Time-domain reflectometer

fault detection A time-domain reflectometer (TDR) is an electronic instrument used to determine the characteristics of electrical lines by observing reflected pulses.

Uses your system voice; voice and rate in settings.

Snapshot

≈ 6 min read

Names in other languages

No names in other languages are held for this entry yet.

Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.

fault detection A time-domain reflectometer (TDR) is an electronic instrument used to determine the characteristics of electrical lines by observing reflected pulses. It can be used to characterize and locate faults in metallic cables (for example, twisted pair wire or coaxial cable), and to locate discontinuities in a connector, printed circuit board, or any other electrical path. \rho = \frac{R_L - Z_0}{R_L + Z_0} where Z_0 is the characteristic impedance of the transmission line.

File:Simple Time Domain Reflectometer Diagram.png|Simple TDR made from lab equipment File:Time Domain Reflectometer made from common lab equipment.JPG|Simple TDR made from lab equipment File:TDR trace of cable with open termination.JPG|TDR trace of a transmission line with an open termination File:TDR trace of cable with a short circuit termination.JPG|TDR trace of a transmission line with a short circuit termination File:TDR trace of cable with a capacitor termination.jpg|TDR trace of a transmission line with a 1nF capacitor termination File:TDR trace of cable terminationed with its characteristic impedance.jpg|TDR trace of a transmission line with an almost ideal termination File:TDR trace of cable with cable terminated on an oscilloscope.JPG|TDR trace of a transmission line terminated on an oscilloscope high impedance input. The blue trace is the pulse as seen at the far end.

It is offset so that the baseline of each channel is visible File:TDR Step Same Baseline.JPG|TDR trace of a transmission line terminated on an oscilloscope high impedance input driven by a step input from a matched source. The blue trace is the signal as seen at the far end.

These traces were produced by a commercial TDR using a step waveform with a 25 ps risetime, a sampling head with a 35 ps risetime, and an SMA cable. The far end of the SMA cable was left open or connected to different adapters. It takes about 3 ns for the pulse to travel down the cable, reflect, and reach the sampling head.

A second reflection (at about 6 ns) can be seen in some traces; it is due to the reflection seeing a small mismatch at the sampling head and causing another "incident" wave to travel down the cable. File:TDR SMA open.svg|TDR of step into disconnected SMA male connector (non-precision open) horizontal: 1 ns/div vertical: 0.5 ρ/div File:TDR SMA APC7 open.svg|TDR of step into disconnected APC-7mm connector File:TDR SMA APC7 prec open.svg|TDR of step into APC-7mm precision open File:TDR SMA APC7 prec load.svg|TDR of step into APC-7mm precision load File:TDR SMA APC7 prec short.svg|TDR of step into APC-7mm precision short File:TDR SMA APC7 prec open 20ps.svg|TDR of step into APC-7mm precision open horizontal: 20 ps/div File:TDR SMA BNC BNC term.svg|TDR of step into mated BNC connector pair; the peak reflection is 0.04 horizontal: 200 ps/div vertical: 20 mρ/div \rho = \frac{Z_\text{t} - Z_\text{o}}{Z_\text{t} + Z_\text{o}} where Z o is defined as the characteristic impedance of the transmission medium and Z t is the impedance of the termination at the far end of the transmission line.

Any discontinuity can be viewed as a termination impedance and substituted as Z t . This includes abrupt changes in the characteristic impedance. As an example, a trace width on a printed circuit board doubled at its midsection would constitute a discontinuity. Some of the energy will be reflected back to the driving source; the remaining energy will be transmitted.

This is also known as a scattering junction. Smith, P., C. Furse, and J. Gunther, 2005. "Analysis of spread spectrum time domain reflectometry for wire fault location".

IEEE Sensors Journal 5:1469–1478. Waddoups, B., C. Furse and M. Schmidt. "Analysis of Reflectometry for Detection of Chafed Aircraft Wiring Insulation".

Department of Electrical and Computer Engineering. Utah State University. Noborio K. 2001.

"Measurement of soil water content and electrical conductivity by time domain reflectometry: A review". Computers and Electronics in Agriculture 31:213–237. Pettinelli E., A. Cereti, A. Galli, and F. Bella, 2002.

"Time domain reflectometry: Calibration techniques for accurate measurement of the dielectric properties of various materials". Review of Scientific Instruments 73:3553–3562. Robinson D.A., S.B. Jones, J.M. Wraith, D. Or and S.P. Friedman, 2003 "A review of advances in dielectric and electrical conductivity measurements in soils using time domain reflectometry".

Vadose Zone Journal 2: 444–475. Robinson, D. A., C. S. Campbell, J. W. Hopmans, B. K. Hornbuckle, Scott B. Jones, R. Knight, F. Ogden, J. Selker, and O. Wendroth, 2008. "Soil moisture measurement for ecological and hydrological watershed-scale observatories: A review."

Vadose Zone Journal 7: 358-389. Topp G.C., J.L. Davis and A.P. Annan, 1980. "Electromagnetic determination of soil water content: measurements in coaxial transmission lines".

Water Resources Research 16:574–582. Topp G.C. and W.D. Reynolds, 1998. "Time domain reflectometry: a seminal technique for measuring mass and energy in soil".

Soil Tillage Research 47:125–132. Topp, G.C. and T.P.A. Ferre, 2002. "Water content", in Methods of Soil Analysis.

Part 4. (Ed. J.H. Dane and G.C. Topp), SSSA Book Series No. 5. Soil Science Society of America, Madison WI.

Dowding, C.H. & O'Connor, K.M. 2000a. "Comparison of TDR and Inclinometers for Slope Monitoring". Geotechnical Measurements—Proceedings of Geo-Denver2000: 80–81. Denver, CO. Dowding, C.H. & O'Connor, K.M. 2000b. "Real Time Monitoring of Infrastructure using TDR Technology".

Structural Materials Technology NDT Conference 2000 Kane, W.F. & Beck, T.J. 1999. "Advances in Slope Instrumentation: TDR and Remote Data Acquisition Systems". Field Measurements in Geomechanics, 5th International Symposium on Field Measurements in Geomechanics: 101–105.

Singapore. Farrington, S.P. and Sargand, S.M., "Advanced Processing of Time Domain Reflectometry for Improved Slope Stability Monitoring", Proceedings of the Eleventh Annual Conference on Tailings and Mine Waste, October, 2004.

Scarpetta, M.; Spadavecchia, M.; Adamo, F.; Ragolia, M.A.; Giaquinto, N. ″Detection and Characterization of Multiple Discontinuities in Cables with Time-Domain Reflectometry and Convolutional Neural Networks″. Sensors 2021, 21, 8032. https://doi.org/10.3390/s21238032 Duncan, D.; Trabold, T.A.; Mohr, C.L.; Berrett, M.K. "MEASUREMENT OF LOCAL VOID FRACTION AT ELEVATED TEMPERATURE AND PRESSURE".

Third World Conference on Experimental Heat Transfer, Fluid Mechanics and Thermodynamics, Honolulu, Hawaii, USA, 31 October-5 November 1993. https://www.mohr-engineering.com/guided-radar-liquid-level-documents-EFP.php

Text derived from https://en.wikipedia.org/w/index.php?oldid=1354809194 under CC BY-SA 4.0; modifications have been made.

Sources cited in this revision

5 named source(s) extracted from the cited revision. A source with no author is shown by its publication; nothing is invented.