Zero Reference Model ==================== In Robotics engineering, Zero Reference Model (ZRM) is a method for describing the kinematics of a serial manipulator, alternative to the Denavit-Hartenberg parameters (DH). It was introduced by Gupta in 1981. with the name Zero Reference Position Description. Some authors claim that ZRM is superior to DH, for example in the case of geometric parameters calibration In Robotics engineering, Zero Reference Model (ZRM) is a method for describing the kinematics of a serial manipulator, alternative to the Denavit-Hartenberg parameters (DH). It was introduced by Gupta in 1981. with the name Zero Reference Position Description. Some authors claim that ZRM is superior to DH, for example in the case of geometric parameters calibration The joint direction as a vector u_0^i The joint center as a position Q_0^i The Hand Data as a position Q_0^h and two orthogonal vectors u_0^a (direction of gripping) and u_0^t (direction of the gripper tongs) The ZRM table for a simple serial manipulator with 6 joints is shown below: Joint nb i , joint type Joint dir u_0^i Joint pos Q_0^i Hand data 1, R (0, 0, 1) (0, 0, 0) Q_0^h = (b + c + d + e + f, 0, a) u_0^a = (1, 0, 0) u_0^t = (0, 0, 1) 2, R (0, 1, 0) (0, 0, a) 3, R (0, 1, 0) (b, 0, a) 4, R (1, 0, 0) (b + c, 0, a) 5, R (0, 1, 0) (b + c + d, 0, a) 6, R (1, 0, 0) (b + c + d + e, 0, a) The transformation of the hand with respect to the base is calculated as follows: [T] = [T_0^1].[T_1^2]...[T_{n-1}^n].[T_n^h] Each individual transformation T_{i-1}^i is the combination of the translation Q_{i-1}^i and the rotation R_{i-1}^i with: For a rotative joint: Q_{i-1}^i = Q_0^i - Q_0^{i-1} and R_{i-1}^i = Rot(q_i, u_0^i) For a prismatic joint: Q_{i-1}^i = (Q_0^i - Q_0^{i-1}) + q_i.u_0^i and R_{i-1}^i = Id The transformation [T_n^h] is given as: [T_n^h] = \begin{pmatrix} u_0^t \times u_0^a & u_0^t & u_0^a & Q_0^h - Q_0^n \\ 0 & 0 & 0 & 1 \end{pmatrix} It leads to simple calculations, especially when using unitary quaternions for the rotations, as R_i^j = cos(\frac{q_j}{2}) + sin(\frac{q_j}{2}).(u_{i0_x} i +u_{i0_y} j + u_{i0_z} k) A more compact form can be obtained by using Q_{i-1}^i instead of Q_0^i in the third column, and a position and quaternion in the fourth. The table above becomes: Joint nb i , joint type Joint dir u_{i-1}^i Joint pos Q_{i-1}^i Hand data 1, R (0, 0, 1) (0, 0, 0) Q_6^h = (f, 0, 0) R_6^h = Id 2, R (0, 1, 0) (0, 0, a) 3, R (0, 1, 0) (b, 0, 0) 4, R (1, 0, 0) (c, 0, 0) 5, R (0, 1, 0) (d, 0, 0) 6, R (1, 0, 0) (e, 0, 0) The ZRM of a serial manipulator can be described even if the manipulator cannot reach the zero value on all joints because of mechanical limitations. REFERENCES ---------- BIBLIOGRAPHY (BibTeX) -------------------- @article{ref0, title = {Zero Reference Model}, url = {https://encyclopegia.org/a/zero-reference-model} } BIBLIOGRAPHY (RIS) ------------------- TY - JOUR TI - Zero Reference Model UR - https://encyclopegia.org/a/zero-reference-model ER - CITE THIS ARTICLE ---------------- Cite this article: Zero Reference Model Derived from: https://en.wikipedia.org/w/index.php?oldid=1376271490 Licence: CC BY-SA 4.0 Snapshot: enwiki-001376271490 Permalink: /a/zero-reference-model