Data-driven control system
Data-driven control systems are a broad family of control systems, in which the identification of the process model and/or the design of the controller are based entirely on experimental data collected from the plant. In many control applications, trying to write a mathematical model of the plant is considered a hard task, requiring efforts and time to the process and control engineers. This problem is overcome by data-driven methods, which fit a system model to the experimental data collected, choosing it in a specific models class. The control engineer can then exploit this model to design a proper controller for the system. However, it is still difficult to find a simple yet reliable model for a physical system, that includes only those dynamics of the system that are of interest for the control specifications. The direct data-driven methods allow to tune a controller, belonging to a given class, without the need of an identified model of the system. In this way, one can also simply weight process dynamics of interest inside the control cost function, and exclude those dynamics that are out of interest.
Data-driven control systems are a broad family of control systems, in which the identification of the process model and/or the design of the controller are based entirely on experimental data collected from the plant. In many control applications, trying to write a mathematical model of the plant is considered a hard task, requiring efforts and time to the process and control engineers. This problem is overcome by data-driven methods, which fit a system model to the experimental data collected, choosing it in a specific models class. The control engineer can then exploit this model to design a proper controller for the system. However, it is still difficult to find a simple yet reliable model for a physical system, that includes only those dynamics of the system that are of interest for the control specifications. The direct data-driven methods allow to tune a controller, belonging to a given class, without the need of an identified model of the system. In this way, one can also simply weight process dynamics of interest inside the control cost function, and exclude those dynamics that are out of interest. Model identification aims at estimating a nominal model of the system \widehat{G} = G\left(q; \widehat{\theta}_N\right) , where q is the unit-delay operator (for discrete-time transfer functions representation) and \widehat{\theta}_N is the vector of parameters of G identified on a set of N data. Then, validation consists in constructing the uncertainty set \Gamma that contains the true system G_0 at a certain probability level. Controller design aims at finding a controller C achieving closed-loop stability and meeting the required performance with \widehat{G} . Typical objectives of system identification are to have \widehat{G} as close as possible to G_0 , and to have \Gamma as small as possible. However, from an identification for control perspective, what really matters is the performance achieved by the controller, not the intrinsic quality of the model. One way to deal with uncertainty is to design a controller that has an acceptable performance with all models in \Gamma , including G_0 . This is the main idea behind robust control design procedure, that aims at building frequency domain uncertainty descriptions of the process. However, being based on worst-case assumptions rather than on the idea of averaging out the noise, this approach typically leads to conservative uncertainty sets. Rather, data-driven techniques deal with uncertainty by working on experimental data, and avoiding excessive conservativism. In the following, the main classifications of data-driven control systems are presented. Let y^d be a desired output to the reference signal r ; the error between the achieved and desired response is \tilde{y}(\rho)=y(\rho)-y^d . The control design objective can be formulated as the minimization of the objective function: J(\rho) = \frac{1}{2N}\sum_{t=1}^N E\left[\tilde{y}(t,\rho)^2\right]. Given the objective function to minimize, the quasi-Newton method can be applied, i.e. a gradient-based minimization using a gradient search of the type: \rho_{i+1} = \rho_i - \gamma_i R_i^{-1} \frac{d\widehat{J}}{d\rho}(\rho_i). The value \gamma_i is the step size, R_i is an appropriate positive definite matrix and \frac{d\widehat{J}}{d\rho} is an approximation of the gradient; the true value of the gradient is given by the following: \frac{dJ}{d\rho} (\rho) = \frac{1}{N} \sum_{t=1}^N \left[\tilde{y}(t,\rho)\frac{\delta y}{\delta \rho}(t,\rho)\right]. The value of \frac{\delta y}{\delta \rho}(t,\rho) is obtained through the following three-step methodology: Normal Experiment: Perform an experiment on the closed loop system with C(\rho) as controller and r as reference; collect N measurements of the output y(\rho) , denoted as y^{(1)} (\rho) . Gradient Experiment: Perform an experiment on the closed loop system with C(\rho) as controller and 0 as reference r ; inject the signal r-y^{(1)} (\rho) such that it is summed to the control variable output by C(\rho) , going as input into the plant. Collect the output, denoted as y^{(2)} (\rho) . Take the following as gradient approximation: \frac{\delta \widehat{y}}{\delta \rho} (\rho) = \frac{\delta C}{\delta \rho} (\rho) y^{(2)} (\rho) . A crucial factor for the convergence speed of the algorithm is the choice of R_i ; when \tilde{y} is small, a good choice is the approximation given by the Gauss–Newton direction: R_i = \frac 1 N \sum_{t=1}^N \frac{\delta \widehat{y}}{\delta \rho} (\rho_i) \frac{\delta \widehat{y}^T}{\delta \rho} (\rho_i). Suppose that G denotes an unknown LTI stable SISO plant, M a user-defined reference model and F a user-defined weighting function. An LTI fixed-order controller is indicated as K(\rho)=\beta^T \rho , where \rho \in \mathbb R ^n , and \beta is a vector of LTI basis functions. Finally, K^* is an ideal LTI controller of any structure, guaranteeing a closed-loop function M when applied to G . The goal is to minimize the following objective function: J(\rho)=\left\| F \bigg( \frac{ K^* G-K(\rho)G }{ (1+K^* G)^2 } \bigg) \right\|_2^2. J(\rho) is a convex approximation of the objective function obtained from a model reference problem, supposing that \frac{1}{ (1+K(\rho)G) } \approx \frac{1}{ (1+K^*G) } . When G is stable and minimum-phase, the approximated model reference problem is equivalent to the minimization of the norm of \varepsilon(t) in the scheme in figure. The input signal r(t) is supposed to be a persistently exciting input signal and v(t) to be generated by a stable data-generation mechanism. The two signals are thus uncorrelated in an open-loop experiment; hence, the ideal error \varepsilon(t,\rho^* ) is uncorrelated with r(t) . The control objective thus consists in finding \rho such that r(t) and \varepsilon(t,\rho^* ) are uncorrelated. The vector of instrumental variables \zeta(t) is defined as: \zeta(t)=[r_W (t+\ell_1 ),r_W (t+\ell_1-1),\ldots,r_W (t),\ldots,r_W (t-\ell_1) ]^T where \ell_1 is large enough and r_W (t)=Wr(t) , where W is an appropriate filter. The correlation function is: f_{N,\ell_1} (\rho) = \frac{1}{N} \sum_{t=1}^N \zeta(t) \varepsilon(t,\rho) and the optimization problem becomes: \widehat{\rho} = \underset{\rho \in D_k}{\operatorname{arg\,min}} J_{N,\ell_1}(\rho) = \underset{\rho \in D_k}{\operatorname{arg\,min}} f_{N,\ell_1}^T f_{N,\ell_1}. Denoting with \phi_r (\omega) the spectrum of r(t) , it can be demonstrated that, under some assumptions, if W is selected as: W(e^{-j\omega}) = \frac{F(e^{-j\omega})(1-M(e^{-j\omega}))}{\phi_r (\omega)} then, the following holds: \lim_{N,\ell_1 \to \infty, \ell_1/N \to \infty} \widehat{\rho} = \rho^*. Due to measurement noise, even if K^*=K(\rho) is stabilizing, data-estimated \widehat{K}(\rho) may not be so. Consider a stabilizing controller K_s and the closed loop transfer function M_s=\frac{K_s G}{1+K_s G} . Define: \Delta(\rho) := M_s - K(\rho) G (1-M_s) \delta(\rho) := \left\| \Delta(\rho) \right\|_\infty. Theorem The controller K(\rho) stabilizes the plant G if \Delta(\rho) is stable \exist \delta_N \in (0,1) s.t. \delta (\rho) \leq \delta_N. Condition 1. is enforced when: K(\rho) is stable K(\rho) contains an integrator (it is canceled). The model reference design with stability constraint becomes: \rho_s = \underset{\rho \in D_k}{\operatorname{arg\,min}} J(\rho) \text{s.t. } \delta(\rho) \leq \delta_N. A convex data-driven estimation of \delta(\rho) can be obtained through the discrete Fourier transform. Define the following: \begin{align} & \widehat{R}_r (\tau) = \frac{1}{N} \sum_{t=1}^N r(t-\tau) r(t) \text{ for } \tau = -\ell_2,\ldots,\ell_2 \\[4pt] & \widehat{R}_{r\varepsilon} (\tau) = \frac{1}{N} \sum_{t=1}^N r(t-\tau) \varepsilon(t,\rho) \text{ for } \tau = -\ell_2,\ldots,\ell_2. \end{align} For stable minimum phase plants, the following convex data-driven optimization problem is given: \begin{align} \widehat{\rho} & = \underset{\rho \in D_k}{\operatorname{arg\,min}} J_{N,\ell_1}(\rho) \\[3pt] & \text{s.t.} \\[3pt] & \bigg| \sum_{\tau=-\ell_2}^{\ell_2} \widehat{R}_{r\varepsilon} (\tau,\rho) e^{-j\tau\omega_k} \bigg| \leq \delta_N \bigg| \sum_{\tau=-\ell_2}^{\ell_2} \widehat{R}_r (\tau,\rho) e^{-j\tau\omega_k} \bigg| \\[4pt] \omega_k & = \frac{2 \pi k}{2\ell_2+1}, \qquad k=0,\ldots,\ell_2+1. \end{align} The virtual signals are r_v (t)=M^{-1} y(t) and e_v (t)=r_v (t) - y(t). The optimal controller is obtained from noiseless data by solving the following optimization problem: \widehat{\rho}_\infty = \underset{\rho}{\operatorname{arg\,min}} \lim_{N \to \infty} J_{vr} (\rho) where the optimization function is given as follows: J_{vr}^N (\rho) = \frac{1}{N} \sum_{t=1}^N \left(u(t)-K(\rho) e_v(t) \right)^2. ==Further reading== Ali Khaki-Sedigh, An Introduction to Data-Driven Control Systems, November 2023 Wiley-IEEE Press 384 Pages ==External links== VRFT toolbox for MATLAB
References
No reference rows published for this article.
Cite this article
MLA
"Data-driven control system." encyclopegia.org, 2026, https://encyclopegia.org/wiki/data-driven-control-system. Accessed 24 November 2026.
Chicago
"Data-driven control system." encyclopegia.org. Accessed November 24, 2026. https://encyclopegia.org/wiki/data-driven-control-system.
APA
encyclopegia.org. (2026). Data-driven control system. Retrieved November 24, 2026, from https://encyclopegia.org/wiki/data-driven-control-system
Accessed November 24, 2026 · CC BY-SA 4.0 · citation page · JSON