Reduction potential
≈ 7 min read
Names in other languages
No names in other languages are held for this entry yet.
Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.
Redox potential (also known as oxidation / reduction potential, ORP, pe, E_{red} , or E_{h} ) is a measure of the tendency of a chemical species to acquire electrons from, or lose electrons to, an electrode and thereby be reduced or oxidised respectively. Redox potential is expressed in volts (V). Each species has its own intrinsic redox potential; for example, the more positive the reduction potential (reduction potential is more commonly used due to the general formalism in electrochemistry), the greater the species' affinity for electrons and its tendency to be reduced (stronger oxidising agent).
Redox potential (also known as oxidation / reduction potential, ORP, pe, E_{red} , or E_{h} ) is a measure of the tendency of a chemical species to acquire electrons from, or lose electrons to, an electrode and thereby be reduced or oxidised respectively. Redox potential is expressed in volts (V). Each species has its own intrinsic redox potential; for example, the more positive the reduction potential (reduction potential is more commonly used due to the general formalism in electrochemistry), the greater the species' affinity for electrons and its tendency to be reduced (stronger oxidising agent). pe = \frac{E_{H}}{V_T \lambda} = \frac{E_{H}}{0.05916} = 16.903 \, \text{×} \, E_{H} where, V_T=\frac{RT}{F} is the thermal voltage, with , the gas constant ( ), , the absolute temperature in Kelvin (298.15 K = 25 °C = 77 °F), , the Faraday constant (96 485 coulomb/mol of ), and λ = ln(10) ≈ 2.3026. In fact, pe = -\log[e^-] is defined as the negative logarithm of the free electron concentration in solution, and is directly proportional to the redox potential. Sometimes pe is used as a unit of reduction potential instead of E_h , for example, in environmental chemistry. If one normalizes pe of hydrogen to zero, one obtains the relation pe = 16.9\ E_h at room temperature. This notion is useful for understanding redox potential, although the transfer of electrons, rather than the absolute concentration of free electrons in thermal equilibrium, is how one usually thinks of redox potential. Theoretically, however, the two approaches are equivalent. Conversely, one could define a potential corresponding to pH as a potential difference between a solute and pH neutral water, separated by porous membrane (that is permeable to hydrogen ions). Such potential differences actually do occur from differences in acidity on biological membranes. This potential (where pH neutral water is set to 0 V) is analogous with redox potential (where standardized hydrogen solution is set to 0 V), but instead of hydrogen ions, electrons are transferred across in the redox case. Both pH and redox potentials are properties of solutions, not of elements or chemical compounds themselves, and depend on factors like concentration and temperature. The table below shows a few reduction potentials, which can be changed to oxidation potentials by reversing the sign. Reducers donate electrons to (or "reduce") oxidizing agents, which are said to "be reduced by" the reducer. The reducer is stronger when it has a more negative reduction potential and weaker when it has a more positive reduction potential. The more positive the reduction potential, the greater the species' electron affinity and tendency to be reduced. The following table provides the reduction potentials of the indicated reducing agent at 25 °C. For example, among sodium (Na) metal, chromium (Cr) metal, cuprous (Cu + ) ion and chloride (Cl − ) ion, it is Na metal that is the strongest reducing agent while Cl − ion is the weakest; said differently, Na + ion is the weakest oxidizing agent in this list, while molecule is the strongest. Some elements and compounds can be reducing or oxidizing agents, depending on the specific reaction. For example, hydrogen gas is a reducing agent when it reacts with non-metals and an oxidizing agent when it reacts with metals. In the formation of lithium hydride, hydrogen (whose reduction potential is 0.0) acts as an oxidizing agent because it accepts an electron donation from the reducing agent lithium (whose reduction potential is −3.04), which causes lithium to be oxidized and hydrogen to be reduced. In the formation of hydrofluoric acid, hydrogen acts as a reducing agent because it donates its electrons to fluorine, which allows fluorine to be reduced. The standard reduction potential E^{\ominus}_{\text{red}} is measured under standard conditions: T = 298.15 K (25 °C, or 77 °F), a unity activity ( ) for each ion participating into the reaction, a partial pressure of 1 atm (1.013 bar) for each gas taking part into the reaction, and metals in their pure state. The standard reduction potential E^{\ominus}_{\text{red}} is defined relative to the standard hydrogen electrode (SHE) used as reference electrode, which is arbitrarily given a potential of 0.00 V. However, because these can also be referred to as "redox potentials", the terms "reduction potentials" and "oxidation potentials" are preferred by the IUPAC. The two may be explicitly distinguished by the symbols E_{\text{red}} and E_{\text{ox}} , with E_{\text{ox}} = -E_{\text{red}} . a \, A + b \, B + h \, \ce{H+} + z \, e^{-} \quad \ce{ } \quad c \, C + d \, D The half-cell standard reduction potential E^{\ominus}_\text{red} is given by E^{\ominus}_\text{red} (\text{volts}) = -\frac{\Delta G^\ominus}{zF} where \Delta G^\ominus is the standard Gibbs free energy change, is the number of electrons involved, and is Faraday's constant. The Nernst equation relates pH and E_h : E_h = E_\text{red} = E^{\ominus}_\text{red} - \frac{0.05916}{z} \log\left(\frac{\{C\}^c\{D\}^d}{\{A\}^a\{B\}^b}\right) - \frac{0.05916\,h}{z} \text{pH} where curly brackets indicate activities, and exponents are shown in the conventional manner. This equation is the equation of a straight line for E_h as a function of pH with a slope of -0.05916\,\left(\frac{h}{z}\right) volt (pH has no units). This equation predicts lower E_h at higher pH values. This is observed for the reduction of O 2 into H 2 O, or OH − , and for reduction of H + into H 2 : In most (if not all) of the reduction reactions involving oxyanions with a central redox-active atom, oxide anions ( ) being in excess are freed-up when the central atom is reduced. The acid-base neutralization of each oxide ion consumes 2 or one molecule: This is why protons are always engaged as reagent on the left side of the reduction reactions, as can be generally observed in the table of standard reduction potential (data page). If, in very rare instances of reduction reactions, the H + were the products formed by a reduction reaction and thus appearing on the right side of the equation, the slope of the line would be inverse and thus positive (higher E_h at higher pH). An example of that would be the reductive dissolution of magnetite ( ≈ ·FeO with 2 and 1 ) to form 3 (aq) (in which dissolved iron, Fe(II), is divalent and much more soluble than Fe(III)), while releasing one : where: The slope 0.0296 of the line is −1/2 of the −0.05916 value above, since . Additionally, the value −0.0885 corresponds to −0.05916 × 3/2.
Text derived from https://en.wikipedia.org/w/index.php?oldid=1376335156 under CC BY-SA 4.0; modifications have been made.