encyclopegia.org

CAP1400

The CAP1400, later renamed Guohe One, is a Chinese Generation III+ reactor Pressurized water reactor developed by the State Power Investment Corporation.[src] It was based on Westinghouse AP1000 design but with full Chinese intellectual property rights.[src]

The CAP1400, later renamed Guohe One, is a Chinese Generation III+ reactor Pressurized water reactor developed by the State Power Investment Corporation.[src] It was based on Westinghouse AP1000 design but with full Chinese intellectual property rights.[src] ==Design== The CAP-1400 is a Pressurized water reactor, in which the primary coolant water is pumped under high pressure to the reactor core where it is heated by the energy released by the fission of atoms.[src] CAP1400 has two primary coolant loops that transfer the heat generated by the fission reaction of 235U in the reactor core to the steam generator, each loop consists of a hot leg, two cold legs, one steam generator, and two canned pumps.[src] CAP1400 has one pressurizer (PRZ) connected to one of the hot legs by a surge line.[src] The fuel core of the reactor has 193 fuel assemblies.[src] The safety systems are fully passive driven, mainly by gravity.[src] CAP-1400 has a design life of 60 years, and has refueling interval of 18 months, and averaged discharge fuel burnup of ≥50,000 MWd⋅(tU) −1 .[src] The system operated pressure is 15.5Mpa, and coolant average temperature is 304 °C, while steam pressure at steam generator is 6.01Mpa.[src] The steam flow at steam generator is around 1123.4 kg⋅s −1 .[src] CAP1400 has a compact and general layout.[src] It covers area of only 0.164 m 2 ·kW −1 , which is less than AP1000.[src] Estimated cost of the CAP-1400 is around 16,000 CNY⋅kW −1 ($2443 USD⋅kW −1 / $3800 USD⋅kW −1 PPP).[src] In February 2019, the Shanghai Nuclear Engineering Research & Design Institute announced that it had begun the conceptual design process for the CAP-1700 based on CAP-1400.[src] The CAP-1400 project may extend to a larger, three-loop CAP-2100 design if the passive cooling system can be scaled to that level.[src] ==Power Plants== ==References== ==Sources==[src]

18 sentences · 18 cited inline · 0 references stored

References

No reference rows published for this article.

Cite this article

MLA

"CAP1400." encyclopegia.org, 2026, https://encyclopegia.org/wiki/cap1400. Accessed 26 November 2026.

Chicago

"CAP1400." encyclopegia.org. Accessed November 26, 2026. https://encyclopegia.org/wiki/cap1400.

APA

encyclopegia.org. (2026). CAP1400. Retrieved November 26, 2026, from https://encyclopegia.org/wiki/cap1400

Accessed November 26, 2026 · CC BY-SA 4.0 · citation page · JSON

Claims

PredicateValueSource
area0.164 mWikipedia
CC BY-SA 4.0 · share-alike · https://en.wikipedia.org/w/index.php?oldid=1368911102 · 0.5 · snapshot enwiki-001368911102

Cite · JSON · Search

Related services and records

Services

  • Estate — measured countries, lanes and facts
  • Intel — live corroborated events
  • Legal — statutes, cases and citations
  • Encyclopedia — articles with inline sources
  • Space — launches, satellites and orbits
  • Search — federated search and reports
  • Pass — passport account and SSO
  • Corpora — read-only corpus origins
  • e01 — self-hosted corpora and tools

Text and metadata only; each target carries its own sources. Missing data is published as no-data, never estimated.