Lesson plan

Smith predictor

The Smith predictor (invented by O. J. M. Smith in 1957) is a type of predictive controller designed to control systems with a significant feedback time delay. The idea can be illustrated as follows. Suppose the plant consists of G(z) followed by a pure time delay z^{-k} . z refers to the Z-transform of the transfer function relating the inputs and outputs of the plant G . As a first step, suppose we only consider G(z) (the plant without a delay) and design a controller C(z) with a closed-loop transfer function H(z)=\frac{C(z) G(z)}{1+C(z)G(z)} that we consider satisfactory. Next, our objective is to design a controller \bar{C}(z) for the plant G(z) z^{-k} so that the closed loop transfer function \bar{H}(z) equals H(z) z^{-k} . Solving \frac{\bar{C} G z^{-k}}{1+\bar{C}G z^{-k}} = z^{-k} \frac{C G }{1 + C G} , we obtain \bar{C} = \frac{C}{1+CG(1-z^{-k})} . The controller is implemented as shown in the following figure, where G(z) has been changed to \hat{G}(z) to indicate that it is a model used by the controller. Note that there are two feedback loops. The outer control loop feeds the output back to the input, as usual. However, this loop alone would not provide satisfactory control, because of the delay; this loop is feeding back outdated information.…

Back to article

Article summary

The Smith predictor (invented by O. J. M. Smith in 1957) is a type of predictive controller designed to control systems with a significant feedback time delay. The idea can be illustrated as follows. Suppose the plant consists of G(z) followed by a pure time delay z^{-k} . z refers to the Z-transform of the transfer function relating the inputs and outputs of the plant G . As a first step, suppose we only consider G(z) (the plant without a delay) and design a controller C(z) with a closed-loop transfer function H(z)=\frac{C(z) G(z)}{1+C(z)G(z)} that we consider satisfactory. Next, our objective is to design a controller \bar{C}(z) for the plant G(z) z^{-k} so that the closed loop transfer function \bar{H}(z) equals H(z) z^{-k} . Solving \frac{\bar{C} G z^{-k}}{1+\bar{C}G z^{-k}} = z^{-k} \frac{C G }{1 + C G} , we obtain \bar{C} = \frac{C}{1+CG(1-z^{-k})} . The controller is implemented as shown in the following figure, where G(z) has been changed to \hat{G}(z) to indicate that it is a model used by the controller. Note that there are two feedback loops. The outer control loop feeds the output back to the input, as usual. However, this loop alone would not provide satisfactory control, because of the delay; this loop is feeding back outdated information.…

Key claims

No claims recorded.

Discussion questions

  1. Summarise the article in your own words. Which single claim would you verify first, and why?
  2. Which claim in this article is most likely to be revised as the sources update? How would you check its current status?
  3. If two sources disagreed about one of these facts, what would you need in order to trust one over the other?

Bibliography

No sources recorded.

Key claims and bibliography are generated from the same tracked claims and sources as the article page.