Design load
In general, the term design load can refer to two distinct concepts: # the maximum amount a system is designed to handle, or # the maximum amount the system is capable of producing.[src] These interpretations represent fundamentally different aspects of system performance.[src] The design load is either the same as or a multiple of the rated load, which represents the system's declared performance capacity, see structural design load section below.[src] Structures and pressure vessels have design loads of the first type.[src] Electric motors, compressors and heaters have design loads of the second type.[src] Cranes have design loads of both the first and second type because they have to lift a defined load and do that at a specified speed.[src]
In general, the term design load can refer to two distinct concepts: the maximum amount a system is designed to handle, or the maximum amount the system is capable of producing.[src] These interpretations represent fundamentally different aspects of system performance.[src] The design load is either the same as or a multiple of the rated load, which represents the system's declared performance capacity, see structural design load section below.[src] Structures and pressure vessels have design loads of the first type.[src] Electric motors, compressors and heaters have design loads of the second type.[src] Cranes have design loads of both the first and second type because they have to lift a defined load and do that at a specified speed.[src] A crane's rated load is its Safe Working Load (SWL) and the design load (DL) is, (p 90) DL=\psi SWL The dynamic lift factor for offshore cranes in the range 10 kN \psi = 1.3 .(p 84) Thus for a crane with a SWL of 2000 kN (~200 tonne) its design load is not less than, DL = 1.3\times2000 = 2600 kN The minimum breaking load (MBL) for the combined capacity of reeves of a steel wire hoisting rope required on this size of crane is, (p 68) MBL = 2.3 DL=2.3\times 2600 = 5980 kN Thus the MBL is 2.3 times of the DL and ~3 times that of the SWL for this example.[src] Similar ratios are obtained for other parts of the crane's structure.[src] This factor of safety has been shown to be required when a failure could be catastrophic, such as a crane dropping its load or collapsing entirely.[src] The dynamic lift factor increases as the SWL of a crane decreases and its exact value is dependent on the hoisting speed of the crane and other factors.[src] These calculations are more complex and beyond the scope of this article.[src] ==See also== Limit states design Factor of safety Specified load ==References==[src]
18 sentences · 18 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"Design load." encyclopegia.org, 2025, https://encyclopegia.org/wiki/design-load. Accessed 26 November 2026.
Chicago
"Design load." encyclopegia.org. Accessed November 26, 2026. https://encyclopegia.org/wiki/design-load.
APA
encyclopegia.org. (2025). Design load. Retrieved November 26, 2026, from https://encyclopegia.org/wiki/design-load
Accessed November 26, 2026 · CC BY-SA 4.0 · citation page · JSON