Voltage, also known as (electrical) potential difference, electric pressure, or electric tension, is the difference in electric potential between two points. In a static electric field, it corresponds to the work needed per unit of charge to move a positive test charge from the first point to the second point. In the International System of Units (SI), the derived unit for voltage is the volt (V).

Impact

The voltage between points can be caused by the build-up of electric charge (e.g., a capacitor), and from an electromotive force (e.g., electromagnetic induction in a generator). On a macroscopic scale, a potential difference can be caused by electrochemical processes (e.g., cells and batteries), the pressure-induced piezoelectric effect, photovoltaic effect, and the thermoelectric effect. Since voltage is the difference in electric potential, it is a physical scalar quantity. A voltmeter can be used to measure the voltage between two points in a system.

Evidence and sources

Often a common reference potential such as the ground of the system is used as one of the points. In this case, voltage is often mentioned at a point without completely mentioning the other measurement point. A voltage can be associated with either a source of energy or the loss, dissipation, or storage of energy.

Voltage, also known as (electrical) potential difference, electric pressure, or electric tension, is the difference in electric potential between two points. In a static electric field, it corresponds to the work needed per unit of charge to move a positive test charge from the first point to the second point. In the International System of Units (SI), the derived unit for voltage is the volt (V).

The voltage between points can be caused by the build-up of electric charge (e.g., a capacitor), and from an electromotive force (e.g., electromagnetic induction in a generator). On a macroscopic scale, a potential difference can be caused by electrochemical processes (e.g., cells and batteries), the pressure-induced piezoelectric effect, photovoltaic effect, and the thermoelectric effect. Since voltage is the difference in electric potential, it is a physical scalar quantity. A voltmeter can be used to measure the voltage between two points in a system.

Often a common reference potential such as the ground of the system is used as one of the points. In this case, voltage is often mentioned at a point without completely mentioning the other measurement point. A voltage can be associated with either a source of energy or the loss, dissipation, or storage of energy. The SI unit of work per unit charge is the joule per coulomb, where 1 volt = 1 joule (of work) per 1 coulomb of charge.

The old SI definition for volt used power and current; starting in 1990, the Josephson effect was used, and in 2019 physical constants were given defined values for the definition of all SI units. Voltage is denoted symbolically by \Delta V , simplified V, especially in English-speaking countries. Internationally, the symbol U is standardized. The electrochemical potential is the voltage that can be directly measured with a voltmeter.

The Galvani potential that exists in structures with junctions of dissimilar materials, is also work per charge but cannot be measured with a voltmeter in the external circuit (see ). Voltage is defined so that negatively charged objects are pulled towards higher voltages, while positively charged objects are pulled towards lower voltages. Therefore, the conventional current in a wire or resistor always flows from higher voltage to lower voltage. Historically, voltage has been referred to using terms like "tension" and "pressure".

Even today, the term "tension" is still used, for example within the phrase "high tension" (HT) which is commonly used in the contexts of automotive electronics and systems using thermionic valves (vacuum tubes). In electrostatics, the voltage increase from point \mathbf{r}_A to some point \mathbf{r}_B is given by the change in electrostatic potential V from \mathbf{r}_A to \mathbf{r}_B .

By definition, this is: \begin{align} \Delta V_{AB} &= V(\mathbf{r}_B) - V(\mathbf{r}_A) \\ &= -\int_{\mathbf{r}_0}^{\mathbf{r}_B} \mathbf{E} \cdot \mathrm{d}\boldsymbol{\ell} - \left(-\int_{\mathbf{r}_0}^{\mathbf{r}_A} \mathbf{E} \cdot \mathrm{d}\boldsymbol{\ell} \right)\\ &= -\int_{\mathbf{r}_A}^{\mathbf{r}_B} \mathbf{E} \cdot \mathrm{d}\boldsymbol{\ell} \end{align} where \mathbf{E} is the intensity of the electric field.

In this case, the voltage increase from point A to point B is equal to the work done per unit charge, against the electric field, to move the charge from A to B without causing any acceleration. Mathematically, this is expressed as the line integral of the electric field along that path. In electrostatics, this line integral is independent of the path taken.

Under this definition, any circuit where there are time-varying magnetic fields, such as AC circuits, will not have a well-defined voltage between nodes in the circuit, since the electric force is not a conservative force in those cases.

However, at lower frequencies when the electric and magnetic fields are not rapidly changing, this can be neglected (see ). \Delta V_{AB} = -\int_\mathcal{P} \mathbf{E} \cdot \mathrm{d}\boldsymbol{\ell} However, in this case the "voltage" between two points depends on the path taken. \Delta V_{AB} = -\int_{\mathbf{r}_A}^{\mathbf{r}_B} \mathbf{E} \cdot \mathrm{d}\boldsymbol{\ell} as long as the path of integration does not pass through the inside of any component. The above is the same formula used in electrostatics.

This integral, with the path of integration being along the test leads, is what a voltmeter will actually measure. If uncontained magnetic fields throughout the circuit are not negligible, then their effects can be modelled by adding mutual inductance elements. In the case of a physical inductor though, the ideal lumped representation is often accurate. This is because the external fields of inductors are generally negligible, especially if the inductor has a closed magnetic path.

If external fields are negligible, we find that \Delta V_{AB} = -\int_\mathrm{exterior}\mathbf{E}\cdot \mathrm{d}\boldsymbol{\ell}=L\frac{dI}{dt} is path-independent, and there is a well-defined voltage across the inductor's terminals. This is the reason that measurements with a voltmeter across an inductor are often reasonably independent of the placement of the test leads.