AFIB Technology
AFIB Technology (sometimes referred to as Microlife AFIB Technology) is a feature in sphygmomanometer devices that is designed to detect and monitor the incidence of atrial fibrillation in patients.[src] The technology was designed, patented, and is currently used by the Microlife Corporation.[src] It has been the subject of numerous medical studies and has been validated for in-home and clinical use.[src] It can be found in several Microlife devices, including the WatchBP Home A, BP A200 Plus, WatchBP Office, and WatchBP O3.[src]
AFIB Technology (sometimes referred to as Microlife AFIB Technology) is a feature in sphygmomanometer devices that is designed to detect and monitor the incidence of atrial fibrillation in patients.[src] The technology was designed, patented, and is currently used by the Microlife Corporation.[src] It has been the subject of numerous medical studies and has been validated for in-home and clinical use.[src] It can be found in several Microlife devices, including the WatchBP Home A, BP A200 Plus, WatchBP Office, and WatchBP O3.[src] ==Specifications== The Microlife devices that use the AFIB Technology are oscillometric and are equipped with an algorithm that can detect irregular pulse rhythms.[src] The device will flash if atrial fibrillation is detected.[src] Measurements are carried out in triplicate for more accurate readings.[src] Studies have confirmed the relative accuracy of such readings when attempting to identify the existence of atrial fibrillation in patients.[src] One study indicated that the Microlife blood pressure monitor had a sensitivity for detecting atrial fibrillation of 100%, a specificity of 92%.[src] Several clinical studies have tested the Microlife AFIB Technology against 12-lead electrocardiography (ECG) interpreted by cardiologists.[src] The sensitivity for detection in these studies varied between 95 and 100% with specificity values of 89 to 92%.[src] One study noted that the WatchBP device was better for detecting atrial fibrillation than single-lead ECGs because of its higher specificity level (90 vs 76%, respectively), which would prevent many unnecessary refers for a 12-lead ECG and therefore safes labor and healthcare costs.[src] In addition, it does not require clinical interpretation.[src] In virtually every study, researchers have concluded that Microlife's AFIB Technology is suitable for use as an atrial fibrillation detection system for in-home and/or clinical purposes.[src] In 2013, the UK National Institute for Health and Care Excellence recommended the WatchBP Home A device for routine blood pressure measurement and atrial fibrillation screening in primary care.[src] The recommendation is based on the NICE conclusion that use of WatchBP Home A in primary care is associated with estimated overall cost savings per person measured, ranging from £2.98 for those aged between 65 and 74 years to £4.26 for those aged 75 years and over.[src] ==Patents== Detecting atrial fibrillation, method of and apparatus for filed February 17, 2006; issued April 27, 2010 Detecting atrial fibrillation, method of and apparatus for filed February 15, 2006; issued March 16, 2010 Method of and apparatus for detecting atrial fibrillation filed November 27, 2002; issued March 28, 2006 Method of and apparatus for detecting arrhythmia and fibrillation filed December 20, 1999; issued February 11, 2003 ==References== ==External links== Microlife AFIB Technology[src]
21 sentences · 21 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"AFIB Technology." encyclopegia.org, 2026, https://encyclopegia.org/wiki/afib-technology. Accessed 28 November 2026.
Chicago
"AFIB Technology." encyclopegia.org. Accessed November 28, 2026. https://encyclopegia.org/wiki/afib-technology.
APA
encyclopegia.org. (2026). AFIB Technology. Retrieved November 28, 2026, from https://encyclopegia.org/wiki/afib-technology
Accessed November 28, 2026 · CC BY-SA 4.0 · citation page · JSON