Resuscitator

Uses your system voice; voice and rate in settings.

Snapshot

≈ 5 min read

Names in other languages

No names in other languages are held for this entry yet.

Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.

A resuscitator is a device using positive pressure to inflate the lungs of an unconscious person who is not breathing, in order to keep them oxygenated and alive. There are three basic types: a manual version (also known as a bag valve mask) consisting of a mask and a large hand-squeezed plastic bulb using ambient air, or with supplemental oxygen from a high-pressure tank. The second type is the expired air or breath powered resuscitator. The third type is an oxygen powered resuscitator. These are driven by pressurized gas delivered by a regulator, and can either be automatic or manually controlled. The most popular type of gas powered resuscitator are time cycled, volume constant ventilators. In the early days of pre-hospital emergency services, pressure cycled devices like the Pulmotor were popular but yielded less than satisfactory results. Most modern resuscitators are designed to allow the patient to breathe on his own should he recover the ability to do so. All resuscitation devices should be able to deliver more than 85% oxygen when a gas source is available.

A resuscitator is a device using positive pressure to inflate the lungs of an unconscious person who is not breathing, in order to keep them oxygenated and alive. There are three basic types: a manual version (also known as a bag valve mask) consisting of a mask and a large hand-squeezed plastic bulb using ambient air, or with supplemental oxygen from a high-pressure tank. The second type is the expired air or breath powered resuscitator. The third type is an oxygen powered resuscitator. These are driven by pressurized gas delivered by a regulator, and can either be automatic or manually controlled. The most popular type of gas powered resuscitator are time cycled, volume constant ventilators. In the early days of pre-hospital emergency services, pressure cycled devices like the Pulmotor were popular but yielded less than satisfactory results. Most modern resuscitators are designed to allow the patient to breathe on his own should he recover the ability to do so. All resuscitation devices should be able to deliver more than 85% oxygen when a gas source is available.

Mechanism and function

Manual resuscitators

Manual resuscitators, also known as bag valve masks, consist of a flexible oro-nasal face-mask with non-return valves and a large hand-squeezed plastic bulb using ambient air, or with supplemental oxygen from a high-pressure tank. The mask covers the mouth and nose, and has a peripheral seal that fits most face shapes, and is generally held in place by the operator.

Expired air resuscitators

A pocket mask, or pocket face mask or CPR mask, is an expired air resuscitation device used to safely deliver rescue breaths during a cardiac arrest or respiratory arrest. It is a small portable device used in the pre-hospital setting to provide emergency ventilation to a patient who is either in respiratory failure or cardiac arrest. The pocket mask is designed to be placed over the lower face of the patient, creating a seal enclosing both the mouth and nose. Air is then administered to the patient by the responder who exhales through a one-way filter valve. The system is capable of delivering up to 16% oxygen with exhaled air. Modern pocket masks have either a built in one-way valve or a disposable filter to protect the operator responder from potentially infectious bodily fluids, such as vomit or blood. Many masks also have a built-in oxygen addition tube, allowing for administration of 50-60% oxygen.

Oxygen powered resuscitator

An oxygen powered resuscitator is a resuscitator that is powered automatically or manually, transmitting oxygen to the patient that is not breathing or having difficulty breathing. Automatic resuscitators allow the operator to set a fixed rate and amount of positive pressure. Manual resuscitators may require a bag to squeeze or valve to operate.

References

External links

Kiss of Life CPR Mask It began with the Pulmotor: One Hundred Years of Artificial Ventilation by Ernst Bahns, published by Dräger Medical AG & Co. KG, Lübeck, Germany (original manufacturers of the Pulmotor, and many other ventilation items, to the present day) (a lengthy, illustrated history of the development of artificial ventilation, interwoven with the publishers' own apparently self-promotional corporate history).

Pulmotor

"1907: The first mechanical ventilator: The Pulmotor," by John Bottrell (registered respiratory therapist), April 19, 2017, Asthma History blog, retrieved April 12, 2020 "Draeger Pulmotor", Wood Library-Museum of Anesthesiology "The Return of the Pulmotor as a 'Resuscitator': A Back-Step toward the Death of Thousands," by Yandell Henderson, December 1943, Science. It began with the Pulmotor: One Hundred Years of Artificial Ventilation by Ernst Bahns, published by Dräger Medical AG & Co. KG, Lübeck, Germany (original manufacturers of the Pulmotor).

Text derived from https://en.wikipedia.org/w/index.php?oldid=1372837096 under CC BY-SA 4.0; modifications have been made.

Sources cited in this revision

8 named source(s) extracted from the cited revision. A source with no author is shown by its publication; nothing is invented.