time constant

Uses your system voice; voice and rate in settings.

Q1335249Snapshot

≈ 14 min read

Names in other languages

  • Françaisconstante de temps
  • Portuguêsconstante de tempo
  • DeutschZeitkonstante
  • Englishtime constant
  • PolskiStała czasowa
  • 简体中文时间常数
  • 繁體中文時間常數
  • 中文時間常數
  • 日本語時定数

Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.

In physics and engineering, the time constant, usually denoted by the Greek letter (tau), is the parameter characterizing the response to a step input of a first-order, linear time-invariant (LTI) system. The time constant is the main characteristic unit of a first-order LTI system. It gives speed of the response. For example, in a simple RC circuit driven by a step change in voltage, the time constant = RC sets how quickly the capacitor voltage charges toward its new steady-state value. In the time domain, the usual choice to explore the time response is through the step response to a step input, or the impulse response to a Dirac delta function input. In the frequency domain (for example, looking at the Fourier transform of the step response, or using an input that is a simple sinusoidal function of time) the time constant also determines the bandwidth of a first-order time-invariant system, that is, the frequency at which the output signal power drops to half the value it has at low frequencies. Time constants of this kind appear in many areas of physics and engineering, including electrical circuits, thermal systems, excitable membranes in biophysics, radioactive decay, and the response of meteorological sensors.…

In physics and engineering, the time constant, usually denoted by the Greek letter (tau), is the parameter characterizing the response to a step input of a first-order, linear time-invariant (LTI) system. The time constant is the main characteristic unit of a first-order LTI system. It gives speed of the response. For example, in a simple RC circuit driven by a step change in voltage, the time constant = RC sets how quickly the capacitor voltage charges toward its new steady-state value. In the time domain, the usual choice to explore the time response is through the step response to a step input, or the impulse response to a Dirac delta function input. In the frequency domain (for example, looking at the Fourier transform of the step response, or using an input that is a simple sinusoidal function of time) the time constant also determines the bandwidth of a first-order time-invariant system, that is, the frequency at which the output signal power drops to half the value it has at low frequencies. Time constants of this kind appear in many areas of physics and engineering, including electrical circuits, thermal systems, excitable membranes in biophysics, radioactive decay, and the response of meteorological sensors. The time constant is also used to characterize the frequency response of various signal processing systems – magnetic tapes, radio transmitters and receivers, record cutting and replay equipment, and digital filters – which can be modelled or approximated by first-order LTI systems. Other examples include time constant used in control systems for integral and derivative action controllers, which are often pneumatic, rather than electrical. Time constants are a feature of the lumped system analysis (lumped capacity analysis method) for thermal systems, used when objects cool or warm uniformly under the influence of convective cooling or warming. Physically, the time constant represents the elapsed time required for the system response to decay to zero if the system had continued to decay at the initial rate, because of the progressive change in the rate of decay the response will have actually decreased in value to in this time (say from a step decrease). In an increasing system, the time constant is the time for the system's step response to reach of its final (asymptotic) value (say from a step increase). In radioactive decay the time constant is related to the decay constant (λ), and it represents both the mean lifetime of a decaying system (such as an atom) before it decays, or the time it takes for all but 36.8% of the atoms to decay. For this reason, the time constant is longer than the half-life, which is the time for only 50% of the atoms to decay. In practical terms, the time constant is the characteristic time scale over which a first-order system responds to a sudden change in its input. For an increasing first-order response, one time constant is the time it takes the output to reach about 63% (~ 63.2%) of its final value, and for a decreasing response it is the time to fall to about 37% (~ 36.8%) of its initial value. \tau \frac{dV}{dt} + V = f(t) where represents the exponential decay constant and is a function of time V = V(t). The right-hand side is the forcing function describing an external driving function of time, which can be regarded as the system input, to which is the response, or system output. Classical examples for are: The Heaviside step function, often denoted by : u(t) = \begin{cases} 0, & t the impulse function, often denoted by , and also the sinusoidal input function: f(t) = A \sin(2 \pi f t) or f(t) = A e^{j \omega t }, where is the amplitude of the forcing function, is the frequency in Hertz, and is the frequency in radians per second. For a first-order system this differential equation corresponds to a single real pole at -1/τ; smaller values of τ therefore describe systems that respond more quickly to changes in their inputs. V(t) = V_0 e^{-t / \tau} where V_0 = V(t=0) is the initial value of . Thus, the response is an exponential decay with time constant . The time constant sets the characteristic time scale of this decay: after one time constant, the response has decayed to about 37% of its initial value, and after several time constants, it is effectively close to zero. Let t=0 ; then V = V_0 e^0 , and so V=V_0 Let t= \tau ; then V=V_0 e^{-1} \approx 0.37 V_0 . In other words, after a period of one time constant, the function reaches = approximately 37% of its initial value, meaning that about 63% of the total decay has occurred. Let t=5 \tau ; then V = V_0 e^{-5} \approx 0.0067V_0 , which is less than 1% of its original. In many applications, this 1% threshold is taken to mean that, after about five time constants, the exponential response has effectively reached its final value. Let t \to \infty ; then \lim_{t \to \infty} [V_0 e^{-t / \tau}] = 0 . Thus while the function asymptotically decays to 0, it would take an infinite amount of time to actually reach 0. \tau \frac{dV}{dt} + V = f(t) = Ae^{j \omega t }. (Response to a real cosine or sine wave input can be obtained by taking the real or imaginary part of the final result by virtue of Euler's formula.) The general solution to this equation for times , assuming is: \begin{align} V(t) &= V_0e^{-t/\tau} + \frac{Ae^{-t/\tau}}{\tau}\int_0^t \, dt'\ e^{t'/\tau} e^{j\omega t'} \\[1ex] &= V_0 e^{-t/\tau} + \frac{\frac 1 \tau}{j\omega + \frac 1 \tau} A\left( e^{j \omega t} - e^{-t/\tau}\right). \end{align} For long times the decaying exponentials become negligible and the steady-state solution or long-time solution is: V_{\infty}(t) = \frac{1/\tau}{j\omega +1/\tau}Ae^{j \omega t}. The magnitude of this response is: |V_{\infty}(t)| = A\frac{1}{\tau\left(\omega^2 +(1/\tau)^2\right)^{1/2}} = A \frac{1}{\sqrt{1+(\omega \tau)^2 }}. By convention, the bandwidth of this system is the frequency where drops to half-value, or where . This is the usual bandwidth convention, defined as the frequency range where power drops by less than half (at most −3 dB). Using the frequency in hertz, rather than radians/s ( ): f_\mathrm{3dB} = \frac {1}{2 \pi \tau}. The notation stems from the expression of power in decibels and the observation that half-power corresponds to a drop in the value of by a factor of 1/√2 or by 3 decibels. Thus, the time constant determines the bandwidth of this system: a smaller time constant corresponds to a higher -3 dB bandwidth (allowing the system to follow faster variations in the input), while a larger time constant corresponds to a lower bandwidth and a slower response. \frac{dV}{dt} + \frac{1}{\tau} V = f(t) = A u(t), with the unit step function. The general solution to this equation for times , assuming is: V(t) = V_0 e^{-t/\tau} + A \tau \left( 1 - e^{-t/\tau}\right). (It may be observed that this response is the limit of the above response to a sinusoidal input.) The long-time solution is time independent and independent of initial conditions: V_{\infty} = A \tau. The time constant remains the same for the same system regardless of the starting conditions. Simply stated, a system approaches its final, steady-state situation at a constant rate, regardless of how close it is to that value at any arbitrary starting point. For example, consider an electric motor whose startup is well modelled by a first-order LTI system. Suppose that when started from rest, the motor takes of a second to reach 63% of its nominal speed of 100 RPM, or 63 RPM—a shortfall of 37 RPM. Then it will be found that after the next of a second, the motor has sped up an additional 23 RPM, which equals 63% of that 37 RPM difference. This brings it to 86 RPM—still 14 RPM low. After a third of a second, the motor will have gained an additional 9 RPM (63% of that 14 RPM difference), putting it at 95 RPM. In fact, given any initial speed of a second later this particular motor will have gained an additional \tau = \frac{ L }{ R } where R is the resistance (in ohms) and L is the inductance (in henrys). Similarly, in an RC circuit composed of a single resistor and capacitor, the time constant \tau (in seconds) is: \tau = R C where R is the resistance (in ohms) and C is the capacitance (in farads). Electrical circuits are often more complex than these examples, and may exhibit multiple time constants (See Step response and Pole splitting for some examples.) In the case where feedback is present, a system may exhibit unstable, increasing oscillations. In addition, physical electrical circuits are seldom truly linear systems except for very low amplitude excitations; however, the approximation of linearity is widely used. In digital electronic circuits another measure, the FO4 (fanout of 4) is often used. This can be converted to time constant units via the equation 5\tau = \text{FO4} . For example, if R = 100 kΩ and C = 10 µF, the time constant is τ = RC = 1s, so the capacitor voltage reaches about 63% of its final value after 1 second following a step change in the applied voltage. F = hA_s \left( T(t) - T_a\right ), where h is the heat transfer coefficient, and A s is the surface area, T is the temperature function, i.e., T(t) is the body temperature at time t, and T a is the constant ambient temperature. The positive sign indicates the convention that F is positive when heat is leaving the body because its temperature is higher than the ambient temperature (F is an outward flux). As heat is lost to the ambient, this heat transfer leads to a drop in temperature of the body given by: \rho c_p V \frac {dT}{dt} = -F, where ρ = density, c p = specific heat and V is the body volume. The negative sign indicates the temperature drops when the heat transfer is outward from the body (that is, when F > 0). Equating these two expressions for the heat transfer, \rho c_p V \frac {dT}{dt} = -hA_s \left( T(t) - T_a \right). Evidently, this is a first-order LTI system that can be cast in the form: \frac {dT}{dt} +\frac {1}{\tau} T = \frac{1}{\tau} T_a, with \tau = \frac{\rho c_p V}{hA_s}. In other words, larger masses ρV with higher heat capacities c p lead to slower changes in temperature (longer time constant τ), while larger surface areas A s with higher heat transfer h lead to more rapid temperature change (shorter time constant τ). This lumped-parameter model is typically valid when internal temperature gradients are small, for example when the Biot number is less than about 0.1. Comparison with the introductory differential equation suggests the possible generalization to time-varying ambient temperatures T a . However, retaining the simple constant ambient example, by substituting the variable ΔT ≡ (T − T a ), one finds: \frac {d\Delta T}{dt} +\frac {1}{\tau} \Delta T = 0. Systems for which cooling satisfies the above exponential equation are said to satisfy Newton's law of cooling. The solution to this equation suggests that, in such systems, the difference between the temperature of the system and its surroundings ΔT as a function of time t, is given by: \Delta T(t) = \Delta T_0 e^{-t/\tau}, where ΔT 0 is the initial temperature difference, at time t = 0. In words, the body assumes the same temperature as the ambient at an exponentially slow rate determined by the time constant. \tau = r_m c_m where r m is the resistance across the membrane and c m is the capacitance of the membrane. The resistance across the membrane is a function of the number of open ion channels and the capacitance is a function of the properties of the lipid bilayer. The time constant is used to describe the rise and fall of membrane voltage, where the rise is described by V(t) = V_{\max} \left(1 - e^{-t /\tau}\right) and the fall is described by V(t) = V_{\max} e^{-t /\tau} where voltage is in millivolts, time is in seconds, and \tau is in seconds. V max is defined as the maximum voltage change from the resting potential, where V_{\max} = r_m I where r m is the resistance across the membrane and I is the membrane current. Setting for t = \tau for the rise sets V(t) equal to 0.63V max . This means that the time constant is the time elapsed after 63% of V max has been reached Setting for t = \tau for the fall sets V(t) equal to 0.37V max , meaning that the time constant is the time elapsed after it has fallen to 37% of V max . The larger a time constant is, the slower the rise or fall of the potential of a neuron. A long time constant can result in temporal summation, in which repeated synaptic inputs are algebraically summated over time. A short time constant instead favorscoincidence detection through spatial summation, because inputs must arrive within a narrow time window to have a strong combined effect. T_{1/2} = T_\text{HL} = \tau \ln 2. The reciprocal of the time constant is called the decay constant, and is denoted

Text derived from https://en.wikipedia.org/w/index.php?oldid=1373397753 under CC BY-SA 4.0; modifications have been made.

Provenance

snapshot time-constant-155297-58b07221ada575aa · hash 58b07221ada575aaae1fb95c5d5d7e284b256980d098c50813bd5c0a6f83f075 · captured 1788628512.0 · version history

Cite this page as: encyclopegia.org, “time constant”, snapshot time-constant-155297-58b07221ada575aa. https://encyclopegia.org/a/time-constant

Sources cited in this revision

No external citation was extracted for this revision. That is a statement about the source, not a claim that none exists.