A spectrum analyzer measures the magnitude of an input signal versus frequency within the full frequency range of the instrument. The primary use is to measure the power of the spectrum of known and unknown signals. The input signal that most common spectrum analyzers measure is electrical; however, spectral compositions of other signals, such as acoustic pressure waves and optical light waves, can be considered through the use of an appropriate transducer. Spectrum analyzers for other types of signals also exist, such as optical spectrum analyzers which use direct optical techniques such as a monochromator to make measurements. By analyzing the spectra of electrical signals, dominant frequency, power, distortion, harmonics, bandwidth, and other spectral components of a signal can be observed that are not easily detectable in time domain waveforms. These parameters are useful in the characterization of electronic devices, such as wireless transmitters. The display of a spectrum analyzer has the amplitude on the vertical axis and frequency displayed on the horizontal axis. To the casual observer, a spectrum analyzer looks like an oscilloscope, which plots amplitude on the vertical axis but time on the horizontal axis. In fact, some lab instruments can function either as an oscilloscope or a spectrum analyzer.
A spectrum analyzer measures the magnitude of an input signal versus frequency within the full frequency range of the instrument. The primary use is to measure the power of the spectrum of known and unknown signals. The input signal that most common spectrum analyzers measure is electrical; however, spectral compositions of other signals, such as acoustic pressure waves and optical light waves, can be considered through the use of an appropriate transducer. Spectrum analyzers for other types of signals also exist, such as optical spectrum analyzers which use direct optical techniques such as a monochromator to make measurements. By analyzing the spectra of electrical signals, dominant frequency, power, distortion, harmonics, bandwidth, and other spectral components of a signal can be observed that are not easily detectable in time domain waveforms. These parameters are useful in the characterization of electronic devices, such as wireless transmitters. The display of a spectrum analyzer has the amplitude on the vertical axis and frequency displayed on the horizontal axis. To the casual observer, a spectrum analyzer looks like an oscilloscope, which plots amplitude on the vertical axis but time on the horizontal axis. In fact, some lab instruments can function either as an oscilloscope or a spectrum analyzer.
Benchtop
This form factor is useful for applications where the spectrum analyzer can be plugged into AC power, which generally means in a lab environment or production/manufacturing area. Bench top spectrum analyzers have historically offered better performance and specifications than the portable or handheld form factor. Bench top spectrum analyzers normally have multiple fans (with associated vents) to dissipate heat produced by the processor. Due to their architecture, bench top spectrum analyzers typically weigh more than . Some bench top spectrum analyzers offer optional battery packs, allowing them to be used away from AC power. This type of analyzer is often referred to as a "portable" spectrum analyzer. \ ST=\frac{k(\mathrm{Span})}{RBW^2} Where ST is sweep time in seconds, k is proportionality constant, Span is the frequency range under consideration in hertz, and RBW is the resolution bandwidth in Hertz. Sweeping too fast, however, causes a drop in displayed amplitude and a shift in the displayed frequency. Also, the animation contains both up- and down-converted spectra, which is due to a frequency mixer producing both sum and difference frequencies. The local oscillator feedthrough is due to the imperfect isolation from the IF signal path in the mixer. For very weak signals, a pre-amplifier is used, although harmonic and intermodulation distortion may lead to the creation of new frequency components that were not present in the original signal. With an FFT based spectrum analyzer, the frequency resolution is \Delta\nu=1/T , the inverse of the time T over which the waveform is measured and Fourier transformed. With Fourier transform analysis in a digital spectrum analyzer, it is necessary to sample the input signal with a sampling frequency \nu_s that is at least twice the bandwidth of the signal, due to the Nyquist limit. A Fourier transform will then produce a spectrum containing all frequencies from zero to \nu_s/2 . This can place considerable demands on the required analog-to-digital converter and processing power for the Fourier transform, making FFT based spectrum analyzers limited in frequency range. over a few minutes Example: for an analyser with of realtime bandwidth (the maximum RF span that can be processed in realtime) approximately (complex) are needed. If the spectrum analyzer produces an FFT calculation is produced every For a FFT a full spectrum is produced approximately every This also gives us our overlap rate of 80% (20 μs − 4 μs) / 20 μs = 80%. t_\mathrm{sweep} = \frac{k \cdot (f_2 - f_1)}{\mathrm{RBW}\times \mathrm{VBW}}. Here t sweep is the sweep time, k is a dimensionless proportionality constant, f 2 − f 1 is the frequency range of the sweep, RBW is the resolution bandwidth, and VBW is the video bandwidth.
Text derived from https://en.wikipedia.org/w/index.php?oldid=1378438244 under CC BY-SA 4.0; modifications have been made.