Electrical termination
terminator In electronics, electrical termination is the practice of ending a transmission line with a device that matches the characteristic impedance of the line.[src] Signal reflections occur where there is an impedance mismatch.[src] Termination prevents signals from reflecting off the end of the transmission line.[src] Reflections at the ends of unterminated transmission lines cause distortion, which can produce ambiguous digital signal levels and misoperation of digital systems.[src] Reflections in analog signal systems cause such effects as video ghosting, or power loss in radio transmitter transmission lines.[src]
terminator In electronics, electrical termination is the practice of ending a transmission line with a device that matches the characteristic impedance of the line.[src] Signal reflections occur where there is an impedance mismatch.[src] Termination prevents signals from reflecting off the end of the transmission line.[src] Reflections at the ends of unterminated transmission lines cause distortion, which can produce ambiguous digital signal levels and misoperation of digital systems.[src] Reflections in analog signal systems cause such effects as video ghosting, or power loss in radio transmitter transmission lines.[src] ==Transmission lines== Signal termination often requires the installation of a terminator at the beginning and end of a wire or cable to prevent an RF signal from being reflected back from each end, causing interference, or power loss.[src] The terminator is usually placed at the end of a transmission line or daisy chain bus (such as in SCSI), and is designed to match the AC impedance of the cable and hence minimize signal reflections, and power losses.[src] Less commonly, a terminator is also placed at the driving end of the wire or cable, if not already part of the signal-generating equipment.[src] Radio frequency currents tend to reflect from discontinuities in the cable, such as connectors and joints, and travel back down the cable toward the source, causing interference as primary reflections.[src] Secondary reflections can also occur at the cable starts, allowing interference to persist as repeated echoes of old data.[src] These reflections also act as bottlenecks, preventing the signal power from reaching the destination.[src] Transmission line cables require impedance matching to carry electromagnetic signals with minimal reflections and power losses.[src] The distinguishing feature of most transmission line cables is that they have uniform cross-sectional dimensions along their length, giving them a uniform electrical characteristic impedance.[src] Signal terminators are designed to specifically match the characteristic impedances at both cable ends.[src] For many systems, the terminator is a resistor, with a value chosen to match the characteristic impedance of the transmission line and chosen to have acceptably low parasitic inductance and capacitance at the frequencies relevant to the system.[src] Examples include 75-ohm resistors often used to terminate 75-ohm video transmission coaxial cables.[src] Types of transmission line cables include balanced line such as ladder line, and twisted pairs (Cat-6 Ethernet, Parallel SCSI, ADSL, Landline Phone, XLR audio, USB, Firewire, Serial); and unbalanced lines such as coaxial cable (Radio antenna, CATV, 10BASE5 Ethernet).[src] ===Passive=== Passive terminators often consist of a single resistor; however, significantly reactive loads may require other passive components such as inductors, capacitors, or transformers.[src] ===Active=== Active terminators consist of a voltage regulator that keeps the voltage used for the terminating resistor(s) at a constant level.[src] ====Forced perfect termination==== Forced perfect termination (FPT) can be used on single ended buses where diodes remove over and undershoot conditions.[src] The signal is locked between two actively regulated voltage levels, which results in superior performance over a standard active terminator.[src] ===SCSI=== All parallel SCSI units use terminators.[src] SCSI is primarily used for storage and backup.[src] An active terminator is a type of single-ended SCSI terminator with a built-in voltage regulator to compensate for variations in terminator power.[src] ===Controller Area Network=== Controller area network, commonly known as CAN Bus, uses terminators consisting of a 120 ohm resistor.[src] ===Dummy load=== Dummy loads are commonly used in HF to EHF circuits.[src] ===Ethernet coaxial 50 ohm=== 10BASE2 networks absolutely must have proper termination with a 50 ohm BNC terminator.[src] If the bus network is not properly terminated, too much power will be reflected, causing all of the computers on the bus to lose network connectivity.[src] ===Antenna network 75 ohm=== A terminating resistor for a television coaxial cable is often in the form of a cap, threaded to screw onto an F connector.[src] Antenna cables are sometimes used for internet connections; however, RG-6 should not be used for 10BASE2 (which should use RG-58) as the impedance mismatch can cause phasing problems with the baseband signal.[src] ===Unibus=== terminator-and-bootstrap card from a PDP-11/34 The Digital Equipment Corporation minicomputer Unibus systems used terminator cards with 178 Ω pull-up resistors on the multi-drop address and data lines and 383 Ω on the single-drop signal lines.[src] ===MIL-STD-1553=== Terminating resistor values of 78.7 ohms 2 watt 1% are used on the MIL-STD-1553 bus.[src] At the two ends of the bus, resistors connect between the positive (high) and negative (low) signal wires either in internally terminated bus couplers or external connectorized terminators.[src] The MIL-STD-1553B bus must be terminated at both ends to minimize the effects of signal reflections that can cause waveform distortion and disruption or intermittent communications failures.[src] Optionally, a high-impedance terminator (1000 to 3000 ohms) may be used in vehicle applications to simulate a future load from an unspecified device.[src] Connectorized terminators are available with or without safety chains.[src] ==References==[src]
42 sentences · 42 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"Electrical termination." encyclopegia.org, 2026, https://encyclopegia.org/wiki/electrical-termination. Accessed 27 November 2026.
Chicago
"Electrical termination." encyclopegia.org. Accessed November 27, 2026. https://encyclopegia.org/wiki/electrical-termination.
APA
encyclopegia.org. (2026). Electrical termination. Retrieved November 27, 2026, from https://encyclopegia.org/wiki/electrical-termination
Accessed November 27, 2026 · CC BY-SA 4.0 · citation page · JSON