Automatic fire suppression
Automatic fire suppression systems control and extinguish fires without human intervention.[src] Examples of automatic systems include fire sprinkler system, gaseous fire suppression, and condensed aerosol fire suppression.[src] When fires are extinguished in the early stages loss of life is minimal since 93% of all fire-related deaths occur once the fire has progressed beyond the early stages.[src]
Automatic fire suppression systems control and extinguish fires without human intervention.[src] Examples of automatic systems include fire sprinkler system, gaseous fire suppression, and condensed aerosol fire suppression.[src] When fires are extinguished in the early stages loss of life is minimal since 93% of all fire-related deaths occur once the fire has progressed beyond the early stages.[src] ==Components== By definition, an automatic fire suppression system can operate without human intervention.[src] To do so it must possess a means of detection, actuation and delivery.[src] In many systems, detection is accomplished by mechanical or electrical means.[src] Mechanical detection uses fusible-link or thermo-bulb detectors.[src] These detectors are designed to separate at a specific temperature and release tension on a release mechanism.[src] Electrical detection uses heat detectors equipped with self-restoring, normally-open contacts which close when a predetermined temperature is reached.[src] Remote and local manual operation is also possible.[src] Actuation usually involves either a pressurized fluid and a release valve, or in some cases an electric pump.[src] Delivery is accomplished by means of piping and nozzles.[src] Nozzle design is specific to the agent used and coverage desired.[src] ==Extinguishing agents== Water is the most prevalent fire suppression agent in use worldwide.[src] However, the use of water does have some limitations, which can range from inadequate supplies (particularly in less developed regions) to operations and processes which are highly susceptible to water damage.[src] In some cases, certain contents or processes (such as water-reactive chemicals or metals, molten materials, etc.) are truly incompatible with water; water discharge could lead to explosion.[src] In these instances, alternative chemical compounds, inert gases and similar can be utilized for fire suppression as outlined below: ==Health and environmental concerns== Despite their effectiveness, chemical fire extinguishing agents are not without disadvantages.[src] In the early 20th century, carbon tetrachloride was extensively used as a dry cleaning solvent, a refrigerant and as a fire extinguishing agent.[src] In time, it was found carbon tetrachloride could lead to severe health effects.[src] From the mid-1960s Halon 1301 was the industry standard for protecting high-value assets from the threat of fire.[src] Halon 1301 had many benefits as a fire suppression agent; it is fast-acting, safe for assets and required minimal storage space.[src] Halon 1301's major drawbacks are that it depletes atmospheric ozone and is potentially harmful to humans.[src] Since 1987, some 191 nations have signed The Montreal Protocol on Substances That Deplete the Ozone Layer.[src] The Protocol is an international treaty designed to protect the ozone layer by phasing out the production of a number of substances believed to be responsible for ozone depletion.[src] Among these were halogenated hydrocarbons often used in fire suppression.[src] As a result, manufacturers have focused on alternatives to Halon 1301 and Halon 1211 (halogenated hydrocarbons).[src] A number of countries have also taken steps to mandate the removal of installed Halon systems.[src] Most notably these include Germany and Australia, the first two countries in the world to require this action.[src] In both of these countries complete removal of installed Halon systems has been completed except for a very few essential-use applications.[src] The European Union is currently undergoing a similar mandated removal of installed Halon systems.[src] ==History== The first fire extinguisher patent was issued to Alanson Crane of Virginia on Feb.[src] 10, 1863.[src] The first fire sprinkler system was patented by H.W.[src] Pratt in 1872.[src] But the first practical automatic sprinkler system was invented in 1874 by Henry S.[src] Parmalee of New Haven, CT.[src] He installed the system in a piano factory he owned.[src] ==Modern systems== Since the early 1990s manufacturers have successfully developed safe and effective Halon alternatives.[src] These include DuPont's FM-200, American Pacific's Halotron, FirePro's FPC Compound, Plumis’ Automist and 3M's Novec 1230 Fire Protection Fluid.[src] Generally, the Halon replacement agents available today fall into two broad categories, in-kind (gaseous extinguishing agents) or not in-kind (alternative technologies).[src] In-kind gaseous agents generally fall into two further categories, halocarbons and inert gases.[src] Not in-kind alternatives include such options as water mist or the use of early warning smoke detection systems.[src] ==References== ==External links== Substitutes in Total Flooding Agents Automatic Fire Extinguishers and It’s Importance for Home Kitchens[src]
46 sentences · 46 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"Automatic fire suppression." encyclopegia.org, 2026, https://encyclopegia.org/wiki/automatic-fire-suppression. Accessed 26 November 2026.
Chicago
"Automatic fire suppression." encyclopegia.org. Accessed November 26, 2026. https://encyclopegia.org/wiki/automatic-fire-suppression.
APA
encyclopegia.org. (2026). Automatic fire suppression. Retrieved November 26, 2026, from https://encyclopegia.org/wiki/automatic-fire-suppression
Accessed November 26, 2026 · CC BY-SA 4.0 · citation page · JSON