Lesson plan

Spreeta

Spreeta is an electro-optical device utilizing surface plasmon resonance to detect small changes in refractive index of liquids. The Spreeta device was developed by Texas Instruments, Inc. in the 1990s. Device design incorporates a light-emitting diode (LED) illuminating a thin metal film (usually gold) in the Kretchmann geometry (needed to excite surface plasmons). The reflected light is detected by a photodiode linear array (which translates angle of reflection to pixel position) and the resonance (a dip in the reflectivity at a specific angle of incidence) denotes the refractive index on the outer surface of the metal film. Applications include real-time measurement of binding of antigens to antibodies attached to the sensor surface, monitoring changes in oil quality, and measuring sugar content in drinks (Brix level). The term "Spreeta" is an anglic derivative of SPR-ITA, which combines SPR (for Surface Plasmon Resonance) with "ita" (a Spanish suffix meaning "small"). File:Spreeta Diagram and Sensors(1).jpg|The top image shows an optical diagram of the sensor (in cross-section). The lower-left image is the original integrated sensor. The lower-right image is a smaller version of the sensor with less sensitivity but more amiable to system integration.

Back to article

Article summary

Spreeta is an electro-optical device utilizing surface plasmon resonance to detect small changes in refractive index of liquids. The Spreeta device was developed by Texas Instruments, Inc. in the 1990s. Device design incorporates a light-emitting diode (LED) illuminating a thin metal film (usually gold) in the Kretchmann geometry (needed to excite surface plasmons). The reflected light is detected by a photodiode linear array (which translates angle of reflection to pixel position) and the resonance (a dip in the reflectivity at a specific angle of incidence) denotes the refractive index on the outer surface of the metal film. Applications include real-time measurement of binding of antigens to antibodies attached to the sensor surface, monitoring changes in oil quality, and measuring sugar content in drinks (Brix level). The term "Spreeta" is an anglic derivative of SPR-ITA, which combines SPR (for Surface Plasmon Resonance) with "ita" (a Spanish suffix meaning "small"). File:Spreeta Diagram and Sensors(1).jpg|The top image shows an optical diagram of the sensor (in cross-section). The lower-left image is the original integrated sensor. The lower-right image is a smaller version of the sensor with less sensitivity but more amiable to system integration.

Key claims

No claims recorded.

Discussion questions

  1. Summarise the article in your own words. Which single claim would you verify first, and why?
  2. Which claim in this article is most likely to be revised as the sources update? How would you check its current status?
  3. If two sources disagreed about one of these facts, what would you need in order to trust one over the other?

Bibliography

No sources recorded.

Key claims and bibliography are generated from the same tracked claims and sources as the article page.