Automatic exposure control
and three AEC regions (represented by dark grey circles and square) These regions represent anatomical areas, e.g.[src] lungs, spine.[src] They can be selected individually, or all at once depending on the need.[src] Automatic Exposure Control (AEC) is an X-ray exposure termination device.[src] A medical radiographic exposure is always initiated by a human operator but an AEC detector system may be used to terminate the exposure when a predetermined amount of radiation has been received.[src] The intention of AEC is to provide consistent X-ray image exposure, whether to film, a digital detector or a CT scanner.[src] AEC systems may also automatically set exposure factors such as the X-ray tube current and voltage in a CT.[src]
and three AEC regions (represented by dark grey circles and square) These regions represent anatomical areas, e.g.[src] lungs, spine.[src] They can be selected individually, or all at once depending on the need.]] Automatic Exposure Control (AEC) is an X-ray exposure termination device.[src] A medical radiographic exposure is always initiated by a human operator but an AEC detector system may be used to terminate the exposure when a predetermined amount of radiation has been received.[src] The intention of AEC is to provide consistent X-ray image exposure, whether to film, a digital detector or a CT scanner.[src] AEC systems may also automatically set exposure factors such as the X-ray tube current and voltage in a CT.[src] ==Operation== ===Projectional radiography=== In projectional radiography, an AEC system uses one or more physically thin radiation ionization chambers (the "AEC detector") positioned between the X-ray source and X-ray receptor.[src] Where low energy X-rays are used, such as in mammography, the AEC detector is placed behind the image receptor to avoid creating a shadow.[src] In early radiographic AEC systems, a large paddle (17" x 17") of transparent Lucite was sandwiched between rare earth screens, which emitted photons when excited by X-rays.[src] The individual Lucite sections were open on one end, and a solenoid was used to select one of three, or a combination of shutters that allowed the generated light into a photomultiplier tube (PMT).[src] The output of the PMT was then converted to a signal, which ramped in the positive direction until a preprogrammed threshold was reached.[src] At this point, the X-ray generator terminated the exposure.[src] This method is no longer used, and has been replaced by the iontomat.[src] In an iontomat, a weak ionization signal resulting from the radiographic X-rays passing through it are integrated as a ramp shaped voltage waveform.[src] This ramp signal rises until it matches a pre-set threshold.[src] At this point the X-ray exposure is terminated by the X-ray generator.[src] AEC devices are calibrated to ensure that similar exams have linearity in optical density.[src] ===Computed tomography=== Modern computed tomography (CT) scanners have AEC systems which aim to maintain image quality for patients of varying sizes, whilst keeping doses as low as reasonably practicable.[src] The systems are also designed to maintain quality with the varying size and attenuation of an individual patient over their length.[src] Implementations vary between manufacturers; some systems are based on a desired noise level in the image, while others are based on a specified reference output (milliampere second, mAs).[src] CT AEC systems use the initial "scanogram", a fixed angle planning view, to determine the relative size of the patient, and variation over their length.[src] The tube output is then adjusted for overall size.[src] The output is also typically modulated for each rotation in response to changes in attenuation over patient length.[src] Some systems adjust output during each rotation, which is known as rotational modulation, based on measured attenuation in the previous rotation.[src] ==Advantages== Because patients vary in size and shape, an AEC device is very useful in achieving consistent X-ray film densities, which can be difficult when manually setting exposure factors without AEC.[src] ==Disadvantages== AEC devices are susceptible to operator error (usually due to mispositioned anatomy or having the incorrect AEC chamber selected).[src] Prosthetic devices such as total hip hardware can also cause the selected ionization chamber to overexpose the image receptor.[src] This is due to the absorption of the X-ray beam into the metal of the hardware as opposed to exposing the ionization chamber.[src] ==References== ==Further reading==[src]
36 sentences · 36 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"Automatic exposure control." encyclopegia.org, 2025, https://encyclopegia.org/wiki/automatic-exposure-control. Accessed 27 November 2026.
Chicago
"Automatic exposure control." encyclopegia.org. Accessed November 27, 2026. https://encyclopegia.org/wiki/automatic-exposure-control.
APA
encyclopegia.org. (2025). Automatic exposure control. Retrieved November 27, 2026, from https://encyclopegia.org/wiki/automatic-exposure-control
Accessed November 27, 2026 · CC BY-SA 4.0 · citation page · JSON