. The spectrum consists of a series of overlapping lines belonging to a vibronic progression Spectral line shape or spectral line profile describes the form of an electromagnetic spectrum in the vicinity of a spectral line – a region of stronger or weaker intensity in the spectrum.

Ideal line shapes include Lorentzian, Gaussian and Voigt functions, whose parameters are the line position, maximum height and half-width. Actual line shapes are determined principally by Doppler, collision and proximity broadening. For each system the half-width of the shape function varies with temperature, pressure (or concentration) and phase.

A knowledge of shape function is needed for spectroscopic curve fitting and deconvolution. L=\frac{1}{1+x^2}, where L signifies a Lorentzian function standardized, for spectroscopic purposes, to a maximum value of 1; x is a subsidiary variable defined as x=\frac{p-p_0}{w/2}, where p_0 is the position of the maximum (corresponding to the transition energy E), p is a position, and w is the full width at half maximum (FWHM), the width of the curve when the intensity is half the maximum intensity (this occurs at the points p = p_0 \pm \frac{w}{2} ).

The unit of p_0 , p and w is typically wavenumber or frequency. The variable x is dimensionless and is zero at p = p_0 . In nuclear magnetic resonance it is possible to measure spectra in a phase sensitive manner.

In those cases it is important to decompose the Lorentzian into its absorptive and dispersive parts, meaning real and imaginary parts respectively. The full Lorentzian lineshape is a result from the Fourier transform of a free induction decay and takes the following form: L(\omega) = \frac{1}{\frac{1}{T_1} + i(\omega-\omega_0)} = \mathcal{F}[e^{-t/T_1}e^{i\omega_0 t}] This can be expanded into the real and imaginary part by quadratic expansion of the denominator: L(\omega) = \frac{1/T_1}{\left(\frac{1}{T_1}\right)^2 + (\omega - \omega_0)^2} - i \frac{(\omega - \omega_0)}{\left(\frac{1}{T_1}\right)^2 + (\omega - \omega_0)^2} Taking only the real part of this expression yields the less general, but more common form of the Lorentz lineshape.

G= e^{-(\ln 2) x^2}. The subsidiary variable, x, is defined in the same way as for a Lorentzian shape. Both this function and the Lorentzian have a maximum value of 1 at x = 0 and a value of 1/2 at x=±1.

V(x;\sigma,\gamma)=\int_{-\infty}^\infty G(x';\sigma)L(x-x';\gamma)\, dx', where σ and γ are half-widths. The computation of a Voigt function and its derivatives are more complicated than a Gaussian or Lorentzian.

A_\lambda=\sum_k \epsilon_{k,\lambda} c_k applies, the total absorbance, A, at wavelength λ, is a linear combination of the absorbance due to the individual components, k, at concentration, c k . ε is an extinction coefficient. In such cases the curve of experimental data may be decomposed into sum of component curves in a process of curve fitting.

This process is also widely called deconvolution. Curve deconvolution and curve fitting are completely different mathematical procedures. Curve fitting can be used in two distinct ways.

The line shapes and parameters p_0 and w of the individual component curves have been obtained experimentally. In this case the curve may be decomposed using a linear least squares process simply to determine the concentrations of the components. This process is used in analytical chemistry to determine the composition of a mixture of the components of known molar absorptivity spectra.

For example, if the heights of two lines are found to be h 1 and h 2 , c 1 = h 1 / ε 1 and c 2 = h 2 / ε 2 . Parameters of the line shape are unknown. The intensity of each component is a function of at least 3 parameters, position, height and half-width.

In addition one or both of the line shape function and baseline function may not be known with certainty. When two or more parameters of a fitting curve are not known the method of non-linear least squares must be used.

The reliability of curve fitting in this case is dependent on the separation between the components, their shape functions and relative heights, and the signal-to-noise ratio in the data. When Gaussian-shaped curves are used for the decomposition of set of N sol spectra into N pks curves, the p_0 and w parameters are common to all N sol spectra.

This allows to calculated the heights of each Gaussian curve in each spectrum (N sol ·N pks parameters) by a (fast) linear least squares fitting procedure, while the p_0 and w parameters (2·N pks parameters) can be obtained with a non-linear least-square fitting on the data from all spectra simultaneously, thus reducing dramatically the correlation between optimized parameters.

Text derived from https://en.wikipedia.org/w/index.php?oldid=1374495820 under CC BY-SA 4.0; modifications have been made.

Provenance

snapshot enwiki-001374495820 · captured 1789208867.0 · version history

Cite this page as: encyclopegia.org, “Spectral line shape”, snapshot enwiki-001374495820. https://encyclopegia.org/a/spectral-line-shape

Sources cited in this revision

5 named source(s) extracted from the cited revision. A source with no author is shown by its publication; nothing is invented.