Chronoamperometry
showing integrated region for charge determination.[src] In electrochemistry, chronoamperometry is an analytical technique in which the electric potential of the working electrode is stepped and the resulting current from faradaic processes occurring at the electrode (caused by the potential step) is monitored as a function of time.[src] The functional relationship between current response and time is measured after applying single or double potential step to the working electrode of the electrochemical system.[src] Limited information about the identity of the electrolyzed species can be obtained from the ratio of the peak oxidation current versus the peak reduction current.[src] However, as with all pulsed techniques, chronoamperometry generates high charging currents, which decay exponentially with time as any RC circuit.[src] The Faradaic current - which is due to electron transfer events and is most often the current component of interest - decays as described in the Cottrell equation.[src] In most electrochemical cells, this decay is much slower than the charging decay-cells with no supporting electrolyte are notable exceptions.[src] Most commonly a three-electrode system is used.[src] Since the current is integrated over relatively longer time intervals, chronoamperometry gives a better signal-to-noise ratio in comparison to other amperometric techniques.…[src]
showing integrated region for charge determination.]] In electrochemistry, chronoamperometry is an analytical technique in which the electric potential of the working electrode is stepped and the resulting current from faradaic processes occurring at the electrode (caused by the potential step) is monitored as a function of time.[src] The functional relationship between current response and time is measured after applying single or double potential step to the working electrode of the electrochemical system.[src] Limited information about the identity of the electrolyzed species can be obtained from the ratio of the peak oxidation current versus the peak reduction current.[src] However, as with all pulsed techniques, chronoamperometry generates high charging currents, which decay exponentially with time as any RC circuit.[src] The Faradaic current - which is due to electron transfer events and is most often the current component of interest - decays as described in the Cottrell equation.[src] In most electrochemical cells, this decay is much slower than the charging decay-cells with no supporting electrolyte are notable exceptions.[src] Most commonly a three-electrode system is used.[src] Since the current is integrated over relatively longer time intervals, chronoamperometry gives a better signal-to-noise ratio in comparison to other amperometric techniques.[src] There are two types of chronoamperometry that are commonly used: controlled-potential chronoamperometry and controlled-current chronoamperometry.[src] Before running controlled-potential chronoamperometry, cyclic voltammetries are run to determine the reduction potential of the analytes.[src] Generally, chronoamperometry uses fixed-area electrodes, which are suitable for studying electrode processes of coupled chemical reactions, especially the reaction mechanism of organic electrochemistry.[src] ==Example== Anthracene in deoxygenated dimethylformamide (DMF) will be reduced (An + e − -> An − ) at the electrode surface that is at a certain negative potential.[src] The reduction will be diffusion-limited, thereby causing the current to drop in time (proportional to the diffusion gradient that is formed by diffusion).[src] You can do this experiment several times increasing electrode potentials from low to high.[src] (In between the experiments, the solution should be stirred.) When you measure the current i(t) at a certain fixed time point τ after applying the voltage, you will see that at a certain moment the current i(τ) does not rise anymore; you have reached the mass-transfer-limited region.[src] This means that anthracene arrives as fast as diffusion can bring it to the electrode.[src] i=\frac{nFAC\sqrt{D}}{\sqrt{t\pi}} where is the current in amps; is the number of electrons; is the Faraday constant; is the area of the planar electrode in cm 2 ; is the initial concentration of the analyte in mol/cm 3 ; is the diffusion coefficient for species in cm 2 /s; is the time in seconds.[src] Under controlled-diffusion circumstances, the current-time plot reflects the concentration gradient of the solution near the electrode surface.[src] The current is directly proportional to the concentration at the electrode surface.[src] In 1922, Jaroslav Heyrovský reiterated the chronoamperometric method when he invented the polarographic method.[src] It can use the basic circuit of the polarograph.[src] To connect the fast recorder or oscilloscope, the dropping mercury electrode is not used, instead, the static electrodes such as suspended mercury, mercury poll or platinum, gold and graphite are used.[src] In addition, the solution is not stirred.[src] In the presence of the inert electrolytes, the mass transfer process is mainly diffusion.[src] Jarroslav Herovsky derived the chronopotentiometric method from the Cottrell equation.[src] Chronopotentiometry is an electrochemical method that can generate a stable current that can flow between two different electrodes.[src] ==See also== Electroanalytical methods Electrochemical skin conductance Potentiometric titration Voltammetry ==References==[src]
36 sentences · 36 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"Chronoamperometry." encyclopegia.org, 2026, https://encyclopegia.org/wiki/chronoamperometry. Accessed 29 November 2026.
Chicago
"Chronoamperometry." encyclopegia.org. Accessed November 29, 2026. https://encyclopegia.org/wiki/chronoamperometry.
APA
encyclopegia.org. (2026). Chronoamperometry. Retrieved November 29, 2026, from https://encyclopegia.org/wiki/chronoamperometry
Accessed November 29, 2026 · CC BY-SA 4.0 · citation page · JSON