Common-path interferometer
A common-path interferometer is a class of interferometers in which the reference beam and sample beams travel along the same path. Examples include the Sagnac interferometer, Zernike phase-contrast interferometer, and the point diffraction interferometer. A common-path interferometer is generally more robust to environmental vibrations than a "double-path interferometer" such as the Michelson interferometer or the Mach–Zehnder interferometer. Although travelling along the same path, the reference and sample beams may travel along opposite directions, or they may travel along the same direction but with the same or different polarization. Double-path interferometers are highly sensitive to phase shifts or length changes between the reference and sample arms. Because of this, double-path interferometers have found wide use in science and industry for the measurement of small displacements, refractive-index changes, surface irregularities and the like. There are applications, however, in which sensitivity to relative displacement or refractive-index differences between reference and sample paths is not desirable; alternatively, one may be interested in the measurement of some other property.
A common-path interferometer is a class of interferometers in which the reference beam and sample beams travel along the same path. Examples include the Sagnac interferometer, Zernike phase-contrast interferometer, and the point diffraction interferometer. A common-path interferometer is generally more robust to environmental vibrations than a "double-path interferometer" such as the Michelson interferometer or the Mach–Zehnder interferometer. Although travelling along the same path, the reference and sample beams may travel along opposite directions, or they may travel along the same direction but with the same or different polarization. Double-path interferometers are highly sensitive to phase shifts or length changes between the reference and sample arms. Because of this, double-path interferometers have found wide use in science and industry for the measurement of small displacements, refractive-index changes, surface irregularities and the like. There are applications, however, in which sensitivity to relative displacement or refractive-index differences between reference and sample paths is not desirable; alternatively, one may be interested in the measurement of some other property. ==Selected examples== ===Sagnac=== Sagnac interferometers are fundamentally unsuited for measuring lengths or length changes. In such an interferometer, both beams emerging from the beamsplitter travel simultaneously around all four sides of a rectangular loop in opposite directions and recombine at the original beamsplitter. As a result, a Sagnac interferometer is, to first order, completely insensitive to any movement of its optical components. Indeed, to make the Sagnac interferometer useful for measuring phase changes, the counter‑propagating beams of the interferometer must be separated slightly so that they no longer follow a perfectly common path. Even with a slight beam separation, Sagnac interferometers offer excellent contrast and fringe stability. Two basic topologies of the Sagnac interferometer are possible, differing in whether there are an even or odd number of reflections in each path. In a Sagnac interferometer with an odd number of reflections, such as the one illustrated, the wavefronts of the oppositely traveling beams are laterally inverted with respect to each other over most of the light path, so the topology is not strictly common-path. The best known use of the Sagnac interferometer lies in its sensitivity to rotation. The first accounts of the effects of rotation on this form of interferometer were published in 1913 by Georges Sagnac, who mistakenly believed that his ability to detect a "whirling of the ether" disproved relativity theory. The sensitivity of present-day Sagnac interferometers far exceeds that of Sagnac's original arrangement. The sensitivity to rotation is proportional to the area circumscribed by the counter-rotating beams, and fibre optic gyroscopes, present-day descendants of the Sagnac interferometer, use thousands of loops of optical fibre rather than mirrors, such that even small to medium-sized units easily detect the rotation of the Earth. Ring laser gyroscopes (not illustrated) are another form of Sagnac rotation sensor that have important applications in inertial guidance systems. Because of their exceptional contrast and fringe stability, interferometers using the Sagnac configuration played an important role in experiments leading to Einstein's discovery of special relativity, and in the subsequent defense of relativity against theoretical and experimental challenges. For example, one year before their famous experiment of 1887, Michelson and Morley (1886) performed a repeat of the Fizeau experiment of 1851, replacing Fizeau's setup with an even-reflection Sagnac interferometer of such high stability, that even placing a lighted match in the light path did not cause artifactual fringe displacement. In 1935, Gustaf Wilhelm Hammar disproved a theoretical challenge to special relativity that attempted to explain away the null results of Michelson–Morley–type experiments as being mere artifact of aether-dragging, using an odd-reflection Sagnac interferometer. He could operate this interferometer in the open, on a high hilltop with no temperature control, yet still achieve readings of 1/10 fringe accuracy. ===Point diffraction=== Another common-path interferometer useful in lens testing and fluid flow diagnostics is the point diffraction interferometer (PDI), invented by Linnik in 1933. The reference beam is generated by diffraction from a small pinhole, about half the diameter of the Airy disk, in a semitransparent plate. Fig. 1 illustrates an aberrated wavefront focused onto the pinhole. The diffracted reference beam and the transmitted test wave interfere to form fringes. The common-path design of the PDI brings to it a number of important advantages. (1) Only a single laser path is required rather than the two paths required by the Mach-Zehnder or Michelson designs. This advantage can be very important in large interferometric setups such as in wind tunnels that have long optical paths through turbulent media. (2) The common-path design uses fewer optical components than double path designs, making alignment much easier, as well as reducing cost, size, and weight, especially for large setups. (3) While the accuracy of a double path design is dependent on the precision with which the reference element is figured, careful design enables the generated reference beam of the PDI to be of guaranteed precision. A disadvantage is that the amount of light getting through the pinhole depends on how well the light can be focused onto the pinhole. If the incident wavefront is severely aberrated, very little light may get through. The PDI has seen use in various adaptive optics applications. ===Lateral shearing=== Lateral shearing interferometry is a self-referencing method of wavefront sensing. Instead of comparing a wavefront with a separate path reference wavefront, lateral shearing interferometry interferes a wavefront with a shifted version of itself. As a result, it is sensitive to the slope of a wavefront, not the wavefront shape per se. The illustrated plane parallel plate interferometer has unequal path lengths for the test and reference beams; because of this, it must be used with highly monochromatic (laser) light. It is normally used without any coating on either surface, so as to minimize ghost reflections. An aberrated wavefront from a lens under test is reflected from the front and back of the plate to form the interference pattern. Variations on this basic design allow testing of mirrors. Other forms of lateral shearing interferometer, based on the Jamin, Michelson, Mach–Zehnder, and other interferometer designs, have compensated paths and may be used with white light. Besides optical testing, applications of lateral shearing interferometry have included thin film analysis, mass and thermal diffusion in transparent materials, refractive index and gradient of refractive index measurement, collimation testing, and adaptive optics. Shearing interferometers, a general framework which includes the lateral shearing, Hartmann, Shack–Hartmann, rotational shearing, folding shearing, and aperture masking interferometers, are used in most of the wavefront sensors industrially developed. ===Fresnel's biprism=== From the modern perspective, the result of Young's double slit experiment (see Fig. 2) clearly points towards the wave nature of light, but such was not the case in the early 1800s. Newton, after all, had observed what are now recognized as diffraction phenomena, and wrote on them in his Third Book of Optics, interpreting them in terms of his corpuscular theory of light. Young's contemporaries raised objections that his results could simply represent diffraction effects from the edges of the slits, no different in principle than the fringes that Newton had previously observed. Augustin Fresnel, who supported the wave theory, performed a series of experiments to demonstrate interference effects that could not be simply explained away as being the result of edge diffraction. The most notable of these was his use of a biprism to create two virtual interfering sources by refraction. An electron version of the Fresnel biprism is used in electron holography, an imaging technique that photographically records the electron interference pattern of an object. The hologram can then be illuminated by a laser resulting in a greatly magnified image of the original object, although the current preference is for numerical reconstruction of the holograms. This technique was developed to enable greater resolution in electron microscopy than is possible using conventional imaging techniques. The resolution of conventional electron microscopy is not limited by electron wavelength, but by the large aberrations of electron lenses. Fig. 3 shows the basic arrangement of an interference electron microscope. The electron biprism consists of a fine, positively charged electric filament (represented as a dot in the figure) bracketed by two plate electrodes at ground potential. The filament, generally not more than 1 μm in diameter, is usually a gold-coated quartz fiber. By placing the specimen off-axis in the electron beam, the diffracted specimen wavefront and the reference wavefront combine to create the hologram. ===Zero-area Sagnac=== The Laser Interferometer Gravitational-Wave Observatory (LIGO) consisted of two 4-km Michelson–Fabry–Pérot interferometers, and operated at a power level of about 100 watts of laser power at the beam splitter. A currently ongoing upgrade to Advanced LIGO will require several kilowatts of laser power, and scientists will need to contend with thermal distortion, frequency variation of the lasers, mirror displacement and thermally induced birefringence. A variety of competing optical systems are being explored for third generation enhancements beyond Advanced LIGO. One of these competing topologies has been the zero-area Sagnac design. As noted above, Sagnac interferometers are, to first order, insensitive to any static or low-frequency displacement of their optical components, nor are the fringes affected by minor frequency variation in the lasers or birefringence. A zero-area variant of the Sagnac interferometer has been proposed for third generation LIGO. Fig. 1 shows how by directing the light through two loops of opposite sense, an effective area of zero is obtained. This variant of the Sagnac interferometer is hence insensitive to rotation or low frequency drift of its optical components, while maintaining a high sensitivity to transient events of astronomical interest. However, many considerations are involved in the choice of an optical system, and despite the zero-area Sagnac's superiority in certain areas, there is as yet no consensus choice of optical system for third generation LIGO. ===Scatterplate=== A common path alternative to the Twyman–Green interferometer is the scatterplate interferometer, invented by J.M. Burch in 1953. The Twyman–Green interferometer, a double path interferometer, is a variant of the Michelson interferometer that is commonly used to test the precision of optical surfaces and lenses. Since reference and sample paths are divergent, this form of interferometer is extremely sensitive to vibration and to atmospheric turbulence in the light paths, both of which interfere with the optical measurements. Precision measurements of an optical surface are also extremely dependent on the quality of the auxiliary optics. Because the scatterplate interferometer is a common-path interferometer, the reference and test paths are automatically matched so that a zero order fringe can be easily obtained even with white light. It is relatively insensitive to vibration and turbulence, and the quality of the auxiliary optics is not as critical as in a Twyman-Green setup. Fringe contrast, however, is lower, and a characteristic hotspot may make the scatterplate interferometer unsuitable for various purposes. A variety of other common-path interferometers useful for optical testing have been described. Fig. 1 shows the interferometer set up to test a spherical mirror. A scatterplate is set near the center of curvature of the mirror under test. This plate has a pattern of tiny opaque patches which are arranged on the plate with inversion symmetry but which are otherwise random in shape and distribution. (1) A certain fraction of the light passes directly through the scatterplate, is reflected by the mirror, but then is scattered as it encounters the scatterplate for the second time. This direct-scattered light forms the reference beam. (2) A certain fraction of the light is scattered as it passes through the scatterplate, is reflected by the mirror, but then passes directly through the scatterplate as it encounters the scatterplate for the second time. This scattered-direct light forms the test beam, which combines with the reference beam to form interference fringes. (3) A certain fraction of the light passes directly through the scatterplate on both of its encounters. This direct-direct light generates a small, undesirable hotspot. (4) A certain fraction of the light is scattered on both encounters with the scatterplate. This scattered-scattered light lowers the overall contrast of the interference pattern. ===Bath Interferometer=== The Bath Interferometer (Fig. 4) can be used to test telescope mirrors. It usually consists of a beam splitter, an optical flat, a biconvex diverger of short focal length and a light source such as a semiconductor laser. ==Other configurations== Other common-path interferometer configurations have been described in the literature, such as the double-focus interferometer and the Saunders's prism interferometer, and many others. Common-path interferometers have proven useful in a wide variety of applications including optical coherence tomography, digital holography, and the measurement of phase delays. Their relative resilience to environmental vibration is a common outstanding feature, and they can sometimes be used when no reference beam is available; however, depending on their topology, their interference patterns may be more complicated to interpret than those generated by double path interferometers. ==See also== Double-path interferometer ==References==
References
- Multiple-wave lateral shearing interferometry for wave-front sensing · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Multiple-wave lateral shearing interferometry for wave-front sensing." Chanteloup, J. 2026-11-18. https://en.wikipedia.org/wiki/Bibcode_(identifier). Accessed 24 November 2026.
Chicago "Multiple-wave lateral shearing interferometry for wave-front sensing." Chanteloup, J. 2026-11-18. https://en.wikipedia.org/wiki/Bibcode_(identifier).
APA Chanteloup, J. (2026). Multiple-wave lateral shearing interferometry for wave-front sensing. Retrieved November 24, 2026, from https://en.wikipedia.org/wiki/Bibcode_(identifier)
- Measurement of small displacement based on surface plasmon resonance heterodyne interferometry · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Measurement of small displacement based on surface plasmon resonance heterodyne interferometry." Lin, Jiun-You; Chen, Kun-Huang; Chen, Jing-Heng (2011-07-01). 2026-11-18. https://en.wikipedia.org/wiki/Bibcode_(identifier). Accessed 24 November 2026.
Chicago "Measurement of small displacement based on surface plasmon resonance heterodyne interferometry." Lin, Jiun-You; Chen, Kun-Huang; Chen, Jing-Heng (2011-07-01). 2026-11-18. https://en.wikipedia.org/wiki/Bibcode_(identifier).
APA Lin, Jiun-You; Chen, Kun-Huang; Chen, Jing-Heng (2011-07-01). (2026). Measurement of small displacement based on surface plasmon resonance heterodyne interferometry. Retrieved November 24, 2026, from https://en.wikipedia.org/wiki/Bibcode_(identifier)
- Shearing interferometry for wavefront sensing · retrieved 2012-04-14 · rev 1365792551
Cite this reference
MLA "Shearing interferometry for wavefront sensing." Primot, J. 2012-04-14. https://web.archive.org/web/20120303055516/http://www.master-optics.eu/biblio/primot_guerineau.pdf. Accessed 24 November 2026.
Chicago "Shearing interferometry for wavefront sensing." Primot, J. 2012-04-14. https://web.archive.org/web/20120303055516/http://www.master-optics.eu/biblio/primot_guerineau.pdf.
APA Primot, J. (2012). Shearing interferometry for wavefront sensing. Retrieved November 24, 2026, from https://web.archive.org/web/20120303055516/http://www.master-optics.eu/biblio/primot_guerineau.pdf
- M. Lehmann, H. Lichte, Tutorial on off-axis electron holography, Microsc. Microanal. 8(6), 447–466 (2002) Wikipedia revision 1365792551, retrieved 2026-11-19 · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "M. Lehmann, H. Lichte, Tutorial on off-axis electron holography, Microsc. Microanal. 8(6), 447–466 (2002) Wikipedia revision 1365792551, retrieved 2026-11-19." M. 2026-11-18. https://en.wikipedia.org/w/index.php?oldid=1365792551. Accessed 24 November 2026.
Chicago "M. Lehmann, H. Lichte, Tutorial on off-axis electron holography, Microsc. Microanal. 8(6), 447–466 (2002) Wikipedia revision 1365792551, retrieved 2026-11-19." M. 2026-11-18. https://en.wikipedia.org/w/index.php?oldid=1365792551.
APA M. (2026). M. Lehmann, H. Lichte, Tutorial on off-axis electron holography, Microsc. Microanal. 8(6), 447–466 (2002) Wikipedia revision 1365792551, retrieved 2026-11-19. Retrieved November 24, 2026, from https://en.wikipedia.org/w/index.php?oldid=1365792551
- Common-path spectral interferometry with temporal carrier for highly sensitive surface plasmon resonance sensing · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Common-path spectral interferometry with temporal carrier for highly sensitive surface plasmon resonance sensing." Ng, Siu Pang; Loo, Fong Chuen; Wu, Shu Yuen; Kong, Siu Kai; Wu, Chi Man Lawrence; Ho, Ho Pui (2013-08-26). 2026-11-18. https://doi.org/10.1364%2FOE.21.020268. Accessed 24 November 2026.
Chicago "Common-path spectral interferometry with temporal carrier for highly sensitive surface plasmon resonance sensing." Ng, Siu Pang; Loo, Fong Chuen; Wu, Shu Yuen; Kong, Siu Kai; Wu, Chi Man Lawrence; Ho, Ho Pui (2013-08-26). 2026-11-18. https://doi.org/10.1364%2FOE.21.020268.
APA Ng, Siu Pang; Loo, Fong Chuen; Wu, Shu Yuen; Kong, Siu Kai; Wu, Chi Man Lawrence; Ho, Ho Pui (2013-08-26). (2026). Common-path spectral interferometry with temporal carrier for highly sensitive surface plasmon resonance sensing. Retrieved November 24, 2026, from https://doi.org/10.1364%2FOE.21.020268
- Ein Interferometer mit gemeinsamem Weg für Referenzstrahl und messtrahl (common path interferometer) · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Ein Interferometer mit gemeinsamem Weg für Referenzstrahl und messtrahl (common path interferometer)." DE patent 2300958 , Karl-Ludwig Bath, "Ein Interferometer mit gemeinsamem Weg für Referenzstrahl und messtrahl (common p. 2026-11-18. https://patents.google.com/patent/DE2300958A1/en?oq=de2300958. Accessed 24 November 2026.
Chicago "Ein Interferometer mit gemeinsamem Weg für Referenzstrahl und messtrahl (common path interferometer)." DE patent 2300958 , Karl-Ludwig Bath, "Ein Interferometer mit gemeinsamem Weg für Referenzstrahl und messtrahl (common p. 2026-11-18. https://patents.google.com/patent/DE2300958A1/en?oq=de2300958.
APA DE patent 2300958 , Karl-Ludwig Bath, "Ein Interferometer mit gemeinsamem Weg für Referenzstrahl und messtrahl (common p. (2026). Ein Interferometer mit gemeinsamem Weg für Referenzstrahl und messtrahl (common path interferometer). Retrieved November 24, 2026, from https://patents.google.com/patent/DE2300958A1/en?oq=de2300958
- Sagnac effect · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Sagnac effect." a b Anderson, R. 2026-11-18. http://signallake.com/innovation/andersonNov94.pdf. Accessed 24 November 2026.
Chicago "Sagnac effect." a b Anderson, R. 2026-11-18. http://signallake.com/innovation/andersonNov94.pdf.
APA a b Anderson, R. (2026). Sagnac effect. Retrieved November 24, 2026, from http://signallake.com/innovation/andersonNov94.pdf
- Scatter fringes of equal thickness · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Scatter fringes of equal thickness." Burch, J. 2026-11-18. https://en.wikipedia.org/wiki/Bibcode_(identifier). Accessed 24 November 2026.
Chicago "Scatter fringes of equal thickness." Burch, J. 2026-11-18. https://en.wikipedia.org/wiki/Bibcode_(identifier).
APA Burch, J. (2026). Scatter fringes of equal thickness. Retrieved November 24, 2026, from https://en.wikipedia.org/wiki/Bibcode_(identifier)
- Common-Path Interferometer for Testing Purposes · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Common-Path Interferometer for Testing Purposes." Dyson, J. 2026-11-18. https://en.wikipedia.org/wiki/Bibcode_(identifier). Accessed 24 November 2026.
Chicago "Common-Path Interferometer for Testing Purposes." Dyson, J. 2026-11-18. https://en.wikipedia.org/wiki/Bibcode_(identifier).
APA Dyson, J. (2026). Common-Path Interferometer for Testing Purposes. Retrieved November 24, 2026, from https://en.wikipedia.org/wiki/Bibcode_(identifier)
- Quantum Enhancement of the Zero-Area Sagnac Interferometer Topology for Gravitational Wave Detection · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Quantum Enhancement of the Zero-Area Sagnac Interferometer Topology for Gravitational Wave Detection." Eberle, T. 2026-11-18. https://en.wikipedia.org/wiki/ArXiv_(identifier). Accessed 24 November 2026.
Chicago "Quantum Enhancement of the Zero-Area Sagnac Interferometer Topology for Gravitational Wave Detection." Eberle, T. 2026-11-18. https://en.wikipedia.org/wiki/ArXiv_(identifier).
APA Eberle, T. (2026). Quantum Enhancement of the Zero-Area Sagnac Interferometer Topology for Gravitational Wave Detection. Retrieved November 24, 2026, from https://en.wikipedia.org/wiki/ArXiv_(identifier)
- Optical wavefront measurement using a novel phase-shifting point-diffraction interferometer · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Optical wavefront measurement using a novel phase-shifting point-diffraction interferometer." Ferraro, P. 2026-11-18. http://spie.org/x8369.xml. Accessed 24 November 2026.
Chicago "Optical wavefront measurement using a novel phase-shifting point-diffraction interferometer." Ferraro, P. 2026-11-18. http://spie.org/x8369.xml.
APA Ferraro, P. (2026). Optical wavefront measurement using a novel phase-shifting point-diffraction interferometer. Retrieved November 24, 2026, from http://spie.org/x8369.xml
- Triple Michelson interferometer for a third-generation gravitational wave detector · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Triple Michelson interferometer for a third-generation gravitational wave detector." Freise, A. 2026-11-18. https://en.wikipedia.org/wiki/ArXiv_(identifier). Accessed 24 November 2026.
Chicago "Triple Michelson interferometer for a third-generation gravitational wave detector." Freise, A. 2026-11-18. https://en.wikipedia.org/wiki/ArXiv_(identifier).
APA Freise, A. (2026). Triple Michelson interferometer for a third-generation gravitational wave detector. Retrieved November 24, 2026, from https://en.wikipedia.org/wiki/ArXiv_(identifier)
- Hariharan, P. (2007). Basics of Interferometry, 2nd edition . Elsevier. p. 19. ISBN 978-0-12-373589-8 . Wikipedia revision 1365792551, retrieved 2026-11-19 · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Hariharan, P. (2007). Basics of Interferometry, 2nd edition . Elsevier. p. 19. ISBN 978-0-12-373589-8 . Wikipedia revision 1365792551, retrieved 2026-11-19." Hariharan, P. 2026-11-18. https://en.wikipedia.org/wiki/ISBN_(identifier). Accessed 24 November 2026.
Chicago "Hariharan, P. (2007). Basics of Interferometry, 2nd edition . Elsevier. p. 19. ISBN 978-0-12-373589-8 . Wikipedia revision 1365792551, retrieved 2026-11-19." Hariharan, P. 2026-11-18. https://en.wikipedia.org/wiki/ISBN_(identifier).
APA Hariharan, P. (2026). Hariharan, P. (2007). Basics of Interferometry, 2nd edition . Elsevier. p. 19. ISBN 978-0-12-373589-8 . Wikipedia revision 1365792551, retrieved 2026-11-19. Retrieved November 24, 2026, from https://en.wikipedia.org/wiki/ISBN_(identifier)
- Sensitivity analysis of the Sagnac-effect optical-fiber ring interferometer · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Sensitivity analysis of the Sagnac-effect optical-fiber ring interferometer." Lin, S. 2026-11-18. https://en.wikipedia.org/wiki/Bibcode_(identifier). Accessed 24 November 2026.
Chicago "Sensitivity analysis of the Sagnac-effect optical-fiber ring interferometer." Lin, S. 2026-11-18. https://en.wikipedia.org/wiki/Bibcode_(identifier).
APA Lin, S. (2026). Sensitivity analysis of the Sagnac-effect optical-fiber ring interferometer. Retrieved November 24, 2026, from https://en.wikipedia.org/wiki/Bibcode_(identifier)
- Binary adaptive optics: atmospheric wave-front correction with a half-wave phase shifter · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Binary adaptive optics: atmospheric wave-front correction with a half-wave phase shifter." Love, G. 2026-11-18. https://web.archive.org/web/20121107000706/http://www.dur.ac.uk/g.d.love/downloadable/p011Binary_adapt_optics.pdf. Accessed 24 November 2026.
Chicago "Binary adaptive optics: atmospheric wave-front correction with a half-wave phase shifter." Love, G. 2026-11-18. https://web.archive.org/web/20121107000706/http://www.dur.ac.uk/g.d.love/downloadable/p011Binary_adapt_optics.pdf.
APA Love, G. (2026). Binary adaptive optics: atmospheric wave-front correction with a half-wave phase shifter. Retrieved November 24, 2026, from https://web.archive.org/web/20121107000706/http://www.dur.ac.uk/g.d.love/downloadable/p011Binary_adapt_optics.pdf
- Common-Path Interferometers · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Common-Path Interferometers." a b c Mallick, S. 2026-11-18. https://en.wikipedia.org/wiki/Doi_(identifier). Accessed 24 November 2026.
Chicago "Common-Path Interferometers." a b c Mallick, S. 2026-11-18. https://en.wikipedia.org/wiki/Doi_(identifier).
APA a b c Mallick, S. (2026). Common-Path Interferometers. Retrieved November 24, 2026, from https://en.wikipedia.org/wiki/Doi_(identifier)
- High data density temperature measurement for quasi steady-state flows · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "High data density temperature measurement for quasi steady-state flows." Mercer, C. 2026-11-18. https://ntrs.nasa.gov/archive/nasa/casi.ntrs.nasa.gov/19960033183_1996063135.pdf. Accessed 24 November 2026.
Chicago "High data density temperature measurement for quasi steady-state flows." Mercer, C. 2026-11-18. https://ntrs.nasa.gov/archive/nasa/casi.ntrs.nasa.gov/19960033183_1996063135.pdf.
APA Mercer, C. (2026). High data density temperature measurement for quasi steady-state flows. Retrieved November 24, 2026, from https://ntrs.nasa.gov/archive/nasa/casi.ntrs.nasa.gov/19960033183_1996063135.pdf
- Superresolution optical system by common-path interferometry · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Superresolution optical system by common-path interferometry." Mico, V. 2026-11-18. http://www.uv.es/~gpoei/articulos/(2006)%20OEX%2014%20(12)%20Superresolution%20optical%20system%20by%20common-path%20interferometry.pdf. Accessed 24 November 2026.
Chicago "Superresolution optical system by common-path interferometry." Mico, V. 2026-11-18. http://www.uv.es/~gpoei/articulos/(2006)%20OEX%2014%20(12)%20Superresolution%20optical%20system%20by%20common-path%20interferometry.pdf.
APA Mico, V. (2026). Superresolution optical system by common-path interferometry. Retrieved November 24, 2026, from http://www.uv.es/~gpoei/articulos/(2006)%20OEX%2014%20(12)%20Superresolution%20optical%20system%20by%20common-path%20interferometry.pdf
- Instantaneous phase-shift, point-diffraction interferometer · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Instantaneous phase-shift, point-diffraction interferometer." Millerd, J. 2026-11-18. https://web.archive.org/web/20101008174420/http://www.optics.arizona.edu/jcwyant/pdf/Published_Papers/Phase_Shifting/InstantaneousPhase-shiftPoint-diffractionInterferometer.pdf. Accessed 24 November 2026.
Chicago "Instantaneous phase-shift, point-diffraction interferometer." Millerd, J. 2026-11-18. https://web.archive.org/web/20101008174420/http://www.optics.arizona.edu/jcwyant/pdf/Published_Papers/Phase_Shifting/InstantaneousPhase-shiftPoint-diffractionInterferometer.pdf.
APA Millerd, J. (2026). Instantaneous phase-shift, point-diffraction interferometer. Retrieved November 24, 2026, from https://web.archive.org/web/20101008174420/http://www.optics.arizona.edu/jcwyant/pdf/Published_Papers/Phase_Shifting/InstantaneousPhase-shiftPoint-diffractionInterferometer.pdf
- Phase measurements of a twisted nematic liquid crystal spatial light modulator with a common-path interferometer · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Phase measurements of a twisted nematic liquid crystal spatial light modulator with a common-path interferometer." Márquez, A. 2026-11-18. https://en.wikipedia.org/wiki/Bibcode_(identifier). Accessed 24 November 2026.
Chicago "Phase measurements of a twisted nematic liquid crystal spatial light modulator with a common-path interferometer." Márquez, A. 2026-11-18. https://en.wikipedia.org/wiki/Bibcode_(identifier).
APA Márquez, A. (2026). Phase measurements of a twisted nematic liquid crystal spatial light modulator with a common-path interferometer. Retrieved November 24, 2026, from https://en.wikipedia.org/wiki/Bibcode_(identifier)
- Extreme-ultraviolet phase-shifting point-diffraction interferometer: A wave-front metrology tool with subangstrom reference-wave accuracy · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Extreme-ultraviolet phase-shifting point-diffraction interferometer: A wave-front metrology tool with subangstrom reference-wave accuracy." Naulleau, P. 2026-11-18. https://en.wikipedia.org/wiki/Bibcode_(identifier). Accessed 24 November 2026.
Chicago "Extreme-ultraviolet phase-shifting point-diffraction interferometer: A wave-front metrology tool with subangstrom reference-wave accuracy." Naulleau, P. 2026-11-18. https://en.wikipedia.org/wiki/Bibcode_(identifier).
APA Naulleau, P. (2026). Extreme-ultraviolet phase-shifting point-diffraction interferometer: A wave-front metrology tool with subangstrom reference-wave accuracy. Retrieved November 24, 2026, from https://en.wikipedia.org/wiki/Bibcode_(identifier)
- Newton, Isaac (1730). Opticks: or, a Treatise of the Reflections, Refractions, Inflections and Colours of Light . Project Gutenberg. pp. 317– 406. Wikipedia revision 1365792551, retrieved 2026-11-19 · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Newton, Isaac (1730). Opticks: or, a Treatise of the Reflections, Refractions, Inflections and Colours of Light . Project Gutenberg. pp. 317– 406. Wikipedia revision 1365792551, retrieved 2026-11-19." Newton, Isaac (1730). 2026-11-18. http://www.gutenberg.org/files/33504/33504-h/33504-h.htm. Accessed 24 November 2026.
Chicago "Newton, Isaac (1730). Opticks: or, a Treatise of the Reflections, Refractions, Inflections and Colours of Light . Project Gutenberg. pp. 317– 406. Wikipedia revision 1365792551, retrieved 2026-11-19." Newton, Isaac (1730). 2026-11-18. http://www.gutenberg.org/files/33504/33504-h/33504-h.htm.
APA Newton, Isaac (1730). (2026). Newton, Isaac (1730). Opticks: or, a Treatise of the Reflections, Refractions, Inflections and Colours of Light . Project Gutenberg. pp. 317– 406. Wikipedia revision 1365792551, retrieved 2026-11-19. Retrieved November 24, 2026, from http://www.gutenberg.org/files/33504/33504-h/33504-h.htm
- The Sagnac Interferometer · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "The Sagnac Interferometer." "The Sagnac Interferometer" (PDF). 2026-11-18. http://www.optics.arizona.edu/opti471a/Sagnac/The%20Sagnac%20Interferometer.pdf. Accessed 24 November 2026.
Chicago "The Sagnac Interferometer." "The Sagnac Interferometer" (PDF). 2026-11-18. http://www.optics.arizona.edu/opti471a/Sagnac/The%20Sagnac%20Interferometer.pdf.
APA "The Sagnac Interferometer" (PDF). (2026). The Sagnac Interferometer. Retrieved November 24, 2026, from http://www.optics.arizona.edu/opti471a/Sagnac/The%20Sagnac%20Interferometer.pdf
- Twyman-Green Interferometer · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Twyman-Green Interferometer." 2026-11-18. http://www.optique-ingenieur.org/en/courses/OPI_ang_M02_C05/co/Contenu_31.html. Accessed 24 November 2026.
Chicago "Twyman-Green Interferometer." 2026-11-18. http://www.optique-ingenieur.org/en/courses/OPI_ang_M02_C05/co/Contenu_31.html.
APA encyclopegia.org. (2026). Twyman-Green Interferometer. Retrieved November 24, 2026, from http://www.optique-ingenieur.org/en/courses/OPI_ang_M02_C05/co/Contenu_31.html
- Demonstration of closed-loop adaptive optics with a point-diffraction interferometer in strong scintillation with optical vortices · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Demonstration of closed-loop adaptive optics with a point-diffraction interferometer in strong scintillation with optical vortices." Paterson, C. 2026-11-18. https://doi.org/10.1364%2FOE.15.013745. Accessed 24 November 2026.
Chicago "Demonstration of closed-loop adaptive optics with a point-diffraction interferometer in strong scintillation with optical vortices." Paterson, C. 2026-11-18. https://doi.org/10.1364%2FOE.15.013745.
APA Paterson, C. (2026). Demonstration of closed-loop adaptive optics with a point-diffraction interferometer in strong scintillation with optical vortices. Retrieved November 24, 2026, from https://doi.org/10.1364%2FOE.15.013745
- Interferometry following adaptive optics · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Interferometry following adaptive optics." Ribak, E. 2026-11-18. https://web.archive.org/web/20130225133243/http://physics.technion.ac.il/~eribak/GlasgowAOInt.pdf. Accessed 24 November 2026.
Chicago "Interferometry following adaptive optics." Ribak, E. 2026-11-18. https://web.archive.org/web/20130225133243/http://physics.technion.ac.il/~eribak/GlasgowAOInt.pdf.
APA Ribak, E. (2026). Interferometry following adaptive optics. Retrieved November 24, 2026, from https://web.archive.org/web/20130225133243/http://physics.technion.ac.il/~eribak/GlasgowAOInt.pdf
- Twyman-Green Interferometer · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Twyman-Green Interferometer." 2026-11-18. http://spie.org/x32483.xml. Accessed 24 November 2026.
Chicago "Twyman-Green Interferometer." 2026-11-18. http://spie.org/x32483.xml.
APA encyclopegia.org. (2026). Twyman-Green Interferometer. Retrieved November 24, 2026, from http://spie.org/x32483.xml
- Lateral Shear Interferometers · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Lateral Shear Interferometers." Strojnik, M. 2026-11-18. https://en.wikipedia.org/wiki/Doi_(identifier). Accessed 24 November 2026.
Chicago "Lateral Shear Interferometers." Strojnik, M. 2026-11-18. https://en.wikipedia.org/wiki/Doi_(identifier).
APA Strojnik, M. (2026). Lateral Shear Interferometers. Retrieved November 24, 2026, from https://en.wikipedia.org/wiki/Doi_(identifier)
- Sagnac Interferometer for Gravitational-Wave Detection · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Sagnac Interferometer for Gravitational-Wave Detection." Sun, K. 2026-11-18. https://nlo.stanford.edu/fejerpubs/1996/93.pdf. Accessed 24 November 2026.
Chicago "Sagnac Interferometer for Gravitational-Wave Detection." Sun, K. 2026-11-18. https://nlo.stanford.edu/fejerpubs/1996/93.pdf.
APA Sun, K. (2026). Sagnac Interferometer for Gravitational-Wave Detection. Retrieved November 24, 2026, from https://nlo.stanford.edu/fejerpubs/1996/93.pdf
- Tonomura, A. (1999). Electron Holography, 2nd ed . Springer. ISBN 3-540-64555-1 . Wikipedia revision 1365792551, retrieved 2026-11-19 · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Tonomura, A. (1999). Electron Holography, 2nd ed . Springer. ISBN 3-540-64555-1 . Wikipedia revision 1365792551, retrieved 2026-11-19." Tonomura, A. 2026-11-18. https://books.google.com/books?id=ghn_GeKbRo0C. Accessed 24 November 2026.
Chicago "Tonomura, A. (1999). Electron Holography, 2nd ed . Springer. ISBN 3-540-64555-1 . Wikipedia revision 1365792551, retrieved 2026-11-19." Tonomura, A. 2026-11-18. https://books.google.com/books?id=ghn_GeKbRo0C.
APA Tonomura, A. (2026). Tonomura, A. (1999). Electron Holography, 2nd ed . Springer. ISBN 3-540-64555-1 . Wikipedia revision 1365792551, retrieved 2026-11-19. Retrieved November 24, 2026, from https://books.google.com/books?id=ghn_GeKbRo0C
- Testing Curved Surfaces and Lenses · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Testing Curved Surfaces and Lenses." a b "Testing Curved Surfaces and Lenses" (PDF). 2026-11-18. https://web.archive.org/web/20100725064530/http://www.optics.arizona.edu/jcwyant/Short_Courses/SIRA/6-TestingCurvedSurfaces.pdf. Accessed 24 November 2026.
Chicago "Testing Curved Surfaces and Lenses." a b "Testing Curved Surfaces and Lenses" (PDF). 2026-11-18. https://web.archive.org/web/20100725064530/http://www.optics.arizona.edu/jcwyant/Short_Courses/SIRA/6-TestingCurvedSurfaces.pdf.
APA a b "Testing Curved Surfaces and Lenses" (PDF). (2026). Testing Curved Surfaces and Lenses. Retrieved November 24, 2026, from https://web.archive.org/web/20100725064530/http://www.optics.arizona.edu/jcwyant/Short_Courses/SIRA/6-TestingCurvedSurfaces.pdf
- Common-path interferometer for frequency-domain optical coherence tomography · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Common-path interferometer for frequency-domain optical coherence tomography." a b Vakhtin, A. 2026-11-18. http://swsciences.com/research/papers/Vakhtin_2003_ApplOpt_CommonPathInterferometer.pdf. Accessed 24 November 2026.
Chicago "Common-path interferometer for frequency-domain optical coherence tomography." a b Vakhtin, A. 2026-11-18. http://swsciences.com/research/papers/Vakhtin_2003_ApplOpt_CommonPathInterferometer.pdf.
APA a b Vakhtin, A. (2026). Common-path interferometer for frequency-domain optical coherence tomography. Retrieved November 24, 2026, from http://swsciences.com/research/papers/Vakhtin_2003_ApplOpt_CommonPathInterferometer.pdf
- White Light Interferometry · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "White Light Interferometry." Wyant, J. 2026-11-18. https://web.archive.org/web/20060906064907/http://www.optics.arizona.edu/jcwyant/pdf/Published_Papers/Optical_Testing/WhiteLightInterferometry.pdf. Accessed 24 November 2026.
Chicago "White Light Interferometry." Wyant, J. 2026-11-18. https://web.archive.org/web/20060906064907/http://www.optics.arizona.edu/jcwyant/pdf/Published_Papers/Optical_Testing/WhiteLightInterferometry.pdf.
APA Wyant, J. (2026). White Light Interferometry. Retrieved November 24, 2026, from https://web.archive.org/web/20060906064907/http://www.optics.arizona.edu/jcwyant/pdf/Published_Papers/Optical_Testing/WhiteLightInterferometry.pdf
- The Velocity of Light Within a Massive Enclosure · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "The Velocity of Light Within a Massive Enclosure." G. 2026-11-18. https://en.wikipedia.org/wiki/Physical_Review. Accessed 24 November 2026.
Chicago "The Velocity of Light Within a Massive Enclosure." G. 2026-11-18. https://en.wikipedia.org/wiki/Physical_Review.
APA G. (2026). The Velocity of Light Within a Massive Enclosure. Retrieved November 24, 2026, from https://en.wikipedia.org/wiki/Physical_Review
- Influence of Motion of the Medium on the Velocity of Light · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Influence of Motion of the Medium on the Velocity of Light." Michelson, A. 2026-11-18. https://zenodo.org/record/1450072. Accessed 24 November 2026.
Chicago "Influence of Motion of the Medium on the Velocity of Light." Michelson, A. 2026-11-18. https://zenodo.org/record/1450072.
APA Michelson, A. (2026). Influence of Motion of the Medium on the Velocity of Light. Retrieved November 24, 2026, from https://zenodo.org/record/1450072
- Hammar's experiment · retrieved 2026-11-18 · rev 1365792551
Cite this reference
MLA "Hammar's experiment." H. 2026-11-18. https://archive.org/details/relativitycosmol00robe. Accessed 24 November 2026.
Chicago "Hammar's experiment." H. 2026-11-18. https://archive.org/details/relativitycosmol00robe.
APA H. (2026). Hammar's experiment. Retrieved November 24, 2026, from https://archive.org/details/relativitycosmol00robe
- Common-path interferometer · retrieved 2026-10-19 · rev 1365792551
Cite this reference
MLA "Common-path interferometer." Wikipedia. 2026-10-19. https://en.wikipedia.org/w/index.php?oldid=1365792551. Accessed 24 November 2026.
Chicago "Common-path interferometer." Wikipedia. 2026-10-19. https://en.wikipedia.org/w/index.php?oldid=1365792551.
APA Wikipedia. (2026). Common-path interferometer. Retrieved November 24, 2026, from https://en.wikipedia.org/w/index.php?oldid=1365792551
Cite this article
MLA
"Common-path interferometer." encyclopegia.org, 2026, https://encyclopegia.org/wiki/common-path-interferometer. Accessed 24 November 2026.
Chicago
"Common-path interferometer." encyclopegia.org. Accessed November 24, 2026. https://encyclopegia.org/wiki/common-path-interferometer.
APA
encyclopegia.org. (2026). Common-path interferometer. Retrieved November 24, 2026, from https://encyclopegia.org/wiki/common-path-interferometer
Accessed November 24, 2026 · CC BY-SA 4.0 · citation page · JSON
Claims
| Predicate | Value | Source |
|---|---|---|
| publication date | 1913 | Wikipedia |