Control valve

A control valve is a valve used to control fluid flow by varying the size of the flow passage as directed by a signal from a controller.[src] This enables the direct control of flow rate and the consequential control of process quantities such as pressure, temperature, and liquid level.[src] In automatic control terminology, a control valve is termed a "final control element".[src]

A control valve is a valve used to control fluid flow by varying the size of the flow passage as directed by a signal from a controller.[src] This enables the direct control of flow rate and the consequential control of process quantities such as pressure, temperature, and liquid level.[src] In automatic control terminology, a control valve is termed a "final control element".[src] ==Operation== The opening or closing of automatic control valves is usually done by electrical, hydraulic or pneumatic actuators.[src] Normally with a modulating valve, which can be set to any position between fully open and fully closed, valve positioners are used to ensure the valve attains the desired degree of opening.[src] Air-actuated valves are commonly used because of their simplicity, as they only require a compressed air supply, whereas electrically operated valves require additional cabling and switch gear, and hydraulically actuated valves required high pressure supply and return lines for the hydraulic fluid.[src] The pneumatic control signals are traditionally based on a pressure range of 3–15 psi (0.2–1.0 bar), or more commonly now, an electrical signal of 4-20mA for industry, or 0–10 V for HVAC systems.[src] Electrical control now often includes a "Smart" communication signal superimposed on the 4–20 mA control current, such that the health and verification of the valve position can be signalled back to the controller.[src] The HART, Fieldbus Foundation, Profinet, and Profibus are the most common protocols.[src] An automatic control valve consists of three main parts in which each part exist in several types and designs: Valve actuator – which moves the valve's modulating element, such as ball or butterfly.[src] Valve positioner – which ensures the valve has reached the desired degree of opening.[src] This overcomes the problems of friction and wear.[src] Valve body – in which the modulating element, a plug, globe, ball or butterfly, is contained.[src] ==Control action== Taking the example of an air-operated valve, there are two control actions possible: "Air or current to open" – The flow restriction decreases with increased control signal value.[src] "Air or current to close" – The flow restriction increases with increased control signal value.[src] There can also be failure to safety modes: "Air or control signal failure to close" – On failure of compressed air to the actuator, the valve closes under spring pressure or by backup power.[src] "Air or control signal failure to open" – On failure of compressed air to actuator, the valve opens under spring pressure or by backup power.[src] The modes of failure operation are requirements of the failure to safety process control specification of the plant.[src] In the case of cooling water it may be to fail open, and the case of delivering a chemical it may be to fail closed.[src] ==Valve positioners== The fundamental function of a positioner is to deliver pressurized air to the valve actuator, such that the position of the valve stem or shaft corresponds to the set point from the control system.[src] Positioners are typically used when a valve requires throttling action.[src] A positioner requires position feedback from the valve stem or shaft and delivers pneumatic pressure to the actuator to open and close the valve.[src] The positioner must be mounted on or near the control valve assembly.[src] There are three main categories of positioners, depending on the type of control signal, the diagnostic capability, and the communication protocol: pneumatic, analog, and digital.[src] ===Pneumatic positioners=== Processing units may use pneumatic pressure signaling as the control set point to the control valves.[src] Pressure is typically modulated between 20.7 and 103 kPa (3 to 15 psig) to move the valve from 0 to 100% position.[src] In a common pneumatic positioner, the position of the valve stem or shaft is compared with the position of a bellows that receives the pneumatic control signal.[src] When the input signal increases, the bellows expands and moves a beam.[src] The beam pivots about an input axis, which moves a flapper closer to the nozzle.[src] The nozzle pressure increases, which increases the output pressure to the actuator through a pneumatic amplifier relay.[src] The increased output pressure to the actuator causes the valve stem to move.[src] Stem movement is fed back to the beam by means of a cam.[src] As the cam rotates, the beam pivots about the feedback axis to move the flapper slightly away from the nozzle.[src] The nozzle pressure decreases and reduces the output pressure to the actuator.[src] Stem movement continues, backing the flapper away from the nozzle until equilibrium is reached.[src] When the input signal decreases, the bellows contracts (aided by an internal range spring) and the beam pivots about the input axis to move the flapper away from the nozzle.[src] Nozzle decreases and the relay permits the release of diaphragm casing pressure to the atmosphere, which allows the actuator stem to move upward.[src] Through the cam, stem movement is fed back to the beam to reposition the flapper closer to the nozzle.[src] When equilibrium conditions are obtained, stem movement stops and the flapper is positioned to prevent any further decrease in actuator pressure.[src] ===Analog positioners=== The second type of positioner is an analog I/P positioner.[src] Most modern processing units use a 4 to 20 mA DC signal to modulate the control valves.[src] This introduces electronics into the positioner design and requires that the positioner convert the electronic current signal into a pneumatic pressure signal (current-to-pneumatic or I/P).[src] In a typical analog I/P positioner, the converter receives a DC input signal and provides a proportional pneumatic output signal through a nozzle/flapper arrangement.[src] The pneumatic output signal provides the input signal to the pneumatic positioner.[src] Otherwise, the design is the same as the pneumatic positioner ===Digital positioners=== While pneumatic positioners and analog I/P positioners provide basic valve position control, digital valve controllers add another dimension to positioner capabilities.[src] This type of positioner is a microprocessor-based instrument.[src] The microprocessor enables diagnostics and two-way communication to simplify setup and troubleshooting.[src] In a typical digital valve controller, the control signal is read by the microprocessor, processed by a digital algorithm, and converted into a drive current signal to the I/P converter.[src] The microprocessor performs the position control algorithm rather than a mechanical beam, cam, and flapper assembly.[src] As the control signal increases, the drive signal to the I/P converter increases, increasing the output pressure from the I/P converter.[src] This pressure is routed to a pneumatic amplifier relay and provides two output pressures to the actuator.[src] With increasing control signal, one output pressure always increases and the other output pressure decreases Double-acting actuators use both outputs, whereas single-acting actuators use only one output.[src] The changing output pressure causes the actuator stem or shaft to move.[src] Valve position is fed back to the microprocessor.[src] The stem continues to move until the correct position is attained.[src] At this point, the microprocessor stabilizes the drive signal to the I/P converter until equilibrium is obtained.[src] In addition to the function of controlling the position of the valve, a digital valve controller has two additional capabilities: diagnostics and two-way digital communication.[src] Widely used communication protocols include HART, FOUNDATION fieldbus, and PROFIBUS.[src] Advantages of placing a smart positioner on a control valve: Automatic calibration and configuration of positioner.[src] Real time diagnostics.[src] Reduced cost of loop commissioning, including installation and calibration.[src] Use of diagnostics to maintain loop performance levels.[src] Improved process control accuracy that reduces process variability.[src] ==Types of control valve== Control valves are classified by attributes and features.[src] ===Based on the pressure drop profile=== High recovery valve: These valves typically regain most of static pressure drop from the inlet to vena contracta at the outlet.[src] They are characterized by a lower recovery coefficient.[src] Examples: butterfly valve, ball valve, plug valve, gate valve Low recovery valve: These valves typically regain little of the static pressure drop from the inlet to vena contracta at the outlet.[src] They are characterized by a higher recovery coefficient.[src] Examples: globe valve, angle valve ===Based on the movement profile of the controlling element=== Sliding stem: The valve stem / plug moves in a linear, or straight line motion.[src] Examples: Globe valve, angle valve, wedge type gate valve Rotary valve: The valve disc rotates.[src] Examples: Butterfly valve, ball valve ===Based on the functionality=== Control valve: Controls flow parameters proportional to an input signal received from the central control system.[src] Examples: Globe valve, angle valve, ball valve Shut-off / On-off valve: These valves are either completely open or closed.[src] Examples: Gate valve, ball valve, globe valve, angle valve, pinch valve, diaphragm valve Check valve: Allows flow only in a single direction Steam conditioning valve: Regulates the pressure and temperature of inlet media to required parameters at outlet.[src] Examples: Turbine bypass valve, process steam letdown station Spring-loaded safety valve: Closed by the force of a spring, which retracts to open when the inlet pressure is equal to the spring force ===Based on the actuating medium=== Manual valve: Actuated by hand wheel Pneumatic valve: Actuated using a compressible medium like air, hydrocarbon, or nitrogen, with a spring diaphragm, piston cylinder or piston-spring type actuator Hydraulic valve: Actuated by a non-compressible medium such as water or oil Electric valve: Actuated by an electric motor A wide variety of valve types and control operation exist.[src] However, there are two main forms of action, the sliding stem and the rotary.[src] The most common and versatile types of control valves are sliding-stem globe, V-notch ball, butterfly and angle types.[src] Their popularity derives from rugged construction and the many options available that make them suitable for a variety of process applications.[src] Control valve bodies may be categorized as below: ===List of common types of control valve=== Sliding stem Rotary Other ==See also== ==References== ==External links== Control Valve Handbook Fluid Control Research Institute New era of valve design and engineering[src]

81 sentences · 81 cited inline · 0 references stored

References

No reference rows published for this article.

Cite this article

MLA

"Control valve." encyclopegia.org, 2026, https://encyclopegia.org/wiki/control-valve. Accessed 27 November 2026.

Chicago

"Control valve." encyclopegia.org. Accessed November 27, 2026. https://encyclopegia.org/wiki/control-valve.

APA

encyclopegia.org. (2026). Control valve. Retrieved November 27, 2026, from https://encyclopegia.org/wiki/control-valve

Accessed November 27, 2026 · CC BY-SA 4.0 · citation page · JSON

Related articles

Take Over Control

stub · references available

automatic frequency control

stub · references available

access control

stub · references available

Media Control Interface

stub · references available

Need to Control

stub · references available

butterfly valve

stub · references available

Active Body Control

stub · references available
CC BY-SA 4.0 · share-alike · https://en.wikipedia.org/w/index.php?oldid=1357926704 · 0.5 · snapshot enwiki-001357926704

Cite · JSON · Search

Related services and records

Services

  • Estate — measured countries, lanes and facts
  • Intel — live corroborated events
  • Legal — statutes, cases and citations
  • Encyclopedia — articles with inline sources
  • Space — launches, satellites and orbits
  • Search — federated search and reports
  • Pass — passport account and SSO
  • Corpora — read-only corpus origins
  • e01 — self-hosted corpora and tools
  • Careers — open roles: frontier engineers and sales partners

Text and metadata only; each target carries its own sources. Missing data is published as no-data, never estimated.