Vibration isolation
≈ 8 min read
Names in other languages
No names in other languages are held for this entry yet.
Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.
isolated from its engine Vibration isolation is the prevention of transmission of vibration from one component of a system to other parts of the same system, as in buildings or mechanical systems. Vibration is undesirable in many domains, primarily engineered systems and habitable spaces, and methods have been developed to prevent the transfer of vibration to such systems. Vibrations propagate via mechanical waves and certain mechanical linkages conduct vibrations more efficiently than others. Passive vibration isolation makes use of materials and mechanical linkages that absorb and damp these mechanical waves. Active vibration isolation involves sensors and actuators that produce disruptive interference that cancels-out incoming vibration.
isolated from its engine ]] Vibration isolation is the prevention of transmission of vibration from one component of a system to other parts of the same system, as in buildings or mechanical systems. Vibration is undesirable in many domains, primarily engineered systems and habitable spaces, and methods have been developed to prevent the transfer of vibration to such systems. Vibrations propagate via mechanical waves and certain mechanical linkages conduct vibrations more efficiently than others. Passive vibration isolation makes use of materials and mechanical linkages that absorb and damp these mechanical waves. Active vibration isolation involves sensors and actuators that produce disruptive interference that cancels-out incoming vibration.
Passive isolation
"Passive vibration isolation" refers to vibration isolation or mitigation of vibrations by passive techniques such as rubber pads or mechanical springs, as opposed to "active vibration isolation" or "electronic force cancellation" employing electric power, sensors, actuators, and control systems. Passive vibration isolation is a vast subject, since there are many types of passive vibration isolators used for many different applications. A few of these applications are for industrial equipment such as pumps, motors, HVAC systems, or washing machines; isolation of civil engineering structures from earthquakes (base isolation), sensitive laboratory equipment, valuable statuary, and high-end audio. A basic understanding of how passive isolation works, the more common types of passive isolators, and the main factors that influence the selection of passive isolators:
Negative-stiffness vibration isolator
Negative-stiffness-mechanism (NSM) vibration isolation systems offer a unique passive approach for achieving low vibration environments and isolation against sub-Hertz vibrations. "Snap-through" or "over-center" NSM devices are used to reduce the stiffness of elastic suspensions and create compact six-degree-of-freedom systems with low natural frequencies. Practical systems with vertical and horizontal natural frequencies as low as 0.2 to 0.5 Hz are possible.
Electro-mechanical auto-adjust mechanisms compensate for varying weight loads and provide automatic leveling in multiple-isolator systems, similar to the function of leveling valves in pneumatic systems. All-metal systems can be configured which are compatible with high vacuums and other adverse environments such as high temperatures.
These isolation systems enable vibration-sensitive instruments such as scanning probe microscopes, micro-hardness testers and scanning electron microscopes to operate in severe vibration environments sometimes encountered, for example, on upper floors of buildings and in clean rooms. Such operation would not be practical with pneumatic isolation systems. Similarly, they enable vibration-sensitive instruments to produce better images and data than those achievable with pneumatic isolators.
The theory of operation of NSM vibration isolation systems is summarized, some typical systems and applications are described, and data on measured performance is presented. The theory of NSM isolation systems is explained in References 1 and 2. It is summarized briefly for convenience.
Vertical-motion isolation
A vertical-motion isolator is shown. It uses a conventional spring connected to an NSM consisting of two bars hinged at the center, supported at their outer ends on pivots, and loaded in compression by forces P. The spring is compressed by weight W to the operating position of the isolator, as shown in Figure 1. The stiffness of the isolator is K=K S -K N where K S is the spring stiffness and K N is the magnitude of a negative-stiffness which is a function of the length of the bars and the load P. The isolator stiffness can be made to approach zero while the spring supports the weight W.
Horizontal-motion isolation
A horizontal-motion isolator consisting of two beam-columns is illustrated in Figure. 2. Each beam-column behaves like two fixed-free beam columns loaded axially by a weight load W. Without the weight load the beam-columns have horizontal stiffness K S With the weight load the lateral bending stiffness is reduced by the "beam-column" effect. This behavior is equivalent to a horizontal spring combined with an NSM so that the horizontal stiffness is K=K_S-K_N , and K_N is the magnitude of the beam-column effect. Horizontal stiffness can be made to approach zero by loading the beam-columns to approach their critical buckling load.
Six-degree-of-freedom (six-DOF) isolation
A six-DOF NSM isolator typically uses three isolators stacked in series: a tilt-motion isolator on top of a horizontal-motion isolator on top of a vertical-motion isolator. Figure 3 (Ref. needed) shows a schematic of a vibration isolation system consisting of a weighted platform supported by a single six-DOF isolator incorporating the isolators of Figures 1 and 2 (Figures 1 and 2 are missing). Flexures are used in place of the hinged bars shown in Figure 1. A tilt flexure serves as the tilt-motion isolator. A vertical-stiffness adjustment screw is used to adjust the compression force on the negative-stiffness flexures thereby changing the vertical stiffness. A vertical load adjustment screw is used to adjust for varying weight loads by raising or lowering the base of the support spring to keep the flexures in their straight, unbent operating positions.
Vibration isolation of supporting joint
The equipment or other mechanical components are necessarily linked to surrounding objects (the supporting joint - with the support; the unsupporting joint - the pipe duct or cable), thus presenting the opportunity for unwanted transmission of vibrations. Using a suitably designed vibration-isolator (absorber), vibration isolation of the supporting joint is realized. The accompanying illustration shows the attenuation of vibration levels, as measured before installation of the functioning gear on a vibration isolator as well as after installation, for a wide range of frequencies.
Vibration isolation of unsupporting joint
Vibration isolation of unsupporting joint is realized in the device named branch pipe a of isolating vibration.
Branch pipe a of isolating vibration
Branch pipe a of isolating vibration is a part of a tube with elastic walls for reflection and absorption of waves of the oscillatory energy extending from the working pump over wall of the pipe duct. Is established between the pump and the pipe duct. On an illustration is presented the image a vibration-isolating branch pipe of a series «ВИПБ». In a structure is used the rubber envelope, which is reinforced by a spring. Properties of an envelope are similar envelope to an isolator vibration. Has the device reducing axial effort from action of internal pressure up to zero.
Subframe isolation
Another technique used to increase isolation is to use an isolated subframe. This splits the system with an additional mass/spring/damper system. This doubles the high frequency attenuation rolloff, at the cost of introducing additional low frequency modes which may cause the low frequency behaviour to deteriorate. This is commonly used in the rear suspensions of cars with Independent Rear Suspension (IRS), and in the front subframes of some cars. The graph (see illustration) shows the force into the body for a subframe that is rigidly bolted to the body compared with the red curve that shows a compliantly mounted subframe. Above 42 Hz the compliantly mounted subframe is superior, but below that frequency the bolted in subframe is better.
Semi-active isolation
Semiactive vibration isolators have received attention because they consume less power than active devices and controllability over passive systems.
Sensors for active isolation
Piezoelectric accelerometers and force sensors MEMS accelerometers Geophones Proximity sensors Interferometers
Actuators for active isolation
Linear motors Pneumatic actuators Piezoelectric motors
See also
Active vibration control Base isolation Bushing (isolator) Damped wave Damping ratio Motion amplification, optical-visual technique for detecting and visualizing vibrations Noise, vibration, and harshness Noise and vibration on maritime vessels Oscillation Package cushioning Passive heave compensation Shock absorber Shock mount Sorbothane Soundproofing Vibration Vibration control
References
Platus PhD, David L., SPIE International Society of Optical Engineering - July 1999, Optomechanical Engineering and Vibration Control Negative-Stiffness-Mechanism Vibration Isolation Systems Harris, C., Piersol, A., Harris Shock and Vibration Handbook, Fifth Edition, McGraw-Hill, (2002), A.Kolesnikov «Noise and vibration». Russia. Leningrad. Publ.«Shipbuilding». 1988
External links
White Paper on Active Vibration Isolation for Lithography and Imaging Passive Isolation of Harmonic Excitation Vibration Control for Microscopy sk:Vibrácia
Text derived from https://en.wikipedia.org/w/index.php?oldid=1341415069 under CC BY-SA 4.0; modifications have been made.