Busbar
copper busbars within a power distribution rack for a large building In electric power distribution, a busbar (also bus bar) is a metallic strip or bar, typically housed inside switchgear, panel boards, and busway enclosures for local high current power distribution, transmission, or switching substations.[src] They are also used to connect high voltage equipment at electrical switchyards, and low-voltage equipment in battery banks.[src] They are generally uninsulated, and have sufficient stiffness to be supported in air by insulated pillars.[src] Those features allow sufficient cooling of the conductors, and the ability to tap in at various points without having to create a new joint.[src]
copper busbars within a power distribution rack for a large building]] In electric power distribution, a busbar (also bus bar) is a metallic strip or bar, typically housed inside switchgear, panel boards, and busway enclosures for local high current power distribution, transmission, or switching substations.[src] They are also used to connect high voltage equipment at electrical switchyards, and low-voltage equipment in battery banks.[src] They are generally uninsulated, and have sufficient stiffness to be supported in air by insulated pillars.[src] Those features allow sufficient cooling of the conductors, and the ability to tap in at various points without having to create a new joint.[src] ==Design and placement== The busbar's material composition and cross-sectional size determine the maximum current it can safely carry.[src] Busbars can have a cross-sectional area of as little as , but electrical substations may use metal tubes in diameter or more as busbars.[src] Aluminium smelters use very large busbars to carry tens of thousands of amperes to the electrochemical cells that produce aluminium from molten salts.[src] Busbars are produced in a variety of shapes, including flat strips, solid bars and rods, and are typically composed of copper, brass or aluminium as solid or hollow tubes.[src] Some of these shapes allow heat to dissipate more efficiently due to their high surface area to cross-sectional area ratio.[src] The skin effect makes 50–60 Hz AC busbars more than about thickness inefficient, so hollow or flat shapes are prevalent in higher-current applications.[src] A hollow section also has higher stiffness than a solid rod of equivalent current-carrying capacity, which allows a greater span between busbar supports in outdoor electrical switchyards.[src] A busbar must be sufficiently rigid to support its own weight, and forces imposed by mechanical vibration and possibly earthquakes, as well as accumulated precipitation in outdoor exposures.[src] In addition, thermal expansion from temperature changes induced by ohmic heating and ambient temperature variations, and magnetic forces induced by large currents, must be considered.[src] To address these concerns, flexible bus bars, typically a sandwich of thin conductor layers, were developed.[src] They require a structural frame or cabinet for their installation.[src] Mechanical forces generated by fault currents, which can momentarily reach hundreds of thousands of amperes, must also be considered.[src] Distribution boards split the electrical supply into separate circuits at one location.[src] Busways, or bus ducts, are long busbars with protective covers.[src] Rather than branching from the main supply at one location, they allow new circuits to branch off anywhere along the busway.[src] A busbar may be either supported on insulators, or wrapped in insulation.[src] They are protected from accidental contact either by a metal earthed enclosure or by elevation out of normal reach.[src] Insulated bus bars are used in busways listed to UL 857 standards.[src] Power neutral busbars may also be insulated because it is not guaranteed that the potential between power neutral and safety grounding is always zero.[src] Earthing (safety grounding) busbars are typically bare and bolted directly onto any metal chassis of their enclosure.[src] They may be enclosed in a metal housing, in the form of a bus duct or busway, segregated-phase bus, or isolated-phase bus.[src] Busbars may be connected to each other and to electrical apparatus by bolting, clamping or welding.[src] Joints between high-current bus sections often have precisely machined matching surfaces that are silver-plated to reduce contact resistance.[src] At extra high voltages (more than 300 kV) in outdoor buses, corona discharge around the connections becomes a source of radio-frequency interference and power loss, so special connection fittings designed for those voltages are used.[src] UW_Ebingen_Sammelschienen.jpg|flexible busbar Kändelweg Sammelschienen.jpg|rigid busbar ==See also== ==References== ==Further reading==[src]
33 sentences · 33 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"Busbar." encyclopegia.org, 2025, https://encyclopegia.org/wiki/busbar. Accessed 25 November 2026.
Chicago
"Busbar." encyclopegia.org. Accessed November 25, 2026. https://encyclopegia.org/wiki/busbar.
APA
encyclopegia.org. (2025). Busbar. Retrieved November 25, 2026, from https://encyclopegia.org/wiki/busbar
Accessed November 25, 2026 · CC BY-SA 4.0 · citation page · JSON