Bomab
The BOttle MAnnequin ABsorber imaging phantom was developed by F.[src] Bush in 1949, and has since been accepted in North America as the industry standard for calibrating whole-body counting systems.[src] The phantom consists of 10 polyethylene bottles, either cylinders or elliptical cylinders, that represent the head, neck, chest, abdomen, thighs, calves, and arms.[src] Each section is filled with a radioactive solution, in water, that has the amount of radioactivity proportional to the volume of each section.[src] This simulates a homogeneous (even) distribution of material throughout the body.[src] The solution will also be acidified and contain a stable element carrier so that the radioactivity does not plate out on the container walls.[src] The phantom, which contains a known amount of radioactivity can be used to calibrate the whole body counter by relating the observed response to the known amount of radioactivity.[src] Because different radioactive materials emit different energies of gamma photons, the calibration has to be repeated to cover the expected energy range: usually 120 to 2,000 keV.[src] Examples of radioactive isotopes that are used for efficiency calibration include cobalt-57, cobalt-60, yttrium-88, caesium-137, and europium-152.[src] Although the phantom was designed to be used lying down, it can be used in any orientation.…[src]
The BOttle MAnnequin ABsorber imaging phantom was developed by F.[src] Bush in 1949, and has since been accepted in North America as the industry standard for calibrating whole-body counting systems.[src] The phantom consists of 10 polyethylene bottles, either cylinders or elliptical cylinders, that represent the head, neck, chest, abdomen, thighs, calves, and arms.[src] Each section is filled with a radioactive solution, in water, that has the amount of radioactivity proportional to the volume of each section.[src] This simulates a homogeneous (even) distribution of material throughout the body.[src] The solution will also be acidified and contain a stable element carrier so that the radioactivity does not plate out on the container walls.[src] The phantom, which contains a known amount of radioactivity can be used to calibrate the whole body counter by relating the observed response to the known amount of radioactivity.[src] Because different radioactive materials emit different energies of gamma photons, the calibration has to be repeated to cover the expected energy range: usually 120 to 2,000 keV.[src] Examples of radioactive isotopes that are used for efficiency calibration include cobalt-57, cobalt-60, yttrium-88, caesium-137, and europium-152.[src] Although the phantom was designed to be used lying down, it can be used in any orientation.[src] There are also several variations of the BOMAB with different proportions, designed to simulate women, children, and variations in body fat percentage.[src] ==Other uses== Phantoms can be used to evaluate the relative effect of size, shape, and positioning on the performance of in vivo measurement equipment.[src] A water-filled BOMAB is often used to estimate the (blank) background for in vivo assay systems.[src] A BOMAB filled with approximately 140 g of potassium-40, which is the nominal content in a 70 kg man, is sometimes used to estimate detection sensitivity of in vivo personnel counting systems.[src] BOMAB phantoms are sometimes used by performance testing organizations to test operating assay facilities.[src] Phantoms containing known quantities of radioactive material are sent to assay facilities as blind samples.[src] ==See also== Computational human phantom Imaging phantom ==References==[src]
27 sentences · 27 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"Bomab." encyclopegia.org, 2026, https://encyclopegia.org/wiki/bomab. Accessed 25 November 2026.
Chicago
"Bomab." encyclopegia.org. Accessed November 25, 2026. https://encyclopegia.org/wiki/bomab.
APA
encyclopegia.org. (2026). Bomab. Retrieved November 25, 2026, from https://encyclopegia.org/wiki/bomab
Accessed November 25, 2026 · CC BY-SA 4.0 · citation page · JSON