Reflection coefficient

Uses your system voice; voice and rate in settings.

Snapshot

≈ 7 min read

Names in other languages

No names in other languages are held for this entry yet.

Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.

In physics and electrical engineering the reflection coefficient is a parameter that describes how much of a wave is reflected by an impedance discontinuity in the transmission medium. It is equal to the ratio of the amplitude of the reflected wave to the incident wave, with each expressed as phasors. For example, it is used in optics to calculate the amount of light that is reflected from a surface with a different index of refraction, such as a glass surface, or in an electrical transmission line to calculate how much of the electromagnetic wave is reflected by an impedance discontinuity. The reflection coefficient is closely related to the transmission coefficient. The reflectance of a system is also sometimes called a reflection coefficient. Different disciplines have different applications for the term.

In physics and electrical engineering the reflection coefficient is a parameter that describes how much of a wave is reflected by an impedance discontinuity in the transmission medium. It is equal to the ratio of the amplitude of the reflected wave to the incident wave, with each expressed as phasors. For example, it is used in optics to calculate the amount of light that is reflected from a surface with a different index of refraction, such as a glass surface, or in an electrical transmission line to calculate how much of the electromagnetic wave is reflected by an impedance discontinuity. The reflection coefficient is closely related to the transmission coefficient. The reflectance of a system is also sometimes called a reflection coefficient. Different disciplines have different applications for the term. \Gamma = \frac{V^-}{V^+} It can also be defined using the currents associated with the reflected and forward waves, but introducing a minus sign to account for the opposite orientations of the two currents: \Gamma = -\frac{I^-}{I^+} = \frac{V^-}{V^+} The reflection coefficient may also be established using other field or circuit pairs of quantities whose product defines power resolvable into a forward and reverse wave. With electromagnetic plane waves, one uses the ratio of the electric fields of the reflected to that of the incident wave (or magnetic fields, again with a minus sign); the ratio of each wave's electric field E to its magnetic field H is the medium's characteristic impedance, Z_0 , (equal to the impedance of free space if the medium is a vacuum). In the accompanying figure, a signal source with internal impedance Z_S possibly followed by a transmission line of characteristic impedance Z_S is represented by its Thévenin equivalent, driving the load Z_L . For a real (resistive) source impedance Z_S , if we define \Gamma using the reference impedance Z_0 = Z_S then the source's maximum power is delivered to a load Z_L = Z_0 , in which case \Gamma=0 implying no reflected power. More generally, the squared-magnitude of the reflection coefficient |\Gamma|^2 denotes the proportion of that power that is reflected back to the source, with the power actually delivered toward the load being 1-|\Gamma|^2 . Anywhere along an intervening (lossless) transmission line of characteristic impedance Z_0 , the magnitude of the reflection coefficient |\Gamma| will remain the same (the powers of the forward and reflected waves stay the same) but with a different phase. In the case of a short circuited load ( Z_L=0 ), one finds \Gamma=-1 at the load. This implies the reflected wave having a 180° phase shift (phase reversal) with the voltages of the two waves being opposite at that point and adding to zero (as a short circuit demands). \Gamma ={Z_L-Z_0 \over Z_L+Z_0} . This is the coefficient at the load. The reflection coefficient can also be measured at other points on the line. The magnitude of the reflection coefficient in a lossless transmission line is constant along the line (as are the powers in the forward and reflected waves). However its phase will be shifted by an amount dependent on the electrical distance \phi from the load. If the coefficient is measured at a point L meters from the load, so the electrical distance from the load is \phi = 2\pi L/\lambda radians, the coefficient \Gamma' at that point will be \Gamma' =\Gamma e^{-i \, 2 \phi} Note that the phase of the reflection coefficient is changed by twice the phase length of the attached transmission line. That is to take into account not only the phase delay of the reflected wave, but the phase shift that had first been applied to the forward wave, with the reflection coefficient being the quotient of these. The reflection coefficient so measured, \Gamma' , corresponds to an impedance which is generally dissimilar to Z_L present at the far side of the transmission line. The complex reflection coefficient (in the region | \Gamma| \le 1 , corresponding to passive loads) may be displayed graphically using a Smith chart. The Smith chart is a polar plot of \Gamma , therefore the magnitude of \Gamma is given directly by the distance of a point to the center (with the edge of the Smith chart corresponding to |\Gamma|=1 ). Its evolution along a transmission line is likewise described by a rotation of 2\phi around the chart's center. Using the scales on a Smith chart, the resulting impedance (normalized to Z_0 ) can directly be read. Before the advent of modern electronic computers, the Smith chart was of particular use as a sort of analog computer for this purpose. The reflected power in terms of the reflection coefficient is: P_{reflected} = P_{incident} |\Gamma|^2 . SWR = {1+| \Gamma | \over 1- | \Gamma | } . Along a lossless transmission line of characteristic impedance Z 0 , the SWR signifies the ratio of the voltage (or current) maxima to minima (or what it would be if the transmission line were long enough to produce them). The above calculation assumes that \Gamma has been calculated using Z 0 as the reference impedance. Since it uses only the magnitude of \Gamma , the SWR intentionally ignores the specific value of the load impedance Z L responsible for it, but only the magnitude of the resulting impedance mismatch. That SWR remains the same wherever measured along a transmission line (looking towards the load) since the addition of a transmission line length to a load Z_L only changes the phase, not magnitude of \Gamma . While having a one-to-one correspondence with reflection coefficient, SWR is the most commonly used figure of merit in describing the mismatch affecting a radio antenna or antenna system. It is most often measured at the transmitter side of a transmission line, but having, as explained, the same value as would be measured at the antenna (load) itself. |\Gamma_\mathrm{in}| = \left|S_{11} + \frac{S_{12}S_{21}\Gamma_L}{1-S_{22}\Gamma_L}\right| and |\Gamma_\mathrm{out}| = \left|S_{22} + \frac{S_{12}S_{21}\Gamma_S}{1-S_{11}\Gamma_S} \right|

See also

Microwave Mismatch loss Reflections of signals on conducting lines Scattering parameters Transmission coefficient Target strength Hagen–Rubens relation Reflection phase change

References

Figure 8-2 and Eqn. 8-1 Pg. 279

External links

Flash tutorial for understanding reflection A flash program that shows how a reflected wave is generated, the reflection coefficient and VSWR Application for drawing standing wave diagrams including the reflection coefficient, input impedance, SWR, etc.

Text derived from https://en.wikipedia.org/w/index.php?oldid=1378806400 under CC BY-SA 4.0; modifications have been made.

Sources cited in this revision

No external citation was extracted for this revision. That is a statement about the source, not a claim that none exists.