X-ray optics
X-ray optics is the branch of optics dealing with X-rays, rather than visible light.
≈ 3 min read
X-ray optics. encyclopegia.org, snapshot enwiki-001301522725. /a/x-ray-optics
Names in other languages
No names in other languages are held for this entry yet.
Article bodies are English and are not machine-translated. A name in another language is not a translation of the article.
X-ray optics is the branch of optics dealing with X-rays, rather than visible light. It deals with focusing and other ways of manipulating the X-ray beams for research techniques such as X-ray diffraction, X-ray crystallography, X-ray fluorescence, small-angle X-ray scattering, X-ray microscopy, X-ray phase-contrast imaging, and X-ray astronomy.
X-rays and visible light are both electromagnetic waves, and propagate in space in the same way, but because of the much higher frequency and photon energy of X-rays they interact with matter very differently. Visible light is easily redirected using lenses and mirrors, but because the real part of the complex refractive index of all materials is very close to 1 for X-rays, they instead tend to initially penetrate and eventually get absorbed in most materials without significant change of direction.
No material has substantial reflection for X-rays, except at very small grazing angles. Multilayers enhance the small reflectivity from a single boundary by adding the small reflected amplitudes from many boundaries coherently in phase.
For example, if a single boundary has a reflectivity of R = 10 −4 (amplitude r = 10 −2 ), then the addition of 100 amplitudes from 100 boundaries can give reflectivity R close to one. The period Λ of the multilayer that provides the in-phase addition is that of the standing wave produced by the input and output beam, Λ = λ/2 sin θ, where λ is the wavelength, and 2θ the half angle between the two beams.
For θ = 90°, or reflection at normal incidence, the period of the multilayer is Λ = λ/2. The shortest period that can be used in a multilayer is limited by the size of the atoms to about 2 nm, corresponding to wavelengths above 4 nm. For shorter wavelength a reduction of the incidence angle θ toward more grazing has to be used.
The materials for multilayers are selected to give the highest possible reflection at each boundary and the smallest absorption or the propagation through the structure. This is usually achieved by light, low-density materials for the spacer layer and a heavier material that produces high contrast.
The absorption in the heavier material can be reduced by positioning it close to the nodes of the standing-wave field inside the structure. Good low-absorption spacer materials are Be, C, B, B 4 C and Si. Some examples of the heavier materials with good contrast are W, Rh, Ru and Mo.
Applications include: normal and grazing-incidence optics for telescopes from EUV to hard X-rays, microscopes, beam lines at synchrotron and FEL facilities, EUV lithography. Mo/Si is the material selection used for the near-normal incidence reflectors for EUV lithography.
Text derived from https://en.wikipedia.org/w/index.php?oldid=1301522725 under CC BY-SA 4.0; modifications have been made.