdot {I_\mathrm {peak} \over 2} P_\mathrm {DC} = \frac{3\sqrt{3} \cdot V_\mathrm{peak}}{2 \pi} \cdot \frac{3\sqrt3 \cdot I_\mathrm{peak}}{2 \pi} For a three-phase full-wave rectifier, P_\mathrm {AC} = 3 \cdot {V_\mathrm{peak} \over \sqrt 2} \cdot {I_\mathrm {peak} \over \sqrt 2} P_\mathrm {DC} = \frac{3\sqrt3 \cdot V_\mathrm{peak}} \pi \cdot \frac{3\sqrt3 \cdot I_\mathrm{peak}} \pi \text{T.U.F} = \frac{P_\text{odc}}{\text{VA rating of transformer}} The VA rating of the transformer can be defined as: VA = V_{\mathrm{rms}} \dot I_{\mathrm{rms}} (\text{For secondary coil.})

Rectifier output smoothing

While half-wave and full-wave rectification deliver unidirectional current, neither produces a constant voltage. There is a large AC ripple voltage component at the source frequency for a half-wave rectifier, and twice the source frequency for a full-wave rectifier. Ripple voltage is usually specified peak-to-peak. Producing steady DC from a rectified AC supply requires a smoothing circuit or filter. In its simplest form this can be just a capacitor (functioning as both a smoothing capacitor as well as a reservoir, buffer or bulk capacitor), choke, resistor, Zener diode and resistor, or voltage regulator placed at the output of the rectifier. In practice, most smoothing filters utilize multiple components to efficiently reduce ripple voltage to a level tolerable by the circuit. The filter capacitor releases its stored energy during the part of the AC cycle when the AC source does not supply any power, that is, when the AC source changes its direction of flow of current. The above diagram shows the voltage waveforms of the reservoir performance when supplied from a voltage source with near-zero impedance, such as a mains supply. Both voltages start from zero at time t=0 at the far left of the image; then the capacitor voltage follows the rectified AC voltage as it increases, the capacitor is charged and current is supplied to the load. At the end of the mains quarter cycle, the capacitor is charged to the peak value Vp of the rectifier voltage. Following this, the rectifier input voltage starts to decrease to its minimum value Vmin as it enters the next quarter cycle. This initiates the discharge of the capacitor through the load while the capacitor holds up the output voltage to the load. The size of the capacitor C is determined by the amount of ripple r that can be tolerated, where r=(Vp−Vmin)/Vp. These circuits are very frequently fed from transformers, which may have significant internal impedance in the form of resistance and/or reactance. Transformer internal impedance modifies the reservoir capacitor waveform, changes the peak voltage, and introduces regulation issues.

Vibrating rectifier

battery charger from 1922. It produced at 6 V to charge automobile batteries. These consisted of a resonant reed, vibrated by an alternating magnetic field created by an AC electromagnet, with contacts that reversed the direction of the current on the negative half cycles. They were used in low-power devices, such as battery chargers, to rectify the low voltage produced by a step-down transformer. Another use was in battery power supplies for portable vacuum tube radios, to provide the high DC voltage for the tubes. These operated as a mechanical version of modern solid-state switching inverters, with a transformer to step the battery voltage up, and a set of vibrator contacts on the transformer core, operated by its magnetic field, to repeatedly break the DC battery current to create a pulsing AC to power the transformer. Then a second set of rectifier contacts on the vibrator rectified the high AC voltage from the transformer secondary to DC.

Argon gas electron tube

The General Electric Tungar rectifier was a mercury vapor (ex.:5B24) or argon (ex.:328) gas-filled electron tube device with a tungsten filament cathode and a carbon button anode. It operated similarly to the thermionic vacuum tube diode, but the gas in the tube ionized during forward conduction, giving it a much lower forward voltage drop so it could rectify lower voltages. It was used for battery chargers and similar applications from the 1920s until lower-cost metal rectifiers, and later semiconductor diodes, supplanted it. These were made up to a few hundred volts and a few amperes rating, and in some sizes strongly resembled an incandescent lamp with an additional electrode. The 0Z4 was a gas-filled rectifier tube commonly used in vacuum tube car radios in the 1940s and 1950s. It was a conventional full-wave rectifier tube with two anodes and one cathode, but was unique in that it had no filament (thus the "0" in its type number). The electrodes were shaped such that the reverse breakdown voltage was much higher than the forward breakdown voltage. Once the breakdown voltage was exceeded, the 0Z4 switched to a low-resistance state with a forward voltage drop of about 24 V.

Text derived from https://en.wikipedia.org/w/index.php?oldid=1367200865 under CC BY-SA 4.0; modifications have been made.

Sources cited in this revision

19 named source(s) extracted from the cited revision. A source with no author is shown by its publication; nothing is invented.