In a water boiler, draft is the difference between atmospheric pressure and the pressure existing in the furnace or flue gas passage.[src] Draft can also be referred to as the difference in pressure in the combustion chamber area which results in the motion of the flue gases and the air flow.[src]

In a water boiler, draft is the difference between atmospheric pressure and the pressure existing in the furnace or flue gas passage.[src] Draft can also be referred to as the difference in pressure in the combustion chamber area which results in the motion of the flue gases and the air flow.[src] ==Types of draft== Drafts are produced by the rising combustion gases in the stack, flue, or by mechanical means.[src] For example, a boiler can be put into four categories: natural, induced, balanced, and forced.[src] Natural draft: When air or flue gases flow due to the difference in density of the hot flue gases and cooler ambient gases.[src] The difference in density creates a pressure differential that moves the hotter flue gases into the cooler surroundings.[src] Forced draft: When air or flue gases are maintained above atmospheric pressure.[src] Normally it is done with the help of a forced draft fan.[src] Induced draft: When air or flue gases flow under the effect of a gradually decreasing pressure below atmospheric pressure.[src] In this case, the system is said to operate under induced draft.[src] The stacks (or chimneys) provide sufficient natural draft to meet the low draft loss needs.[src] In order to meet higher pressure differentials, the stacks must simultaneously operate with draft fans.[src] Balanced draft: When the static pressure is equal to the atmospheric pressure, the system is referred to as balanced draft.[src] Draft is said to be zero in this system.[src] ==Importance/significance== For the proper and the optimized heat transfer from the flue gases to the boiler tubes draft holds a relatively high amount of significance.[src] The combustion rate of the flue gases and the amount of heat transfer to the boiler are both dependent on the movement and motion of the flue gases.[src] A boiler equipped with a combustion chamber which has a strong current of air (draft) through the fuel bed will increase the rate of combustion (which is the efficient utilization of fuel with minimum waste of unused fuel).[src] The stronger movement will also increase the heat transfer rate from the flue gases to the boiler (which improves efficiency and circulation).[src] ==Drafting in steam locomotives== Since the stack of a locomotive is too short to provide natural draft, during normal running forced draft is achieved by directing the exhaust steam from the cylinders through a cone ("blast pipe") upwards and into a skirt at the bottom of the stack.[src] When the locomotive is stationary or in a restricted space "live" steam from the boiler is directed through an annular ring surrounding the blast pipe to produce the same effect.[src] ==See also== Cooling tower system Stack effect Controlling draught ==References==[src]

23 sentences · 23 cited inline · 0 references stored

References

No reference rows published for this article.

Cite this article

MLA

"Draft (boiler)." encyclopegia.org, 2025, https://encyclopegia.org/wiki/draft-boiler. Accessed 25 November 2026.

Chicago

"Draft (boiler)." encyclopegia.org. Accessed November 25, 2026. https://encyclopegia.org/wiki/draft-boiler.

APA

encyclopegia.org. (2025). Draft (boiler). Retrieved November 25, 2026, from https://encyclopegia.org/wiki/draft-boiler

Accessed November 25, 2026 · CC BY-SA 4.0 · citation page · JSON

CC BY-SA 4.0 · share-alike · https://en.wikipedia.org/w/index.php?oldid=1324592290 · 0.5 · snapshot enwiki-001324592290

Cite · JSON · Search

Related services and records

Services

  • Estate — measured countries, lanes and facts
  • Intel — live corroborated events
  • Legal — statutes, cases and citations
  • Encyclopedia — articles with inline sources
  • Space — launches, satellites and orbits
  • Search — federated search and reports
  • Pass — passport account and SSO
  • Corpora — read-only corpus origins
  • e01 — self-hosted corpora and tools

Text and metadata only; each target carries its own sources. Missing data is published as no-data, never estimated.