Lesson plan
SAIFI
The System Average Interruption Frequency Index (SAIFI) is commonly used as a reliability index by electric power utilities. This index measures the average number of times that a system customer experiences an outage during the year or during a given time period. SAIFI is normally calculated on either yearly or monthly basis. SAIFI is calculated as: \mbox{SAIFI} = \frac{\sum{\lambda_i N_i}}{\sum{N_i}} where \lambda_i is the failure rate and N_i is the number of customers for location i . In other words, \mbox{SAIFI} = \frac{\mbox{total number of customer interruptions}}{\mbox{total number of customers served}} Many factors cause power interruptions, including weather, vegetation patterns, and utility practices. Utilities can report interruption duration values with major events (such as snowstorms or hurricanes), without major events, or both. SAIFI is measured in units of interruptions per customer. According to IEEE Standard 1366-1998 the median value for North American utilities is approximately 1.10 interruptions per customer.
Article summary
The System Average Interruption Frequency Index (SAIFI) is commonly used as a reliability index by electric power utilities. This index measures the average number of times that a system customer experiences an outage during the year or during a given time period. SAIFI is normally calculated on either yearly or monthly basis. SAIFI is calculated as: \mbox{SAIFI} = \frac{\sum{\lambda_i N_i}}{\sum{N_i}} where \lambda_i is the failure rate and N_i is the number of customers for location i . In other words, \mbox{SAIFI} = \frac{\mbox{total number of customer interruptions}}{\mbox{total number of customers served}} Many factors cause power interruptions, including weather, vegetation patterns, and utility practices. Utilities can report interruption duration values with major events (such as snowstorms or hurricanes), without major events, or both. SAIFI is measured in units of interruptions per customer. According to IEEE Standard 1366-1998 the median value for North American utilities is approximately 1.10 interruptions per customer.
Key claims
No claims recorded.
Discussion questions
- Summarise the article in your own words. Which single claim would you verify first, and why?
- Which claim in this article is most likely to be revised as the sources update? How would you check its current status?
- If two sources disagreed about one of these facts, what would you need in order to trust one over the other?
Bibliography
No sources recorded.
Key claims and bibliography are generated from the same tracked claims and sources as the article page.