encyclopegia.org

Dew point

The dew point is the temperature that air, of a constant absolute humidity and pressure, must be cooled to in order for the relative humidity to rise to 100%.[src] This temperature is a thermodynamic property that depends on the pressure and water content of the air.[src] When the air at a temperature above the dew point is cooled, its moisture capacity is reduced, and when the temperature passes below the dew point water vapor will condense, or precipitate, to form liquid water.[src] When this occurs through the air's contact with a colder surface, the precipitate on that surface is dew.[src] The dew point is affected by the air's absolute humidity.[src] The more moisture the air contains, the higher its dew point.[src] When the temperature is below the freezing point of water, the dew point is called the frost point, as frost is formed via deposition rather than condensation.[src] In liquids, the analog to the dew point is the cloud point.[src]

The dew point is the temperature that air, of a constant absolute humidity and pressure, must be cooled to in order for the relative humidity to rise to 100%.[src] This temperature is a thermodynamic property that depends on the pressure and water content of the air.[src] When the air at a temperature above the dew point is cooled, its moisture capacity is reduced, and when the temperature passes below the dew point water vapor will condense, or precipitate, to form liquid water.[src] When this occurs through the air's contact with a colder surface, the precipitate on that surface is dew.[src] The dew point is affected by the air's absolute humidity.[src] The more moisture the air contains, the higher its dew point.[src] When the temperature is below the freezing point of water, the dew point is called the frost point, as frost is formed via deposition rather than condensation.[src] In liquids, the analog to the dew point is the cloud point.[src] \begin{align} \gamma(T,\mathrm{RH}) & = \ln\left( \frac{\mathrm{RH}}{\ 100\ } \right) + \frac{b\ T}{\ c\ +\ T\ }\ ;\\[8pt] T_\mathsf{d} & = \frac{\ c\ \gamma(T,\mathrm{RH})\ }{\ b\ -\ \gamma(T,\mathrm{RH})\ }\ ; \end{align} where = 17.625 and = 243.04 °C.[src] The values of and were selected by minimizing the maximum deviation over the range −40 °C to +50 °C.[src] The more complete formulation and origin of this approximation involves the interrelated saturated water vapor pressure (in units of millibars, also called hectopascals) at , s ( ), and the actual vapor pressure (also in units of millibars), a ( ), which can be either found with or approximated with the barometric pressure (in millibars), mbar , and "wet-bulb" temperature, wet is (unless declared otherwise, all temperatures are expressed in degrees Celsius): \begin{align} P_\mathrm{s}(T)& = \frac{\ 100\ }{\ \mathrm{RH}\ }\ P_\mathrm{a}(T) = a\ e^{\frac{b\ T}{\ c\ +\ T\ }}\ ; \\[8pt] P_\mathrm{a}(T) & = \frac\mathrm{RH}{100}\ P_\mathrm{s}(T) = a\ e^{\gamma(T,\mathrm{RH})} \\[8pt] &\approx P_\mathrm{s}(T_\mathrm{w}) - \mathrm{BP}_\mathsf{mbar}\ 0.00066\ \left( 1 + 0.00115\ T_\mathsf{wet} \right) \left( T - T_\mathsf{wet} \right)\ ;\\[8pt] T_\mathsf{d} & = \frac{\ c\ \ln\frac{\ P_\mathrm{a}(T)\ }{ a }\ }{\ b - \ln\frac{\ P_\mathrm{a}(T)\ }{ a } }\ ; \end{align} For greater accuracy, water's saturation pressure can be modeled using the Arden Buck equation instead of the Magnus equation.[src] This is known as the Bögel modification and introduces a fourth constant, d .[src] These enhanced approximations are marked below with a subscript \mathrm m : \begin{align} P_\mathrm{s,m}(T) & = a\ e^{\left( b\ -\ \frac{\ T\ }{ d } \right) \left(\frac{ T }{\ c\ +\ T\ }\right)}\ ;\\[8pt] \gamma_\mathrm{m}(T,\mathrm{RH}) &= \ln\left(\frac{\ \mathrm{RH}\ }{\ 100\ }\ e^{\left( b\ -\ \frac{\ T\ }{ d } \right) \left(\frac{ T }{\ c\ +\ T\ }\right)} \right)\ ; \\[8pt] T_\mathsf{d} & = \frac{\ c\ \ln\frac{\ P_\mathrm{a}(T)\ }{ a }\ }{\ b - \ln\frac{\ P_\mathrm{a}(T)\ }{ a }\ } = \frac{\ c\ \ln\left( \frac{\ \mathrm{RH}\ }{\ 100\ }\frac{\ P_\mathrm{s,m}(T)\ }{ a }\right)\ }{\ b\ -\ \ln\left(\frac{\ \mathrm{RH}\ }{\ 100\ } \frac{\ P_\mathrm{s,m}(T)\ }{ a }\right)\ } = \frac{\ c\ \gamma_{\mathrm m}(T,\mathrm{RH})\ }{\ b\ -\ \gamma_{\mathrm m}(T,\mathrm{RH})\ }; \end{align} where = 6.1121 mbar ,   = 18.678 ,   = 257.14 °C ,   = 234.5 °C.[src] There are several different constant sets in use.[src] The ones used in NOAA's presentation are taken from a 1980 paper by David Bolton in the Monthly Weather Review: = 6.112 mbar, = 17.67, = 243.5 °C.[src] These valuations provide a maximum error of 0.1%, for and Also noteworthy is the Sonntag1990, = 6.112 mbar ,   = 17.62 ,   = 243.12 °C ;     for (error ±0.35 °C).[src] Another common set of values originates from the 1974 Psychrometry and Psychrometric Charts.[src] = 6.105 mbar ,   = 17.27 ,   = 237.7 °C ;     for (error ±0.4 °C).[src] Also, in the Journal of Applied Meteorology and Climatology, Arden Buck provides several different valuation sets, with different maximum errors for different temperature ranges.[src] Two particular sets provide a range of −40 °C to +50 °C between the two, with even lower maximum error within the indicated range than all the sets above: = 6.1121 mbar ,   = 17.368 ,   = 238.88 °C ;    for (error ≤ 0.05%).[src] = 6.1121 mbar ,   = 17.966 ,   = 247.15 °C ;     for (error ≤ 0.06%).[src] \begin{align} T_\mathrm{d} &\approx T - \frac{\ 100-\mathrm{RH}\ }{ 5 }\ ; \\[5pt] \mathrm{RH} &\approx 100 - 5\ ( T - T_\mathrm{d} )\ ; \end{align} This can be expressed as a simple rule of thumb: For every 1 °C difference in the dew point and dry bulb temperatures, the relative humidity decreases by 5%, starting with RH = 100% when the dew point equals the dry bulb temperature.[src] The derivation of this approach, a discussion of its accuracy, comparisons to other approximations, and more information on the history and applications of the dew point, can be found in an article published in the Bulletin of the American Meteorological Society.[src] For temperatures in degrees Fahrenheit, these approximations convert to \begin{align} T_\mathrm{d,^\circ F} &\approx T_\mathrm{{}^\circ F} - \tfrac{\ 9\ }{25}\ \left(100 - \mathrm{RH} \right)\ ;\\[5pt] \mathrm{RH} &\approx 100 - \tfrac{25}{\ 9\ }\ \left(T_\mathrm{{}^\circ F} - T_\mathrm{d,^\circ F} \right)\ ; \end{align} For example, a relative humidity of 100% means dew point is the same as air temp.[src] For 90% , dew point is 3 °F lower than air temperature.[src] For every 10 percent lower, dew point drops 3 °F.[src]

34 sentences · 34 cited inline · 0 references stored

References

No reference rows published for this article.

Cite this article

MLA

"Dew point." encyclopegia.org, 2026, https://encyclopegia.org/wiki/dew-point. Accessed 28 November 2026.

Chicago

"Dew point." encyclopegia.org. Accessed November 28, 2026. https://encyclopegia.org/wiki/dew-point.

APA

encyclopegia.org. (2026). Dew point. Retrieved November 28, 2026, from https://encyclopegia.org/wiki/dew-point

Accessed November 28, 2026 · CC BY-SA 4.0 · citation page · JSON

Related articles

Breezy Point

stub · references available

Center Point

stub · references available

central point

stub · references available

Deception Point

stub · references available

Point Arguello

stub · references available

Zero moment point

stub · references available

Boiling Point

stub · references available
CC BY-SA 4.0 · share-alike · https://en.wikipedia.org/w/index.php?oldid=1374206378 · 0.5 · snapshot enwiki-001374206378

Cite · JSON · Search

Related services and records

Services

  • Estate — measured countries, lanes and facts
  • Intel — live corroborated events
  • Legal — statutes, cases and citations
  • Encyclopedia — articles with inline sources
  • Space — launches, satellites and orbits
  • Search — federated search and reports
  • Pass — passport account and SSO
  • Corpora — read-only corpus origins
  • e01 — self-hosted corpora and tools
  • Careers — open roles: frontier engineers and sales partners

Text and metadata only; each target carries its own sources. Missing data is published as no-data, never estimated.