encyclopegia.org

Captive bubble method

The captive bubble method is a method for measuring the contact angle between a liquid and a solid, by using drop shape analysis. In this method, a bubble of air is injected beneath a solid, the surface of which is located in the liquid, instead of placing a drop on the solid as in the case of the sessile drop technique. A liquid and a solid are replaced by using drop shape analysis. The method is particularly suitable for solids with high surface energy, where liquids spread out. Hydrogels, such as those that comprise soft contact lenses, are inaccessible to the standard arrangement; so the captive bubble method is also used in such cases. A contact angle is formed on a smooth, periodically heterogeneous solid surface. Above the solid surface, a liquid drop is submerged in a fluid. The measurement of contact angles usually contributes to the measurement of the surface energy of solids in the industry. Different from other methods of measuring the contact angle, such as the sessile drop technique, the system utilized in the captive bubble method has the fluid bubble attached from below to the solid surface, such that both the liquid bubble and the solid interact with a fluid.

The captive bubble method is a method for measuring the contact angle between a liquid and a solid, by using drop shape analysis. In this method, a bubble of air is injected beneath a solid, the surface of which is located in the liquid, instead of placing a drop on the solid as in the case of the sessile drop technique. A liquid and a solid are replaced by using drop shape analysis. The method is particularly suitable for solids with high surface energy, where liquids spread out. Hydrogels, such as those that comprise soft contact lenses, are inaccessible to the standard arrangement; so the captive bubble method is also used in such cases. A contact angle is formed on a smooth, periodically heterogeneous solid surface. Above the solid surface, a liquid drop is submerged in a fluid. The measurement of contact angles usually contributes to the measurement of the surface energy of solids in the industry. Different from other methods of measuring the contact angle, such as the sessile drop technique, the system utilized in the captive bubble method has the fluid bubble attached from below to the solid surface, such that both the liquid bubble and the solid interact with a fluid. ==Application and significance== ==Comparisons between sessile drop technique and captive bubble method== The sessile drop method is another popular way to measure contact angles and is done by placing a two-dimensional drop on a solid surface and controlling the volume of liquid in the drop. The sessile drop method and the captive bubble method are usually interchangeable when performing experiments, as they are both based on the properties of symmetry. Specifically, the axis of symmetry of the drop or bubble makes the contact line of the drop or bubble with the solid surface circular. This creates an observable contact angle corresponding to the contact radius of the drop or bubble. However, interacting with a rough homogeneous surface in measurements of contact angles, the drop and bubble each present different behaviors in the measuring process, which are related to the volume of liquid and contact angles. On a rough homogeneous surface, the observed contact angle may not represent the actual contact angle with a local slope since it may not be observable on a rough surface. The observed contact angle on a rough surface is also called an apparent angle, which is equivalent to the sum of the intrinsic contact angle and the local surface slope at the tangent of the contact slope for a drop or bubble. With the sessile drop method, the observed contact angle usually underestimates the intrinsic contact angle, while the observed contact angle in the captive bubble method overestimates the intrinsic contact angle of the rough surface. If a graph is plotted, respectively, for the measurements of contact angles using the sessile drop method and the captive bubble method concerning the volume of liquid within the drop or bubble and the measured contact angle, the geometrical relationships illustrate different characteristics for each method. In consideration of the relationship between contact angles and the position of the contact for a certain volume in the drop or bubble, the highest and lowest possible contact angles on volume are dependent on each other differently in the two methods. For the amplitude of oscillations shown in the graph, both the drop and the captive bubble display a similar order of magnitude at a relatively low contact angle. On the other hand, on a rough surface with a relatively high contact angle, the amplitude shown for the drop is larger than that of a captive bubble. The amplitude of oscillation of the lowest and highest possible contact angle demonstrates the difference between the drop method and the captive bubble method, in which the amplitude of the graph of the captive bubble method is comparatively larger than that of the graph of the sessile drop method. In terms of the wavelength of the graph, the wavelength for both methods spans over a large range of volumes of liquid on the solid surface. Differences in the behavior of the drop and the bubble vary from the lowest possible contact angles to the highest possible contact angles. ==References==

References

No reference rows published for this article.

Cite this article

MLA

"Captive bubble method." encyclopegia.org, 2025, https://encyclopegia.org/wiki/captive-bubble-method. Accessed 24 November 2026.

Chicago

"Captive bubble method." encyclopegia.org. Accessed November 24, 2026. https://encyclopegia.org/wiki/captive-bubble-method.

APA

encyclopegia.org. (2025). Captive bubble method. Retrieved November 24, 2026, from https://encyclopegia.org/wiki/captive-bubble-method

Accessed November 24, 2026 · CC BY-SA 4.0 · citation page · JSON

CC BY-SA 4.0 · share-alike · https://en.wikipedia.org/w/index.php?oldid=1330217979 · 0.5 · snapshot enwiki-001330217979

Cite · JSON · Search

Related services and records

Services

  • Estate — measured countries, lanes and facts
  • Intel — live corroborated events
  • Legal — statutes, cases and citations
  • Encyclopedia — articles with inline sources
  • Space — launches, satellites and orbits
  • Search — federated search and reports
  • Pass — passport account and SSO
  • Corpora — read-only corpus origins
  • e01 — self-hosted corpora and tools

Text and metadata only; each target carries its own sources. Missing data is published as no-data, never estimated.