In electrical and electronic engineering, a current clamp, also known as current probe, is an electrical device with jaws which open to allow clamping around an electrical conductor.[src] This allows measurement of the current in a conductor without the need to make physical contact with it, or to disconnect it for insertion through the probe.[src] Current clamps are typically used to read the magnitude of alternating current (AC) and, with additional instrumentation, the phase and waveform can also be measured.[src] Some clamp meters can measure currents of 1000 A and more.[src] Hall effect and vane type clamps can also measure direct current (DC).[src]

In electrical and electronic engineering, a current clamp, also known as current probe, is an electrical device with jaws which open to allow clamping around an electrical conductor.[src] This allows measurement of the current in a conductor without the need to make physical contact with it, or to disconnect it for insertion through the probe.[src] Current clamps are typically used to read the magnitude of alternating current (AC) and, with additional instrumentation, the phase and waveform can also be measured.[src] Some clamp meters can measure currents of 1000 A and more.[src] Hall effect and vane type clamps can also measure direct current (DC).[src] ==Types of current clamp== ===Hall effect=== The Hall effect type is more sensitive and is able to measure both DC and AC, in some applications, up to the kilohertz range.[src] This type was initially used with oscilloscopes, and with high-end computerized digital multimeters, however, they have become commonplace for general use.[src] ===Current transformer=== A common form of AC current clamp comprises a split ring made of ferrite or soft iron.[src] A wire coil is wound round one or both halves, forming one winding of a current transformer.[src] The conductor it is clamped around forms the other winding.[src] Like any transformer this type works only with AC or pulse waveforms, with some examples extending into the megahertz range.[src] When measuring current, the subject conductor forms the primary winding and the coil forms the secondary.[src] This type may also be used in reverse, to inject current into the conductor, for example in electromagnetic compatibility susceptibility testing to induce an interference current.[src] Usually, the injection probe is specifically designed for this purpose.[src] In this mode, the coil forms the primary and the test conductor the secondary.[src] ===Iron vane=== In the iron vane type, the magnetic flux in the core directly affects a moving iron vane, allowing both AC and DC to be measured, and gives a true root mean square (RMS) value for non-sinusoidal AC waveforms.[src] Due to its physical size it is generally limited to power transmission frequencies up to around .[src] The vane is usually fixed directly to the display mechanism of an analogue (moving pointer) clamp meter.[src] The calibration of the instrument is clearly non-linear.[src] ===Rogowski coil=== Resembling a current clamp in appearance and function is the Rogowski coil current sensor.[src] This coreless transformer is used in clamp meters and power monitoring loggers.[src] It has the advantage of better linearity, having no core to saturate, it can be made flexible, and does not require any magnetic or electrical contact at the opening end.[src] The Rogowski coil gives a voltage proportional to the rate of change of current in the primary cable, so more signal processing is needed before the sensed values can be displayed.[src] ==Clamp meter== An electrical meter with integral AC current clamp is known as a clamp meter, clamp-on ammeter, tong tester, or colloquially as an amp clamp.[src] A clamp meter measures the vector sum of the currents flowing in all the conductors passing through the probe, which depends on the phase relationship of the currents.[src] Only one conductor is normally passed through the probe.[src] In particular if the clamp is closed around a two-conductor cable carrying power to equipment, the same current flows down one conductor and up the other; the meter correctly reads a net current of zero.[src] As electrical cables for equipment have both insulated conductors (and possibly an earth wire) bonded together, clamp meters are often used with what is essentially a short extension cord with the two conductors separated, so that the clamp can be placed around only one conductor of this extension.[src] A relatively recent development is a multi-conductor clamp meter with several sensor coils around the jaws of the clamp.[src] This could be clamped around standard two- or three-conductor single-phase cables to provide a readout of the current flowing through the load, with no need to separate the conductors.[src] The reading produced by a conductor carrying a very low current can be increased by winding the conductor around the clamp several times; the meter reading divided by the number of turns is the current, with some loss of accuracy due to inductive effects.[src] Clamp meters are used by electricians, sometimes with the clamp incorporated into a general purpose multimeter.[src] It is simple to measure very high currents (hundreds of amperes) with the appropriate current transformer.[src] Accurate measurement of low currents (a few milliamperes) with a current transformer clamp is more difficult.[src] The range of any given meter can be extended by passing the conductor through the jaw multiple times.[src] For example a 0–200 A meter can be turned into a 0–20 A meter by winding the conductor 10 times around the jaw's core.[src] Less-expensive clamp meters use a rectifier circuit which actually reads mean current, but is calibrated to display the RMS current corresponding to the measured mean, giving a correct RMS reading only if the current is a sine wave.[src] For other waveforms readings will be incorrect; when these simpler meters are used with non-sinusoidal loads such as the ballasts used with fluorescent lamps or high-intensity discharge lamps or most modern computer and electronic equipment, readings can be quite inaccurate.[src] Meters which respond to true RMS rather than mean current are described as "true RMS".[src] Typical hand-held Hall effect units can read currents as low as 200 mA, and units that can read down to 1 mA are available.[src] The Columbia tong test ammeter (illustrated) is an example of the iron vane type, used for measuring large AC currents up to 1000 amperes.[src] The iron jaws of the meter direct the magnetic field surrounding the conductor to an iron vane that is attached to the needle of the meter.[src] The iron vane moves in proportion to the strength of the magnetic field, and thus produces a meter indication proportional to the current.[src] This type of ammeter can measure both AC and DC currents and provides a true RMS current measurement of non-sinusoidal or distorted AC waveforms.[src] Interchangeable meter movements can be installed in the clamping assembly to provide various full-scale current values up to 1000 amperes.[src] The iron vane is in a small cylinder that is inserted in a space at the hinged end of the clamp-on jaws.[src] Several jaw sizes are available for clamping around large conductors and bus bars up to wide.[src] As the illustration shows, the scale is very non-linear and unsuitable for measuring low currents, with currents of less than half the full-scale deflection crammed into a short section of the dial.[src] ===Power meter, energy analyzer=== Clamp probes are used with some meters to measure electrical power and energy.[src] The clamp measures the current and other circuitry the voltage; the true power is the product of the instantaneous voltage and current integrated over a cycle.[src] Comprehensive meters designed to measure many parameters of electrical energy (power factor, distortion, instantaneous power as a function of time, phase relationships, etc.), use this principle.[src] A single clamp is used for single-phase measurements; with an appropriate instrument with three clamps, measurements may be made on three-phase power systems.[src] ==References==[src]

58 sentences · 58 cited inline · 0 references stored

References

No reference rows published for this article.

Cite this article

MLA

"Current clamp." encyclopegia.org, 2026, https://encyclopegia.org/wiki/current-clamp. Accessed 26 November 2026.

Chicago

"Current clamp." encyclopegia.org. Accessed November 26, 2026. https://encyclopegia.org/wiki/current-clamp.

APA

encyclopegia.org. (2026). Current clamp. Retrieved November 26, 2026, from https://encyclopegia.org/wiki/current-clamp

Accessed November 26, 2026 · CC BY-SA 4.0 · citation page · JSON

Related articles

electric current

stub · references available

Labrador Current

stub · references available

Falkland Current

stub · references available

eddy current

stub · references available

high-voltage direct current power line

stub · references available

charcoal clamp

stub · references available

pyroclastic density current

stub · references available

current asset

stub · references available
CC BY-SA 4.0 · share-alike · https://en.wikipedia.org/w/index.php?oldid=1364702010 · 0.5 · snapshot enwiki-001364702010

Cite · JSON · Search

Related services and records

Services

  • Estate — measured countries, lanes and facts
  • Intel — live corroborated events
  • Legal — statutes, cases and citations
  • Encyclopedia — articles with inline sources
  • Space — launches, satellites and orbits
  • Search — federated search and reports
  • Pass — passport account and SSO
  • Corpora — read-only corpus origins
  • e01 — self-hosted corpora and tools

Text and metadata only; each target carries its own sources. Missing data is published as no-data, never estimated.