Decompression practice
To prevent or minimize decompression sickness, divers must properly plan, conduct, and monitor decompression. Divers follow a decompression model to allow the release of excess inert gases dissolved in their body tissues at acceptable risk, which accumulated as a result of breathing at ambient pressures greater than surface atmospheric pressure. Decompression models take into account variables such as depth and time of dive, breathing gasses, altitude, and equipment to develop appropriate procedures for safe ascent. Decompression may be continuous or staged, where the ascent is interrupted by stops at regular depth intervals, but the entire ascent is part of the decompression, and ascent rate can be critical to harmless elimination of inert gas. What is commonly known as no-decompression diving, or more accurately no-stop decompression, relies on limiting ascent rate for avoidance of excessive bubble formation. Staged decompression may include deep stops depending on the theoretical model used for calculating the ascent schedule. Omission of decompression theoretically required for a dive profile exposes the diver to significantly higher risk of symptomatic decompression sickness, and in severe cases, serious injury or death. The risk is related to the severity of exposure and the level of supersaturation of tissues in the diver.…
To prevent or minimize decompression sickness, divers must properly plan, conduct, and monitor decompression. Divers follow a decompression model to allow the release of excess inert gases dissolved in their body tissues at acceptable risk, which accumulated as a result of breathing at ambient pressures greater than surface atmospheric pressure. Decompression models take into account variables such as depth and time of dive, breathing gasses, altitude, and equipment to develop appropriate procedures for safe ascent. Decompression may be continuous or staged, where the ascent is interrupted by stops at regular depth intervals, but the entire ascent is part of the decompression, and ascent rate can be critical to harmless elimination of inert gas. What is commonly known as no-decompression diving, or more accurately no-stop decompression, relies on limiting ascent rate for avoidance of excessive bubble formation. Staged decompression may include deep stops depending on the theoretical model used for calculating the ascent schedule. Omission of decompression theoretically required for a dive profile exposes the diver to significantly higher risk of symptomatic decompression sickness, and in severe cases, serious injury or death. The risk is related to the severity of exposure and the level of supersaturation of tissues in the diver. Procedures for emergency management of omitted decompression and symptomatic decompression sickness have been published. These procedures are generally effective, but vary in effectiveness from case to case. The procedures used for decompression depend on the mode of diving, the available equipment, the site and environment, and the actual dive profile. Standardized procedures have been developed which provide an acceptable level of risk in the circumstances for which they are appropriate. Different sets of procedures are used by commercial, military, scientific and recreational divers, though there is considerable overlap where similar equipment is used, and some concepts are common to all decompression procedures. In particular, all types of surface oriented diving benefited significantly from the acceptance of personal dive computers in the 1990s, which facilitated decompression practice and allowed more complex dive profiles at acceptable levels of risk. ==Decompression== Decompression in the context of diving derives from the reduction in ambient pressure experienced by the diver during the ascent at the end of a dive or hyperbaric exposure and refers to both the reduction in pressure and the process of allowing dissolved inert gases to be eliminated from the tissues during this reduction in pressure. When a diver descends in the water column the ambient pressure rises. Breathing gas is supplied at the same pressure as the surrounding water, and some of this gas dissolves into the diver's blood and other fluids. Inert gas continues to be taken up until the gas dissolved in the diver is in a state of equilibrium with the breathing gas in the diver's lungs, (see: "Saturation diving"), or the diver moves up in the water column and reduces the ambient pressure of the breathing gas until the inert gases dissolved in the tissues are at a higher concentration than the equilibrium state, and start diffusing out again. Dissolved inert gases such as nitrogen or helium can form bubbles in the blood and tissues of the diver if the partial pressures of the dissolved gases in the diver gets too high above the ambient pressure. These bubbles and products of injury caused by the bubbles can cause damage to tissues known as decompression sickness, or "the bends". The immediate goal of controlled decompression is to avoid development of symptoms of bubble formation in the tissues of the diver, and the long-term goal is to also avoid complications due to sub-clinical decompression injury. A diver who exceeds the no-decompression limit for a decompression algorithm or table has a theoretical tissue gas loading which is considered likely to cause symptomatic bubble formation unless the ascent follows a decompression schedule, and is said to have a decompression obligation. ====Profile determined intermediate stops==== Profile-dependent intermediate stops (PDIS)s are intermediate stops at a depth above the depth at which the leading compartment for the decompression calculation switches from on gassing to off gassing and below the depth of the first obligatory decompression stop, (or the surface, on a no-stop dive). The ambient pressure at that depth is low enough to ensure that the tissues are mostly off gassing inert gas, although under a very small pressure gradient. This combination is expected to inhibit bubble growth. The leading compartment is generally not the fastest compartment except in very short dives, for which this model does not require an intermediate stop. The 8 compartment Bühlmann - based UWATEC ZH-L8 ADT MB PMG decompression model in the Scubapro Galileo dive computer processes the dive profile and suggests an intermediate 2-minute stop that is a function of the tissue nitrogen loading at that time, taking into account the accumulated nitrogen from previous dives. Within the Haldanian logic of the model, at least three compartments are off gassing at the prescribed depth - leading compartment and the 5 and 10-minute half time compartments. A PDIS is not a mandatory stop, nor is it considered a substitute for the more important shallow safety stop on a no-stop dive. Switching breathing gas mix during the ascent will influence the depth of the stop. The PDIS concept was introduced by Sergio Angelini. ====Omitted decompression procedures==== A procedure for dealing with omitted decompression stops is described in the US Navy Diving Manual. In principle the procedure allows a diver who is not yet presenting symptoms of decompression sickness, to go back down and complete the omitted decompression, with some extra time added to deal with the bubbles which are assumed to have formed during the period where the decompression ceiling was violated. Divers who become symptomatic before they can be returned to depth are treated for decompression sickness, and do not attempt the omitted decompression procedure as the risk is considered unacceptable under normal operational circumstances. If a decompression chamber is available, omitted decompression may be managed by chamber recompression to an appropriate pressure, and decompression following either a surface decompression schedule or a treatment table. If the diver develops symptoms in the chamber, treatment can be started without further delay. Sea level equivalent depth = Actual depth at altitude × Pressure at sea level ÷ Pressure at altitude Decompression stop depths are also corrected, using the ratio of surface pressures, and will produce actual stop depths which are shallower than the sea level stop depths. Stop depth at altitude = Stop depth at sea level × Pressure at altitude ÷ Pressure at sea level These values can be used with standard open circuit decompression tables, but are not applicable with constant oxygen partial pressure as provided by closed circuit rebreathers. Tables are used with the sea level equivalent depth and stops are done at the altitude stop depth. The decompression algorithms can be adjusted to compensate for altitude. This was first done by Bühlmann for deriving altitude corrected tables, and is now common on diving computers, where an altitude setting can be selected by the user, or altitude may be measured by the computer if it is programmed to take surface atmospheric pressure into account. ==Technical diving== Technical diving includes profiles that are relatively short and deep, and which are inefficient in terms of decompression time for a given bottom time. They also often lie outside the range of profiles with validated decompression schedules, and tend to use algorithms developed for other types of diving, often extrapolated to depths for which no formal testing has been done. Often modifications are made to produce shorter or safer decompression schedules, but the evidence relevant to these modifications is often difficult to locate when it exists. The widespread belief that bubble algorithms and other modifications which produce deeper stops are more efficient than the dissolved phase models is not borne out by formal experimental data, which suggest that the incidence of decompression symptoms may be higher for same duration schedules using deeper stops, due to greater saturation of slower tissues over the deeper profile. ===Gas switching=== It appears that gas switching from mixtures based on helium to nitrox during ascent does not accelerate decompression in comparison with dives using only helium diluent, but there is some evidence that the type of symptoms displayed is skewed towards neurological in heliox only dives. There is also some evidence that heliox to nitrox switches are implicated in inner ear decompression sickness which occurs during decompression. Suggested strategies to minimise risk of vestibular DCS are to ensure adequate initial decompression, and to make the switch to nitrox at a relatively shallow depth (less than 30 m), while using the highest acceptably safe oxygen fraction during decompression at the switch. Deep technical diving usually involves the use of several breathing gas mixtures during the course of the dive. There will be a mixture known as the bottom gas, which is optimised for limiting inert gas narcosis and oxygen toxicity during the deep sector of the dive. This is generally the mixture which is needed in the largest amount for open circuit diving, as the consumption rate will be greatest at maximum depth. The oxygen fraction of the bottom gas suitable for a dive deeper than about will not have sufficient oxygen to reliably support consciousness at the surface, so a travel gas must be carried to start the dive and get down to the depth at which the bottom gas is appropriate. There is generally a large overlap of depths where either gas can be used, and the choice of the point at which the switch will be made depends on considerations of cumulative toxicity, narcosis and gas consumption logistics specific to the planned dive profile. During ascent, there will be one or more depths at which the diver may switch to a gas with a higher oxygen fraction, which will also accelerate decompression. If the travel gas is suitable, it can be used for decompression too, and it is a common choice for the first decompression gas. Additional oxygen rich decompression gas mixtures may be selected to optimise decompression times at shallower depths. These will usually be selected as soon as the partial pressure of oxygen is acceptable, to minimise required decompression, and there may be more than one such mixture depending on the planned decompression schedule. The shallowest stops may be done breathing pure oxygen. During prolonged decompression at high oxygen partial pressures, it may be advisable to take what is known as air breaks, where the diver switches back to a low oxygen fraction gas (usually bottom gas or travel gas) for a short period (usually about 5 minutes) to reduce the risk of developing oxygen toxicity symptoms, before continuing with the high oxygen fraction accelerated decompression. These multiple gas switches require the diver to select and use the correct demand valve and cylinder for each switch, and if using a dive computer, to select the correct gas from the gas menu at each switch. An error of selection could compromise the decompression, or result in a loss of consciousness due to oxygen toxicity or hypoxia. The diver is faced with a problem of optimising for gas volume carried, number of different gases carried, depths at which switches can be made, bottom time, decompression time, gases available for emergency use, and at which depths they become available, both for themself and other members of the team, while using available cylinders and remaining able to manage the cylinders during the dive. This problem can be simplified if staging the cylinders is possible. This is the practice of leaving a cylinder at a point on the return route where it can be picked up and used, possibly depositing the previously used cylinder, which will be retrieved later, or having a support diver supply additional gas. These strategies rely on the diver being reliably able to get to the staged gas supply. The staged cylinders are usually clipped off to the distance line or shotline to make them easier to find. ====Management of multiple cylinders==== When multiple cylinders containing different gas mixtures are carried, the diver must ensure that the correct gas is breathed for the depth and stage of the dive. Breathing a gas with inappropriate oxygen partial pressure risks loss of consciousness and compromising the decompression plan. When switching, the diver must be certain of the composition of the new gas, and make the correct adjustments to decompression computer settings. Various systems have been used to identify the gas, the demand valve, and the source cylinder. One in general use and found by experience to be reliable, is to clearly label the cylinder with the maximum operating depth of the contents, as this is the most critical information, carry the demand valve on the cylinder, and leave the cylinder valve closed when the cylinder is not in use. This allows the diver to visually identify the mix as suitable for the current depth, select the demand valve at the cylinder, and confirm that it is the demand valve from that cylinder by opening the cylinder valve to release the gas. After the mix is confirmed and in use, the diver will switch over the computer to select the current gas from the menu, so that decompression computation can remain correct. It is not unusual for deep technical dives to require three or four gas mixtures in addition to bottom gas, which is generally carried in back-mounted cylinders. There is a convention to carry the most oxygen-rich additional gases on the right side, and the lower oxygen fraction gases on the left side. This practice reduces the chances of confusion at depth and in poor visibility, and saves a little time when looking for the correct gas. Several models of technical dive computer can be set before the dive with the gas mixtures to be used, and will indicate when one of them is more suitable for the current depth than the gas in use. Some models of gas-integrated dive computer will detect which cylinder is in use by a change in content pressure transmitted via the pressure transmitter mounted on the regulator on that cylinder, and will automatically switch to the gas setting associated with that specific regulator's pressure transmitter. ====Emergency decompression from saturation==== Very little is known with confidence about how best to decompress from saturation in an emergency. A DMAC consensus document has been issued with tentative advice on possible procedures based on a balance of perceived risk. These procedures are not supported by experience or experimental work as there is very little of either, and constitute an educated guess at best. The risk of symptomatic decompression sickness is expected to increase as the rate of decompression increases, with earlier pain only symptoms, and more serious symptoms developing later or at higher decompression rates. A relatively high partial pressure of oxygen is considered likely to increase the rate of safe outgassing, but at a higher risk of oxygen toxicity. ===Oxygen prebreathing=== pre-breathes prior to an EVA Oxygen prebreathing is a procedure used to reduce the risk of decompression sickness before a hypobaric exposure to a pressure where the risk is significant. It is used in military aviation before flights to high altitudes, and in spaceflight before extravehicular activity in space suits with a relatively low working internal pressure. When space suits with an operating pressure less than about 55 kPa absolute are used from craft that are pressurized to normal atmospheric pressure (such as the Space Shuttle), this requires astronauts to "pre-breathe" pure oxygen for a period before donning their suits and depressurizing in the air lock. This procedure purges the body of dissolved nitrogen, so as to avoid decompression sickness due to rapid depressurization from a nitrogen-containing atmosphere. In the US space shuttle, cabin pressure was reduced from normal atmospheric to 70kPa, equivalent to an altitude of about 3000m, for 24 hours before EVA, and after donning the suit, a pre-breathing period of 45 minutes on pure oxygen before decompressing to the EMU working pressure of 30kPa. In the International Space Station, there is no cabin pressure reduction; instead a 4 hour pre-breathe of oxygen at normal cabin pressure is used to desaturate nitrogen to an acceptable level. US studies show that a rapid decompression from 101 kPa to 55 kPa has an acceptable risk, and Russian studies show that direct decompression from 101 kPa to 40 kPa after 30 minutes of oxygen pre-breathing, roughly the time required for pre-EVA suit checks, is acceptable. ==Risk management== Risk management for decompression sickness involves following decompression schedules of known and acceptable risk, providing mitigation in the event of a hit (diving term indicating symptomatic decompression sickness), and reducing risk to an acceptable level by following recommended practice and avoiding deprecated practice to the extent considered appropriate by the responsible person and the divers involved. The risk of decompression sickness for the algorithms in common use is not always accurately known. Human testing under controlled conditions with the end condition of symptomatic decompression sickness is no longer frequently carried out for ethical reasons. A considerable amount of self-experimentation is done by technical divers, but conditions are generally not optimally recorded, and there are usually several unknowns, and no control group. Several practices are recommended to reduce risk based on theoretical arguments, but the value of many of these practices in reducing risk is uncertain, particularly in combinations. The vast majority of professional and recreational diving is done under low risk conditions and without recognised symptoms, but in spite of this there are occasionally unexplained incidences of decompression sickness. The earlier tendency to blame the diver for not properly following the procedures has been shown to not only be counterproductive, but sometimes factually wrong, and it is now generally recognised that there is statistically a small but real risk of symptomatic decompression sickness for even highly conservative profiles. This acceptance by the diving community that sometimes one is simply unlucky encourages more divers to report borderline cases, and the statistics gathered may provide more complete and precise indications of risk as they are analysed. ===Conservatism=== Decompression conservatism refers to the application of factors to a basic decompression algorithm or set of tables that are expected to decrease the risk of developing symptomatic decompression sickness when following a given dive profile. This practice has a long history, originating with the practice of decompressing according to the tables for a dive deeper than the actual depth, longer than the actual bottom time, or both. These practices were empirically developed by divers and supervisors to account for factors that they considered increased risk, such as hard work during the dive, or cold water. With the development of computer programs to calculate decompression schedules for specified dive profiles, came the possibility of adjusting the allowed percentage of the maximum supersaturation (M-values). This feature became available in dive computers as an optional personal setting in addition to any conservatism added by the manufacturer, and the range of base conservatism set by manufacturers is large. Conservatism also varies between decompression algorithms due to the different assumptions and mathematical models used. In this case the conservatism is considered relative, as in most cases the validity of the model remains open to question, and has been adjusted empirically to produce a statistically acceptable risk by the designers. Where the depth, pressure and gas mixture exposure on a dive is outside of the experimentally tested range, the risk is unknown, and conservatism of adjustments to the allowable theoretical tissue gas load is relative to an unknown risk. The application of user conservatism for dive computers varies considerably. The general tendency in dive computers intended for the recreational market is to provide one or two preset conservatism settings which have the effect of reducing allowed no-decompression limit in a way which is not transparent to the user. Technical divers, who are required to have a deeper understanding of the theoretical basis of decompression algorithms, often want to be able to set conservatism as an informed choice, and technical computers often provide this option. For the popular Bühlmann algorithm, it is usually in the form of gradient factors. In some cases the computer may provide a readout of the current computed percentage of the M-value in real time, as an aid to managing a situation where the diver must balance decompression risk against other risks to make the ascent. The converse of conservative decompression is termed . This may be used to minimise in-water time for exceptional exposure dives by divers willing to accept the unknown personal risk associated with the practice. A choice of reduced conservatism may also be used by more risk averse divers in a situation where the apparent decompression risk is perceived to be less dire than other possible consequences, such as drowning due to running out of breathing gas, development of debilitating hypothermia, seriously deteriorating water and weather conditions, a medical emergency, or imminent shark attack. Some dive computers allow for these types of contingencies by allowing the diver to adjust gradient factors during the dive, or optionally displaying the limiting tissue surfacing gradient factor for immediate surfacing without further decompression (Surfacing GF on Shearwater computers). This facility can allow the diver to weigh up the relative risks as much as reasonably practicable and balance decompression risk against the other risks. ===Recommended practices=== Practices for which there is some evidence or theoretical model suggesting that they may reduce risk of decompression sickness: Extended decompression: Providing that the depth is shallow enough that effectively no further inert gas tissue loading will occur, more decompression time will reduce the risk of decompression sickness, but with diminishing returns. In practice this can be facilitated by using two decompression computers. One is set at the least conservative setting acceptable to the diver, and is used to indicate minimum acceptable decompression and time to surface. The other is set at a conservatism which the diver considers adequate and low risk. Decompression will normally be done following the conservative setting, but if circumstances suggest getting out of the water sooner, the less conservative computer will show when the risk is at least acceptably low. Rehydration: Excessive hydration before a dive can increase the risk of immersion pulmonary oedema, but dehydration can develop during a dive due to blood shift to the core from immersion and peripheral vasoconstriction from chilling, and the natural tendency of the kidneys to eliminate what seems to be an excess. There is also a continuous water loss to breathing gas, particularly on open circuit, as the gas supplied on scuba is usually very dry. Rehydration after a dive is associated with a lower risk of decompression sickness and is helpful if symptoms develop. Mild exercise during decompression: Sufficient exercise to stimulate the circulation and maintain body temperature is thought to accelerate inert gas washout, therefore reducing the risk of decompression sickness for a given decompression schedule. Core temperature recovery Surface oxygen breathing: The use of oxygen or nitrox as a post dive breathing mixture is recommended in cases where incomplete decompression or short periods of omitted decompression have occurred, or at any time when there is doubt that decompression was sufficient. Low exertion during the ingassing stage of the dive: This reduces circulation during ingassing, so it will take longer for perfusion limited tissues to reach any specific inert gas loading. Consequently, the tissue loading at the end of the dive will be lower than if the diver worked hard. This is obviously not always possible, and may be logistically undesirable when there is a job to be done. Decompression algorithms assume and are tested at a high level of exertion, so the indicated decompression should be acceptably safe even when exertion is fairly intense. Less exertion will reduce the risk by an unknown amount. Maintaining physical fitness: Exercise to maintain physical fitness and exercise in the 24 hours previous to a dive may reduce risk of bubble formation during decompression. ===Deprecated practices=== Practices considered to either increase the risk of developing decompression sickness after diving, or for which there is theoretical risk, but insufficient data: Hot tubs, jacuzzis, showers or saunas after diving: Exposing the diver to a hot external environment immediately after diving will alter decompression stress. The net result may be good or bad depending on the inert gas load and the heat stress. Reheating a chilled or hypothermic diver can restore impaired circulation to the extremities. If the inert gas load is low, this may improve the rate of gas elimination, but larger inert gas loads might be pushed to the point of bubble formation or growth due to temperature effects on solubility. Which of these effects will predominate is unpredictable and may even vary in the same diver in a given instance. The warming of tissues precedes the increase in blood flow, so bubbles may become problematic before circulation can remove the gas. This risk is not amenable to numerical analysis and there are many variables. The risk is likely to reduce with the passage of time, lower gas loading, and higher initial temperatures of the extremities. Flying or ascent to altitude soon after diving: This is known to increase risk as it is in effect further decompression. There are specific recommendations to manage risk in such cases. In most cases they are equivalent to a long decompression stop on air at sea level ambient pressure before ascending to a higher altitude, to ensure that the controlling tissues are sufficiently desaturated. Several rules of thumb have been recommended over the years. These include waiting until one reaches a specific repetitive group, and simple surface intervals based on the recent diving history. Heavy exercise following diving: The risk is thought to be associated with an increased pulmonary shunt that allows venous blood and bubbles to bypass the lungs, allowing bubbles into the arterial system. Heavy exercise in the 4 hours following a recreational or technical dive may increase risk of bubble formation or shunts. Consumption of alcohol before and after diving: Alcohol can increase dehydration and heat loss, both considered risk factors for decompression sickness. Use of some drugs: Breathhold diving after scuba or surface supplied diving: Bubble formation is more likely after significant decompression stress, and the risk increases with residual inert gas load, so deeper freediving and more intense exercise will have a greater associated risk. Diving after long flights: Long distance flying tends to leave the traveller tired and somewhat dehydrated, which is thought to be a factor predisposing to DCS due to less efficient inert gas elimination. Statistics are insufficient to show cause and effect but about a third of decompression sickness incidents reported annually from the Caribbean occur after the first day's dives. Diving during pregnancy: The change in risk of decompression sickness during pregnancy is unknown, and it is considered unethical to conduct experiments with an endpoint of symptomatic decompression sickness in pregnant women, so data is unlikely to accumulate sufficiently to allow the risk to be assessed realistically. The precautionary principle suggests that the risk should be avoided by not diving when pregnant. A history of diving during early stages of pregnancy is not considered likely to have adverse effects on the fetus, but the recommendations are to avoid it. Diving while medically unfit to dive: Saw-tooth dive profile: In a saw tooth profile the diver ascends and descends a number of times during the dive. Each ascent and descent increases the risk of decompression sickness if there are any bubbles already in the diver's tissues. The increase in risk depends on the ascent rate, magnitude and duration of the upwards excursion, the saturation levels of the tissues, and to some extent the time spent after returning to depth. Accurate assessment of the increase of risk is not currently (2016) possible. Dive profiles with multiple complete or incomplete ascents are known to produce higher post-dive venous bubble counts, measured by Doppler ultrasound, than similar profiles at relatively constant depth. ===Real time contingency management using a decompression computer=== A consequence of using a decompression computer to monitor gas loading during a dive is that it becomes possible to adapt the dive plan during the dive, but it remains necessary to ensure that there is sufficient gas remaining to make the return to the surface with all necessary decompression while providing emergency gas for a buddy. Tools for adapting the dive plan for contingencies during a dive are available on some technical diving computers. The primary change in dive planning was that the ascent profile became controlled by the computer for the actual decompression obligation of the dive up to and including the parts of the ascent already done. Dive computers have become more reliable and more affordable, so it is fairly common for tech divers to have a backup computer. This reduces the risk of a computer failure during the dive necessitating an ascent controlled by depth gauge, timer and dive tables, and all the extra functionality and flexibility remains available to the diver. One of the options available is to set up the backup computer with different display settings and user options, but when these can be selected at any time during the dive, there is no great advantage provided the diver is sufficiently familiar with the device. ====Deteriorating sea state==== A deteriorating sea state can make depth control difficult. The most efficient elimination of inert gas occurs at a pressure gradient close to that which could cause bubble formation, at or just below the decompression ceiling. If it is difficult to reliably remain at the optimum depth, it is generally safer to descend to a depth where depth that reduces the risk of violating the ceiling, provided that depth still allows decompression at a rate which is compatible with the available gas supply. In such circumstances attempting to maintain neutral buoyancy can be heavy task loading and the use of a buoyed line is much more reliable. Enough negative buoyancy to avoid a possible runaway ascent, balanced by a surface buoy of sufficient buoyancy to prevent inadvertent descent is desirable. A fairly high volume, low waterplane area buoy will minimise transient vertical forces on the diver, and arm movement can compensate for some of the vertical buoy movement. ===Decompression emergencies=== A decompression emergency occurs when the diver cannot safely complete obligatory decompression while ascending, or when an uncontrolled or excessively rapid ascent occurs, or symptoms of decompression sickness develop during the decompression. An uncompleted or omitted decompression could be due to insufficient breathing gas, excessive buoyancy, inability to maintain depth at stops, or a more pressing need to surface due to another emergency. The urgency and severity of the emergency depends on the level of decompression stress and the risk of symptomatic decompression illness developing. Symptomatic decompression illness may develop during or after ascent. The urgency depends on the amount of compromised decompression, and on symptoms and when they occur. Some decompression emergencies can be mitigated on site, for example, by returning to depth with extra gas and following an omitted decompression procedure, or doing surface decompression if a chamber is available on site. In some circumstances in-water recompression may be appropriate, and in others prophylactic surface breathing of oxygen may be sufficient. Advice from a diving medicine specialist is always appropriate. ===Emergency decompression=== An emergency decompression occurs when the diver is prevented from ascending according to the planned schedule, and does not have the necessary information or equipment to do a controlled decompression ascent to an acceptable schedule, or the circumstances do not allow it, or during an emergency ascent, when the diver judges and accepts that the circumstances indicate that the overall risk to life and health are reduced by performing a decompression that is sub-optimal.
References
No reference rows published for this article.
Cite this article
MLA
"Decompression practice." encyclopegia.org, 2026, https://encyclopegia.org/wiki/decompression-practice. Accessed 24 November 2026.
Chicago
"Decompression practice." encyclopegia.org. Accessed November 24, 2026. https://encyclopegia.org/wiki/decompression-practice.
APA
encyclopegia.org. (2026). Decompression practice. Retrieved November 24, 2026, from https://encyclopegia.org/wiki/decompression-practice
Accessed November 24, 2026 · CC BY-SA 4.0 · citation page · JSON