Specific absorption rate

Uses your system voice; voice and rate in settings.

Snapshot

≈ 3 min read

Names in other languages

No names in other languages are held for this entry yet.

Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.

Specific absorption rate (SAR) is a measure of the rate at which energy is absorbed per unit mass by a human body when exposed to a radio frequency (RF) electromagnetic field. It is defined as the power absorbed per mass of tissue and has units of watts per kilogram (W/kg). SAR is usually averaged either over the whole body, or over a small sample volume (typically 1 g or 10 g of tissue). The value cited is then the maximum level measured in the body part studied over the stated volume or mass.

Specific absorption rate (SAR) is a measure of the rate at which energy is absorbed per unit mass by a human body when exposed to a radio frequency (RF) electromagnetic field. It is defined as the power absorbed per mass of tissue and has units of watts per kilogram (W/kg). SAR is usually averaged either over the whole body, or over a small sample volume (typically 1 g or 10 g of tissue). The value cited is then the maximum level measured in the body part studied over the stated volume or mass. \text{SAR} = \frac{1}{V}\int_\text{sample} \frac{\sigma(\mathbf{r}) |\mathbf{E}(\mathbf{r})|^2}{\rho(\mathbf{r})} \,d\mathbf{r}, where \sigma is the sample electrical conductivity, E is the RMS electric field, \rho is the sample density, V is the volume of the sample. SAR measures exposure to fields between 100 kHz and 10 GHz (known as radio waves). It is commonly used to measure power absorbed from mobile phones and during MRI scans. The value depends heavily on the geometry of the part of the body that is exposed to the RF energy and on the exact location and geometry of the RF source. Thus tests must be made with each specific source, such as a mobile phone model and at the intended position of use. Normal operating mode: Partial body SAR = 10 W/kg − (8 W/kg × exposed patient mass / patient mass). 1st level controlled: Partial body SAR = 10 W/kg − (6 W/kg × exposed patient mass / patient mass). (c) In cases where the orbit is in the field of a small local RF transmit coil, care should be taken to ensure that the temperature rise is limited to 1 °C. The FCC regulations for SAR are contained in 47 C.F.R. 1.1307(b), 1.1310, 2.1091, 2.1093 and also discussed in OET Bulletin No. 56, "Questions and Answers About the Biological Effects and Potential Hazards of Radiofrequency Electromagnetic Fields." Example of a detailed SAR report from the FCC web site (for an Apple iPod Touch 4th generation); hosted at 3rd party website Manufacturers' SAR official websites Apple Samsung Sony Huawei FCC Regulations OET Bulletin No. 56, "Questions and Answers About the Biological Effects and Potential Hazards of Radiofrequency Electromagnetic Fields."

Text derived from https://en.wikipedia.org/w/index.php?oldid=1377110734 under CC BY-SA 4.0; modifications have been made.

Sources cited in this revision

4 named source(s) extracted from the cited revision. A source with no author is shown by its publication; nothing is invented.