Volume correction factor
≈ 4 min read
Names in other languages
No names in other languages are held for this entry yet.
Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.
In thermodynamics, the Volume Correction Factor (VCF), also known as Correction for the effect of Temperature on Liquid (CTL), is a standardized computed factor used to correct for the thermal expansion of fluids, primarily, liquid hydrocarbons at various temperatures and densities. It is typically a number between 0 and 2, rounded to five decimal places which, when multiplied by the observed volume of a liquid, will return a "corrected" value standardized to a base temperature (usually 60 °Fahrenheit or 15 °Celsius).
In thermodynamics, the Volume Correction Factor (VCF), also known as Correction for the effect of Temperature on Liquid (CTL), is a standardized computed factor used to correct for the thermal expansion of fluids, primarily, liquid hydrocarbons at various temperatures and densities. It is typically a number between 0 and 2, rounded to five decimal places which, when multiplied by the observed volume of a liquid, will return a "corrected" value standardized to a base temperature (usually 60 °Fahrenheit or 15 °Celsius). VCF =C_{TL}= \exp\{-\alpha_T\Delta T[1 + 0.8\alpha_T(\Delta T+\delta_T)]\} Where: \exp refers to the mathematical constant, e , raised to the power of \{-\alpha_T\Delta T[1 + 0.8\alpha_T(\Delta T+\delta_T)]\} \Delta T refers to the change in observed temperature ( t ) minus the base temperature ( T ) in degrees Fahrenheit (t - T) . When computing VCF , T is commonly set to 60 °F. \delta_T refers to a small base temperature correction value. If correcting to 60 °F, \delta_T=0 \alpha_{T} refers to the coefficient of thermal expansion at the base temperature. If a base temperature of 60 °F is used, \alpha_{T} is written as \alpha_{60} , and \alpha_{60}=\frac{K_0}{\rho*^2}+\frac{K_1}{\rho*}+{K_2} \rho^* refers to the density [Kg/M 3 ] at the base temperature, T , and 0 psig pressure. When correlated with \alpha_{T} at 60 °F ( \alpha_{60} ) \rightarrow \rho^* = \rho_{60} K_0 , K_1 , and K_2 refer to a specific set of constants, dependent upon the liquid's classification and density at 60 °F E.G. For Crude oils K_0 , K_1 , and K_2 = 341.0957, 0, and 0, respectively. See table below for typical values used. V_{Corrected} = VCF * V_{Observed} Since API gravity is an inverse measure of a liquid's density relative to that of water, it can be calculated by first dividing the liquid's density by the density of water at a base temperature (usually 60 °F) to compute Specific Gravity (SG), then converting the Specific Gravity to Degrees API as follows: SG = \frac{\rho_{Substance}}{\rho_{H2O_T}} \longrightarrow API_{Gravity}=\frac{141.5}{SG}-131.5 Traditionally, VCF / CTL are found by matching the observed temperature and API gravity within standardized books and tables published by the American Petroleum Institute. These methods are often more time-consuming than entering the values into a VCF calculator; however, due to the variance in methodology and computation of constants, the tables published by the American Petroleum Institute are preferred when dealing with the purchase and sale of crude oil and residual fuels. Density of pure water at 60 °F =\ 999.016_{kg/m^3} or 0.999016_{g/cm^3} Note: There is no universal agreement on the exact density of pure water at various temperatures since each industry will often use a different standard. For example the, USGS says it is 0.99907 g/cm 3 . While the relative variance between values may be low, it is best to use the agreed upon standard for the industry you are working in,
Text derived from https://en.wikipedia.org/w/index.php?oldid=1342761756 under CC BY-SA 4.0; modifications have been made.