encyclopegia.org

Electromagnet

An electromagnet is a type of magnet in which the magnetic field is produced by an electric current.[src] Electromagnets usually consist of copper wire wound into a coil.[src] A current through the wire creates a magnetic field which is concentrated along the center of the coil.[src] The magnetic field disappears when the current is turned off.[src] The wire turns are often wound around a magnetic core made from a ferromagnetic or ferrimagnetic material such as iron; the magnetic core concentrates the magnetic flux and makes a more powerful magnet.[src] The main advantage of an electromagnet over a permanent magnet is that the magnetic field can be quickly changed by controlling the amount of electric current in the winding.[src] However, unlike a permanent magnet, which needs no power, an electromagnet requires a continuous supply of current to maintain the magnetic field.[src] Electromagnets are widely used as components of other electrical devices, such as motors, generators, electromechanical solenoids, relays, loudspeakers, hard disks, MRI machines, scientific instruments, and magnetic separation equipment.[src] Electromagnets are also employed in industry for picking up and moving heavy iron objects such as scrap iron and steel.[src]

An electromagnet is a type of magnet in which the magnetic field is produced by an electric current.[src] Electromagnets usually consist of copper wire wound into a coil.[src] A current through the wire creates a magnetic field which is concentrated along the center of the coil.[src] The magnetic field disappears when the current is turned off.[src] The wire turns are often wound around a magnetic core made from a ferromagnetic or ferrimagnetic material such as iron; the magnetic core concentrates the magnetic flux and makes a more powerful magnet.[src] The main advantage of an electromagnet over a permanent magnet is that the magnetic field can be quickly changed by controlling the amount of electric current in the winding.[src] However, unlike a permanent magnet, which needs no power, an electromagnet requires a continuous supply of current to maintain the magnetic field.[src] Electromagnets are widely used as components of other electrical devices, such as motors, generators, electromechanical solenoids, relays, loudspeakers, hard disks, MRI machines, scientific instruments, and magnetic separation equipment.[src] Electromagnets are also employed in industry for picking up and moving heavy iron objects such as scrap iron and steel.[src] ==Simple solenoid== (coil of wire).[src] This drawing shows a cross-section through the center of the coil.[src] The crosses are wires in which current is moving into the page; the dots are wires in which current is moving up out of the page.[src] A common tractive electromagnet is a uniformly wound solenoid and plunger.[src] The solenoid is a coil of wire, and the plunger is made of a material such as soft iron.[src] Applying a current to the solenoid applies a force to the plunger and may make it move.[src] The plunger stops moving when the forces upon it are balanced.[src] For example, the forces are balanced when the plunger is centered in the solenoid.[src] The maximum uniform pull happens when one end of the plunger is at the middle of the solenoid.[src] An approximation for the force is where is a proportionality constant, is the cross-sectional area of the plunger, is the number of turns in the solenoid, is the current through the solenoid wire, and is the length of the solenoid.[src] For long, slender, solenoids (in units using inches, pounds force, and amperes), the value of is around 0.009 to 0.010 psi (maximum pull pounds per square inch of plunger cross-sectional area).[src] For example, a 12-inch-long coil ( ) with a long plunger with a cross section of one inch square ( ) and 11,200 ampere-turns ( ) had a maximum pull of 8.75 pounds (corresponding to ).[src] The maximum pull is increased when a magnetic stop is inserted into the solenoid.[src] The stop becomes a magnet that will attract the plunger; it adds little to the solenoid pull when the plunger is far away but dramatically increases the pull when the plunger is close.[src] An approximation for the pull is P = A N I \left[\frac{N I}{(\ell_\mathrm{a})^2 (C_1)^2} + \frac C \ell\right] = \frac{A N^2 I^2}{(\ell_\mathrm{a})^2 (C_1)^2} + \frac{C A N I}{\ell} Here is the distance between the end of the stop and the end of the plunger.[src] The additional constant for units of inches, pounds, and amperes with slender solenoids is about 2660 .[src] The first term inside the bracket represents the attraction between the stop and the plunger; the second term represents the same force as the solenoid without a stop ( ).[src] Some improvements can be made on this basic design.[src] The ends of the stop and plunger are often conical.[src] For example, the plunger may have a pointed end that fits into a matching recess in the stop.[src] The shape makes the solenoid's pull more uniform as a function of separation.[src] Another improvement is to add a magnetic return path around the outside of the solenoid (an "iron-clad solenoid").[src] The magnetic return path, just as the stop, has little impact until the air gap is small.[src] ===Ampere's law=== The magnetic field of electromagnets in the general case is given by Ampere's law: \int \mathbf{J}\cdot d\mathbf{A} = \oint \mathbf{H}\cdot d\boldsymbol{\ell} which says that the integral of the magnetizing field \mathbf{H} around any closed loop is equal to the sum of the current flowing through the loop.[src] A related equation is the Biot–Savart law, which gives the magnetic field due to each small segment of current.[src] \frac{F}{A} = \frac {(B_\text{sat})^2}{2 \mu_0} \approx 1000\ \mathrm{kPa} = 10^6 \mathrm{N/m^2} = 145\ \mathrm for the core's saturation limit, B_{sat} .[src] In more intuitive units, it is useful to remember that at 1 T the magnetic pressure is approximately .[src] Given a core geometry, the magnetic field needed for a given force can be calculated from ( ); if the result is much more than 1.6 T, a larger core must be used.[src] However, computing the magnetic field and force exerted by ferromagnetic materials in general is difficult for two reasons.[src] First, the strength of the field varies from point to point in a complicated way, particularly outside the core and in air gaps, where fringing fields and leakage flux must be considered.[src] Second, the magnetic field and force are nonlinear functions of the current, depending on the nonlinear relation between B and \mathbf{H} for the particular core material used.[src] For precise calculations, computer programs that can produce a model of the magnetic field using the finite element method are employed.[src] NI = H_{\mathrm{core}} L_{\mathrm{core}} + H_{\mathrm{gap}} L_{\mathrm{gap}} {{NumBlk|:| NI = B \left(\frac{L_{\mathrm{core}}}{\mu} + \frac{L_{\mathrm{gap}}}{\mu_0} \right) | }} This is a nonlinear equation, because the permeability of the core \mu varies with B .[src] For an exact solution, \mu(B) must be obtained from the core material hysteresis curve.[src] If B is unknown, the equation must be solved by numerical methods.[src] However, if the magnetomotive force is well above saturation (so the core material is in saturation), the magnetic field will be approximately the material's saturation value B_{sat} , and will not vary much with changes in NI .[src] For a closed magnetic circuit (no air gap), most core materials saturate at a magnetomotive force of roughly 800 ampere-turns per meter of flux path.[src] For most core materials, the relative permeability \mu_r \approx 2000 \text{–} 6000\, .[src] So in ( ), the second term dominates.[src] Therefore, in magnetic circuits with an air gap, B depends strongly on the length of the air gap, and the length of the flux path in the core does not matter much.[src] Given an air gap of 1mm, a magnetomotive force of about 796 ampere-turns is required to produce a magnetic field of 1 T.[src] m = \frac{NIA}{L} and thus the force between two poles is F = \frac{\mu_0 m_1 m_2}{4\pi r^2}.[src] Each electromagnet has two poles, so the total force on magnet 1 from magnet 2 is equal to the vector sum of the forces of magnet 2's poles acting on each pole of magnet 1.[src] ==Side effects== There are several side effects which occur in electromagnets, which must be considered in their design.[src] These effects generally become more significant in larger electromagnets.[src] ===Ohmic heating=== (Laboratoire National des Champs Magnétiques Intenses) high field laboratory The only power consumed in a direct current (DC) electromagnet under steady-state conditions is due to the resistance of the windings, and is dissipated as heat.[src] Some large electromagnets require water cooling systems in the windings to carry off the waste heat.[src] Since the magnetic field is proportional to the product NI , the number of turns in the windings N and the current I can be chosen to minimize heat losses, as long as their product is constant.[src] Since the power dissipation, P=I^2R , increases with the square of the current but only increases approximately linearly with the number of windings, the power lost in the windings can be minimized by reducing I and proportionally increasing the number of turns N , or using thicker wire to reduce the resistance.[src] For example, halving I and doubling N halves the power loss, as does doubling the area of the wire.[src] In either case, increasing the amount of wire reduces the ohmic losses.[src] For this reason, electromagnet windings often have a significant thickness.[src] However, the limit to increasing N or lowering the resistance is that the windings take up more space between the magnet's core pieces.[src] If the area available for windings is filled up, adding more turns requires a smaller diameter of wire, which has higher resistance, and thus cancels the advantage of using more turns.[src] So, in large magnets there is a minimum amount of heat loss that cannot be reduced.[src] This increases with the square of the magnetic flux, B^2 .[src] ===Inductive voltage spikes=== An electromagnet has significant inductance, and resists changes in the current through its windings.[src] Any sudden changes in the winding current cause large voltage spikes across the windings.[src] This is because when the current through the magnet is increased, such as when it is turned on, energy from the circuit must be stored in the magnetic field.[src] When it is turned off, the energy in the field is returned to the circuit.[src] If an ordinary switch is used to control the winding current, this can cause sparks at the terminals of the switch.[src] This does not occur when the magnet is switched on, because the limited supply voltage causes the current through the magnet and the field energy to increase slowly.[src] But when it is switched off, the energy in the magnetic field is suddenly returned to the circuit, causing a large voltage spike and an arc across the switch contacts, which can damage them.[src] With small electromagnets, a capacitor is sometimes used across the contacts, which reduces arcing by temporarily storing the current.[src] More often, a diode is used to prevent voltage spikes by providing a path for the current to recirculate through the winding until the energy is dissipated as heat.[src] The diode is connected across the winding, oriented so it is reverse-biased during steady state operation and does not conduct.[src] When the supply voltage is removed, the voltage spike forward-biases the diode and the reactive current continues to flow through the winding, through the diode, and back into the winding.[src] A diode used in this way is called a freewheeling diode or flyback diode.[src] Large electromagnets are usually powered by variable current electronic power supplies, controlled by a microprocessor, which prevent voltage spikes by accomplishing current changes slowly, in gentle ramps.[src] It may take several minutes to energize or deenergize a large magnet.[src] ===Lorentz forces=== In powerful electromagnets, the magnetic field exerts a force on each turn of the windings, due to the Lorentz force q\mathbf{v}\times\mathbf{B} acting on the moving charges within the wire.[src] The Lorentz force is perpendicular to both the axis of the wire and the magnetic field.[src] It can be visualized as a pressure between the magnetic field lines, pushing them apart.[src] It has two effects on an electromagnet's windings: The field lines within the axis of the coil exert a radial force on each turn of the windings, tending to push them outward in all directions.[src] This causes a tensile stress in the wire.[src] The leakage field lines between each turn of the coil exert an attractive force between adjacent turns, tending to pull them together.[src] The Lorentz forces increase with B^2 .[src] In large electromagnets the windings must be firmly clamped in place, to prevent motion on power-up and power-down from causing metal fatigue in the windings.[src] In the Bitter electromagnet design (Fig.[src] 2), used in very high-field research magnets, the windings are constructed as flat disks to resist the radial forces, and clamped in an axial direction to resist the axial ones.[src] ===Core losses=== In alternating current (AC) electromagnets, used in transformers, inductors, and AC motors and generators, the magnetic field is constantly changing.[src] This causes energy losses in their magnetic cores, which is dissipated as heat in the core.[src] The losses stem from two processes: eddy currents and hysteresis losses.[src] Eddy currents: From Faraday's law of induction, a changing magnetic field induces circulating electric currents (eddy currents) inside nearby conductors.[src] The energy in these currents is dissipated as heat in the electrical resistance of the conductor, so they are a cause of energy loss.[src] Since the magnet's iron core is conductive, and most of the magnetic field is concentrated there, eddy currents in the core are the major problem.[src] Eddy currents are closed loops of current that flow in planes perpendicular to the magnetic field.[src] The energy dissipated is proportional to the area enclosed by the loop.[src] To prevent them, the cores of AC electromagnets are made of stacks of thin steel sheets, or laminations, oriented parallel to the magnetic field, with an insulating coating on the surface.[src] The insulation layers prevent eddy current from flowing between the sheets.[src] Any remaining eddy currents must flow within the cross-section of each individual lamination, which reduces losses greatly.[src] Another alternative is to use a ferrite core, which is a nonconductor.[src] Hysteresis losses: Reversing the direction of magnetization of the magnetic domains in the core material each cycle causes energy loss, because of the coercivity of the material.[src] These are called hysteresis losses.[src] The energy lost per cycle is proportional to the area of the hysteresis loop in the BH graph.[src] To minimize this loss, magnetic cores used in transformers and other AC electromagnets are made of "soft" low coercivity materials, such as silicon steel or soft ferrite.[src] The energy loss per cycle of the alternating current is constant for each of these processes, so the power loss increases linearly with frequency.[src]

115 sentences · 115 cited inline · 0 references stored

References

No reference rows published for this article.

Cite this article

MLA

"Electromagnet." encyclopegia.org, 2026, https://encyclopegia.org/wiki/electromagnet. Accessed 28 November 2026.

Chicago

"Electromagnet." encyclopegia.org. Accessed November 28, 2026. https://encyclopegia.org/wiki/electromagnet.

APA

encyclopegia.org. (2026). Electromagnet. Retrieved November 28, 2026, from https://encyclopegia.org/wiki/electromagnet

Accessed November 28, 2026 · CC BY-SA 4.0 · citation page · JSON

Related articles

Bitter electromagnet

enwiki · references available
CC BY-SA 4.0 · share-alike · https://en.wikipedia.org/w/index.php?oldid=1374050891 · 0.5 · snapshot enwiki-001374050891

Cite · JSON · Search

Related services and records

Services

  • Estate — measured countries, lanes and facts
  • Intel — live corroborated events
  • Legal — statutes, cases and citations
  • Encyclopedia — articles with inline sources
  • Space — launches, satellites and orbits
  • Search — federated search and reports
  • Pass — passport account and SSO
  • Corpora — read-only corpus origins
  • e01 — self-hosted corpora and tools
  • Careers — open roles: frontier engineers and sales partners

Text and metadata only; each target carries its own sources. Missing data is published as no-data, never estimated.