Ames test
The Ames test is a widely employed method that uses bacteria to test whether a given chemical can cause mutations in the DNA of the test organism. More formally, it is a biological assay to assess the mutagenic potential of chemical compounds. A positive test indicates that the chemical is mutagenic and therefore may act as a carcinogen, because cancer is often linked to mutation. The test serves as a quick and convenient assay to estimate the carcinogenic potential of a compound because standard carcinogen assays on mice and rats are time-consuming (taking two to three years to complete) and expensive. However, false-positives and false-negatives are known. The procedure was described in a series of papers in the early 1970s by Bruce Ames and his group at the University of California, Berkeley.
The Ames test is a widely employed method that uses bacteria to test whether a given chemical can cause mutations in the DNA of the test organism. More formally, it is a biological assay to assess the mutagenic potential of chemical compounds. A positive test indicates that the chemical is mutagenic and therefore may act as a carcinogen, because cancer is often linked to mutation. The test serves as a quick and convenient assay to estimate the carcinogenic potential of a compound because standard carcinogen assays on mice and rats are time-consuming (taking two to three years to complete) and expensive. However, false-positives and false-negatives are known. The procedure was described in a series of papers in the early 1970s by Bruce Ames and his group at the University of California, Berkeley. ==Ames test and carcinogens== Mutagens identified via Ames test are also possible carcinogens, and early studies by Ames showed that 90% of known carcinogens may be identified via this test. Later studies however showed identification of 50–70% of known carcinogens. The test was used to identify a number of compounds previously used in commercial products as potential carcinogens. Examples include tris(2,3-dibromopropyl)phosphate, which was used as a flame retardant in plastic and textiles such as children's sleepwear, and furylfuramide which was used as an antibacterial additive in food in Japan in the 1960s and 1970s. Furylfuramide in fact had previously passed animal tests, but more vigorous tests after its identification in the Ames test showed it to be carcinogenic. Their positive tests resulted in those chemicals being withdrawn from use in consumer products. One interesting result from the Ames test is that the dose response curve using varying concentrations of the chemical is almost always linear, indicating that there is no threshold concentration for mutagenesis. It therefore suggests that, as with radiation, there may be no safe threshold for chemical mutagens or carcinogens. However, some have proposed that organisms could tolerate low levels of mutagens due to protective mechanisms such as DNA repair, and thus a threshold may exist for certain chemical mutagens. Bruce Ames himself argued against linear dose-response extrapolation from the high dose used in carcinogenesis tests in animal systems to the lower dose of chemicals normally encountered in human exposure, as the results may be false positives due to mitogenic response caused by the artificially high dose of chemicals used in such tests. He also cautioned against the "hysteria over tiny traces of chemicals that may or may not cause cancer", that "completely drives out the major risks you should be aware of". The Ames test is often used as one of the initial screens for potential drugs to weed out possible carcinogens, and it is one of the eight tests required under the Pesticide Act (USA) and one of the six tests required under the Toxic Substances Control Act (USA). ==Limitations== Salmonella typhimurium is a prokaryote, therefore it is not a perfect model for humans. Rat liver S9 fraction is used to mimic the mammalian metabolic conditions so that the mutagenic potential of metabolites formed by a parent molecule in the hepatic system can be assessed; however, there are differences in metabolism between humans and rats that can affect the mutagenicity of the chemicals being tested. The test may therefore be improved by the use of human liver S9 fraction; its use was previously limited by its availability, but it is now available commercially and therefore may be more feasible. An adapted in vitro model has been made for eukaryotic cells, for example yeast. Mutagens identified in the Ames test need not necessarily be carcinogenic, and further tests are required for any potential carcinogen identified in the test. Drugs that contain the nitrate moiety sometimes come back positive for Ames when they are indeed safe. The nitrate compounds may generate nitric oxide, an important signal molecule that can give a false positive. Nitroglycerin is an example that gives a positive Ames yet is still used in treatment today. Nitrates in food however may be reduced by bacterial action to nitrites which are known to generate carcinogens by reacting with amines and amides. Long toxicology and outcome studies are needed with such compounds to disprove a positive Ames test. ==Fluctuation method== The Ames test was initially developed using agar plates (the plate incorporation technique), as described above. Since that time, an alternative to performing the Ames test has been developed, which is known as the "fluctuation method". This technique is the same in concept as the agar-based method, with bacteria being added to a reaction mixture with a small amount of histidine, which allows the bacteria to grow and mutate, returning to synthesize their own histidine. By including a pH indicator, the frequency of mutation is counted in microplates as the number of wells which have changed color (caused by a drop in pH due to metabolic processes of reproducing bacteria). As with the traditional Ames test, the sample is compared to the natural background rate of reverse mutation in order to establish the genotoxicity of a substance. The fluctuation method is performed entirely in liquid culture and is scored by counting the number of wells that turn yellow from purple in 96-well or 384-well microplates. In the 96-well plate method the frequency of mutation is counted as the number of wells out of 96 which have changed color. The plates are incubated for up to five days, with mutated (yellow) colonies being counted each day and compared to the background rate of reverse mutation using established tables of significance to determine the significant differences between the background rate of mutation and that for the tested samples. In the more scaled-down 384-well plate microfluctuation method the frequency of mutation is counted as the number of wells out of 48 which have changed color after 2 days of incubation. A test sample is assayed across 6 dose levels with concurrent zero-dose (background) and positive controls which all fit into one 384-well plate. The assay is performed in triplicates to provide statistical robustness. It uses the recommended OECD Guideline 471 tester strains (histidine auxotrophs and tryptophan auxotrophs). The fluctuation method is comparable to the traditional pour plate method in terms of sensitivity and accuracy, however, it does have a number of advantages: it needs less test sample, it has a simple colorimetric endpoint, counting the number of positive wells out of possible 96 or 48 wells is much less time-consuming than counting individual colonies on an agar plate. Several commercial kits are available. Most kits have consumable components in a ready-to-use state, including lyophilized bacteria, and tests can be performed using multichannel pipettes. The fluctuation method also allows for testing higher volumes of aqueous samples (up to 75% v/v), increasing the sensitivity and extending its application to low-level environmental mutagens.
References
No reference rows published for this article.
Cite this article
MLA
"Ames test." encyclopegia.org, 2025, https://encyclopegia.org/wiki/ames-test. Accessed 24 November 2026.
Chicago
"Ames test." encyclopegia.org. Accessed November 24, 2026. https://encyclopegia.org/wiki/ames-test.
APA
encyclopegia.org. (2025). Ames test. Retrieved November 24, 2026, from https://encyclopegia.org/wiki/ames-test
Accessed November 24, 2026 · CC BY-SA 4.0 · citation page · JSON