encyclopegia.org

Dive computer

A dive computer, personal decompression computer or decompression meter is a device used by an underwater diver to measure the elapsed time and depth during a dive and use this data to calculate and display an ascent profile which, according to the programmed decompression algorithm, will give a low risk of decompression sickness. A secondary function is to record the dive profile, warn the diver when certain events occur, and provide useful information about the environment. Dive computers are a development from decompression tables, the diver's watch and depth gauge, with greater accuracy and the ability to monitor dive profile data in real time. Most dive computers use real-time ambient pressure input to a decompression algorithm to indicate the remaining time to the no-stop limit, and after that has passed, the minimum decompression required to surface with an acceptable risk of decompression sickness. Several algorithms have been used, and various personal conservatism factors may be available. Some dive computers allow for gas switching during the dive, and some monitor the pressure remaining in the scuba cylinders. Audible alarms may be available to warn the diver when exceeding the no-stop limit, the maximum operating depth for the breathing gas mixture, the recommended ascent rate, decompression ceiling, or other limit beyond which risk increases significantly.…

A dive computer, personal decompression computer or decompression meter is a device used by an underwater diver to measure the elapsed time and depth during a dive and use this data to calculate and display an ascent profile which, according to the programmed decompression algorithm, will give a low risk of decompression sickness. A secondary function is to record the dive profile, warn the diver when certain events occur, and provide useful information about the environment. Dive computers are a development from decompression tables, the diver's watch and depth gauge, with greater accuracy and the ability to monitor dive profile data in real time. Most dive computers use real-time ambient pressure input to a decompression algorithm to indicate the remaining time to the no-stop limit, and after that has passed, the minimum decompression required to surface with an acceptable risk of decompression sickness. Several algorithms have been used, and various personal conservatism factors may be available. Some dive computers allow for gas switching during the dive, and some monitor the pressure remaining in the scuba cylinders. Audible alarms may be available to warn the diver when exceeding the no-stop limit, the maximum operating depth for the breathing gas mixture, the recommended ascent rate, decompression ceiling, or other limit beyond which risk increases significantly. The display provides data to allow the diver to avoid obligatory decompression stops, or to decompress relatively safely, and includes depth and duration of the dive. This must be displayed clearly, legibly, and unambiguously at all light levels. Several additional functions and displays may be available for interest and convenience, such as water temperature and compass direction, and it may be possible to download the data from the dives to a personal computer via cable or wireless connection. Data recorded by a dive computer may be of great value to the investigators in a diving accident, and may allow the cause of an accident to be discovered. Profile information may also be useful to help decide a suitable treatment for an injured diver, so the computer should accompany the injured diver to the treatment facility. Dive computers may be wrist-mounted or fitted to a console with the submersible pressure gauge. A dive computer is perceived by recreational scuba divers and service providers to be one of the most important items of safety equipment. It is one of the most expensive pieces of diving equipment owned by most divers. Use by professional scuba divers is also common, but use by surface-supplied divers is less widespread, as the diver's depth is monitored at the surface by pneumofathometer and decompression is controlled by the diving supervisor. Some freedivers use another type of dive computer to record their dive profiles and give them useful information which can make their dives safer and more efficient, and some computers can provide both functions, but require the user to select which function is required. ====Choice of algorithm==== The algorithms available are of two basic types: Dissolved gas models and bubble models. Neither type is able to provide a reliably safe profile in their basic form, and must be adjusted empirically to fit the data. The bubble models are likely to be closer to physiological reality, and may be more accurate outside of the range of reliably known empirical data, but are computationally complex. The dissolved gas models are computationally much simpler, and may require more data fitting processing, but even then remain significantly faster to run. A relatively simple method of controlling data fitting is by systematic adjustment of M-values, which can be done by varying gradient factors, both by preprogrammed (firmware) and user input options. There is no conclusive evidence that any currently used algorithm is significantly better than all of the others, and by selective setting of the constants, most of them can be made to produce very similar ascent and decompression profiles for a given ingassing profile. When used in the recreational diving range of no-stop exposures on factory settings, it is likely that they are all acceptably safe, though some will clearly be more conservative than others. The question of whether the diver gains anything of value from the higher conservatism is an open question, when the rate of symptomatic decompression sicknesss is very low and the external risk factors are not yet amenable to computational analysis. Some manufacturers use their unverified and undisclosed modified algorithms as selling points, usually without making any specific claims about their effectiveness, and the user is in no position to make an educated choice due to the vagueness of the claims. Some others use algorithms well-defined in the literature, allowing the user who has sufficient understanding of the specific decompression model to make a relatively informed decision. Some of these also allow user modification of settings which modify algorithm conservatism following well defined methods such as gradient factors, further facilitating educated choice. ===Closed circuit rebreather monitoring and control=== Most dive computers calculate decompression for open circuit scuba where the proportions of the breathing gases are constant for each mix: these are "constant fraction" dive computers. Other dive computers are designed to model the gases in closed circuit scuba (diving rebreathers), which maintain constant partial pressures of gases by varying the proportions of gases in the mixture: these are " " dive computers. They may be switched over to constant fraction mode if the diver bails out to open circuit. There are also dive computers which monitor oxygen partial pressure in real time in combination with a user nominated diluent mixture to provide a real-time updated mix analysis which is then used in the decompression algorithm to provide decompression information, and optionally, control of the CCR gas mixture. ===Freediving computers=== A freediving computer, or general purpose dive computer in freediving mode, will record breath hold dive details automatically while the diver is underwater, and the length of the surface interval between dives. It records each dive, so there is a record of the number of dives. This is useful to ensure adequate surface interval to clear carbon dioxide buildup. Surface interval times are also useful to monitor to avoid taravana, the freediving decompression sickness. A dive computer is also the most effective way to notify the diver of the depth at which free-fall should start by a free-fall alarm. Monitoring descent and ascent speed, and verifying maximum depth are also useful when training for efficiency. Two types of freediving computer are available, the ones that are dedicated to freediving, and those that are also scuba decompression computers, with a freediving mode. A stopwatch is useful for timing static apnea, rechargeable batteries are an option in some models, and GPS can be useful for spearfishers who wish to mark a place and return to it later. A few models offer a heart rate monitor. ===User settings=== User settings are options that can be manually selected by the diver to provide information that the computer cannot select automatically. Not all computers have them and not all settings are available on those computers which have user options. Dive mode options may be available which can be selected depending on whether the dive is to be a freedive, open circuit scuba on single or multiple gases, closed circuit scuba, open circuit bailout, gauge mode, Avelo mode. If air integration and real-time oxygen partial pressure monitoring are provided, some of these setting may be automated. Conservatism options are a common user setting option. They may be input in various ways, some requiring understanding of the algorithm functionality, and others relatively arbitrary, and with details of the function often not disclosed to the user. The value of the more arbitrary settings in not clear and it is not practicable to make a realistic estimate of their value to the user. A more accessible user option is to provide gradient factor setting as user input. These adjust the basic M-values set for the tissue compartments in the firmware by a linear factor depending on the depth. GF low is the adjustment that affects the depth where the ascent slows down and the first stop is made. A small value for GF low induces deeper stops, which can occur when some tissues are still ingassing. A large value for GF low induces a shallower first stop, at the cost of higher decompression stress in the first part of the ascent. GF high setting affects the time spent decompressing at the shallow stop and the surfacing supersaturation allowed as a percentage fraction of the M-value set for surfacing in the basic algorithm. In some cases the manufacturer may state that their conservatism factor is equivalent to a specific gradient factor, which tells the diver what its effect will be to the same extent as letting them input the same gradient factors. but other conservatism settings are entirely obscure. Some computers allow the user to choose between 6 and 3m for the depth of the last obligatory decompression stop. This can make it easier to maintain a consistent depth in large swells, but with most gas mixtures, decompression will be slower. The default depth is commonly 3m. With computers that indicate current ceiling, the ceiling will not be affected by the setting, and will rise above the actual depth in the usual way. Some Suunto computers indicate a maximum ceiling of 3m, but some Shearwaters will raise the ceiling in steps of 1m until decompression is clear. There may be a user option to select whether to add a safety stop, and if so, how long it should be and at what depth range. A safety stop is by definition not an obligatory stop, so there should be no penalty for disregarding it, though doing it may give an outgassing credit for the time and depth spent, particularly if the gas has a high partial pressure of oxygen. There is nothing stopping the diver from just doing additional shallow stop time and allowing the algorithm to compute the effects for any computer, though there is no guarantee that all computers will give credit for the extra time. ===Display options=== Some computers require the user to switch between screens to view additional information, others provide default critical dive information on several screen views which van be selected during a dive, and allow user options of useful but non-essential information to be displayed on the main screen image, while still making the other screen views accessible during dives if they are likely to be useful. ===Housed smartphones=== Smartphones in underwater housings running a decompression monitoring app may be able to take photos or video as well, provided the housing is suitable. ===Avelo mode=== An optional mode for assessing real time buoyancy status for a diver using the Avelo diving system buoyancy compensation is available on a small number of Shearwater (Tern TX, Teric, Peregrine TX, or Perdix 2) and Scubapro (G2C) dive computers via firmware downloads. As of April 2025 this feature was available on Shearwater Teric wrist computers and Scubapro console computers. Real time cylinder pressure input is required, but may be via a high pressure hose (G2C) or a wireless pressure sensor (Teric). The software estimates the magnitude of positive or negative buoyancy based on the volume of ballast water added to the hydrocyinder during the dive after a neutral buoyancy state has been achieved and confirmed by the diver. Displayed information is intended to advise the diver on when to adjust the ballast so that lung volume will be sufficient for fine buoyancy control. Other user input allows wetsuit compression to be factored in. ==== Software failures and reliability issues==== There have been several instances where dive computers have been recalled due to significant safety issues in the software or factory calibration. Earlier dive computers had to have software upgrades at the factory or an approved agent. This has changed and as of 2024, it is common to be able to update firmware over the internet, via bluetooth or a cable connection. A series of Uwatec Aladin Air X NitrOx dive computers made in 1995 was recalled in 2003 due to faulty software which miscalculated desaturation time, leading to at least seven cases of DCS attributed to their use. This is not the only recall for faulty software or calibration, Suunto D6 and D9s were recalled in 2006, Oceanic Versa Pro 2A in 2006, and Dacor Darwin computers in 2005, but no injuries were reported, and the units were recalled relatively soon after the problems were reported. The Uwatec Aladin Air X Nitrox recall occurred during a class action suit and after several related lawsuits against the company and several alleged cover-ups, starting as early as 1996. The case was settled on the eve of trial. ==Management of difficult conditions== In water conditions when it is difficult to maintain a consistently accurate depth, such as for shallow stops in large swells, some computers will allow the diver to decompress at a deeper than optimum depth where the risk of violating the decompression ceiling is reduced, but this will require linger decompression and more breathing gas. If the computer can indicate a decompression ceiling and floor, the diver can remain between them and know that effective and reasonably safe decompression is happening, though it may be inefficient. By decompressing at a depth where it is practicable to remain below the ceiling in the largest waves, safety is enhanced, and by keeping as far above the floor as allows by this strategy, efficiency is enhanced. ==Ethical questions== Some questions have been raised in the diving community regarding the ethics of certain practices by dive computer manufacturers. In the continued absence of normative standards for the design and testing of dive computers, these have remained open, and the choice must be made by the user based on the information made available by the manufacturer, which may not be much. Is it ethical for the computer manufacturer to not divulge the details of the decompression model used in a dive computer? How does this affect the ability of the diver to make an informed acceptance of risk? What are the criteria for effectiveness and risk acceptability? What is an acceptable level of risk? It is generally recognised that with the current technology and understanding of decompression physiology, a zero risk algorithm is not reasonably practicable. Different sectors of the diving community accept different levels of decompression risk, and within the recreational sector, different divers accept different levels of risk. What would be an acceptable validation protocol? Should dive computers be validated on human subjects using Doppler monitoring? If so, what types of profile should be used, and how would meaningful rejection criteria be chosen? Should validation be done by an independent agency? Should the manufacturer be obliged to publish reliability data? Is it acceptable to lock out decompression monitoring functionality during a dive in the event of a profile violation, leaving the diver without any indication of a reasonable safe ascent profile at a time when it is most needed? ====Smartphone housings==== Waterproof housings are marketed which use a smartphone, depth and temperature sensors and a decompression app to provide dive computer capabilities. Depth ratings vary, but 80msw is claimed for some. Bluetooth wireless communications have been used for communication between the smartphone and external sensors. Specifications may not mention any validation tests or compliance with standards relevant to diving equipment. A variety of features are offered based on the smartphone platform. Android and iOS operating systems are supported. ====Future development==== Lang and Angelini (2009) call for development of decompression models which more closely emulate the personal physiology of the individual diver, to provide a closer match between the predicted decompression obligation and the real decompression obligation. Hardware developments are expected in three categories. Improvements associated with developments in consumer electronics, additional monitoring built into the algorithm, and developments from decompression physiology research. The market for dive computers is very small in comparison with mobile phones, so it is expected that developments will trickle down. High resolution color displays are already becoming common in high end dive computers, and can provide a wider range of more user-friendly interface options, including labels and massages in a language of choice, colour coding choices appropriate for colour blindness, Optional font size and positioning of data on the screen, graphic display of data where appropriate, such as dive profile, and uploadable site maps. GPS is already available, but only works at the surface. EPIRB technology may be useful to some divers, but is currently expensive, and requires a lot of power for transmission. Heart rate monitoring is technically available, but of questionable practical value with current decompression models. Oxygen saturation and skin temperature are feasible but also not currently useful. Doppler bubble detection is not yet practical for diver wear, and of debatable value for decompression stress prediction and analysis underwater, as most bubbles develop at the surface after the dive. ===Performance of dive computers exposed to profiles with known human subject results.=== Studies (2004) at the University of Southern California's Catalina hyperbaric chamber ran dive computers against a group of dive profiles that have been tested with human subjects, or have a large number of operational dives on record. The dive computers were immersed in water inside the chamber and the profiles were run. Remaining no-decompression times, or required total decompression times, were recorded from each computer 1 min prior to departure from each depth in the profile. The results for a 40 msw "low risk" multi-level no-decompression dive from the PADI/DSAT RDP test series provided a range of 26 min of no-decompression time remaining to 15 min of required decompression time for the computers tested. The computers which indicated required decompression may be regarded as conservative: following the decompression profile of a conservative algorithm or setting will expose the diver to a reduced risk of decompression, but the magnitude of the reduction is unknown. Conversely the more aggressive indications of the computers showing a considerable amount of remaining no-decompression time will expose the diver to a greater risk than the fairly conservative PADI/DSAT schedule, of unknown magnitude. ===Form factor=== There are four commonly used form factors: Wristwach housings are compact, light, and may be used as daily use wristwatches. Freediving computers are usually in this format, but it is also popular for scuba. Cylindrical housings (puck) fit into diving instrument consoles and have optional wrist mounts except where they are air-integrated with a high pressure hose. The shape and size were determined by the common sizes of analog mechanical diving instruments (depth gauges and pressure gauges) which commonly used console mounts. Most are slightly larger than the nominal face diameter. Rectangular housings (brick) are intended for wrist mounting, using a larger screen size for easier-to-read displays or more information on the screen. They often have a curved back surface to conform more closely with the surface of the forearm for stability, and two straps for security. There are also asymmetrically styled housings with similar characteristics and features. This may be the most popular format for technical diving. There is no standard size or shape. Smartphone housings are sized to accept a reasonable range of phone models and are therefore necessarily larger. The display area is inherently large, and display quality depends on the smartphone used. They may be wrist mounted or carried in the hand with a safety lanyard, particularly if they are also used as cameras. ==Rebreather control and monitor hardware== The functional requirements of an electronically controlled closed circuit rebreather are very similar to the functions and capacity of technical diving decompression computers for rebreather diving, and some rebreather manufacturers use dive computer hardware repackaged by dive computer manufacturers as rebreather control and monitoring units. The software may be modified to provide the display of multiple oxygen cell readings, warnings, alarms and voting logic, and the dive computer hardware may be hard-wired to the rebreather control hardware. ===Communications protocols=== The communications system used by Shearwater Research for connectivity between dive computers and rebreathers is DiveCAN, which has a physical connectivity standard and a communication protocol based on the CAN bus industry standard. ==Storage, transport and maintenance== Most dive computers mainly require adequate washing in fresh water and storage in a cool place out of direct sunlight. Longer soaking in fresh water will usually remove salt deposits that may have crystallised in crevices and in the weave of woven fabric straps, but may use more battery power if shallow immersion activates the computer. Activation depth may vary. They should be protected from impact and contact with chemicals which may damage the casing or seals, and from impact and abrasion to the faceplate. If contaminated with oils or grease, this should be removed by scrubbing with a soft brush using a mild detergent. When transported by air, some computers may be switched to airplane mode. Most dive computers are not user serviceable beyond washing, and in some cases, battery replacement. ==Training and certification== The approach to training in the use of a dive computer has changed over time. Originally a dive computer was considered special equipment, and the user was responsible for ensuring that they knew how to use it correctly. The AAUS recommendations from the Dive Computer Workshop of 1989 stipulated passing a written exam before scientific divers should be allowed to use personal dive computers in the field. As they became more common, and the usual way of monitoring the dive, minimal instruction on the use of the computer became integrated into dive training as part of the training for a given certification. This is complicated by the probability of more than one model being used by the learners on a given course, except where the school supplied the computers. Since late 2009, it has been an option for PADI Open Water Diver courses, to do a dive computer section in place of learning to use the dive tables. A booklet is supplied on how to use and select a dive computer. SDI was an early adopter of use of dive computers in training from entry level, and offers the course named SDI Computer Diver intended for divers certified through agencies which used traditional dive tables for planning during their training, and have not been formally trained in the use of dive computers. In 2024 Scuba Schools International (SSI) announced a training program called "Computer Diver" which covers the basic functionality, setup and operation of dive computers. The training is considered appropriate for ages 10 and up, to a maximum depth of 30 m, and is expected to take 3 to 6 hours. Similarly, PADI schools offer a course called "Computer Diving Specialist", which has a prerequisite certification of PADI Open Water Diver, the minimum level certification for autonomous recreational diving. The course comprises up to three classroom sessions and an optional open water dive for a beginner with a minimum experience of four open water dives limited to 18 metres to become a specialist by PADI standards. There is a wide variation in detail of operation for each manufacturer, and in many cases between the models available from each manufacturer, so only the basic information and principles are portable between models, and significant relearning is required to be able to use a new computer safely. This situation could be improved by an internationally accepted standard for user interfaces for critical functions. The information required to safely operate most dive computers is normally extracted from the owner's manual by the user, and in many cases from videos freely available on the internet. In most such situations there is no competence assessment, and the user finds out by trial and error, while diving, what they have failed to understand or remember. ==See also== ==Further reading== ==External links==

References

No reference rows published for this article.

Cite this article

MLA

"Dive computer." encyclopegia.org, 2026, https://encyclopegia.org/wiki/dive-computer. Accessed 24 November 2026.

Chicago

"Dive computer." encyclopegia.org. Accessed November 24, 2026. https://encyclopegia.org/wiki/dive-computer.

APA

encyclopegia.org. (2026). Dive computer. Retrieved November 24, 2026, from https://encyclopegia.org/wiki/dive-computer

Accessed November 24, 2026 · CC BY-SA 4.0 · citation page · JSON

Related articles

Benicio del Toro

enwiki · references available

Düsseldorf Airport

enwiki · references available

The Groundlings

enwiki · references available

Arabian horse

enwiki · references available

Ron Santo

enwiki · references available

Christian Democratic Party (Norway)

enwiki · references available

Long thoracic nerve

enwiki · references available

Rijeka

enwiki · references available

Adventures of Sonic the Hedgehog

enwiki · references available

A. P. Herbert

enwiki · references available

Mel Fisher

enwiki · references available

Natural language generation

enwiki · references available
CC BY-SA 4.0 · share-alike · https://en.wikipedia.org/w/index.php?oldid=1374183189 · 0.5 · snapshot enwiki-001374183189

Cite · JSON · Search

Related services and records

Services

  • Estate — measured countries, lanes and facts
  • Intel — live corroborated events
  • Legal — statutes, cases and citations
  • Encyclopedia — articles with inline sources
  • Space — launches, satellites and orbits
  • Search — federated search and reports
  • Pass — passport account and SSO
  • Corpora — read-only corpus origins
  • e01 — self-hosted corpora and tools

Text and metadata only; each target carries its own sources. Missing data is published as no-data, never estimated.