Electrostatic force microscope

Electrostatic force microscopy (EFM) is a type of dynamic non-contact atomic force microscopy where the electrostatic force is probed. ("Dynamic" here means that the cantilever is oscillating and does not make contact with the sample). This force arises due to the attraction or repulsion of separated charges. It is a long-range force and can be detected 100 nm or more from the sample.

Electrostatic force microscopy (EFM) is a type of dynamic non-contact atomic force microscopy where the electrostatic force is probed. ("Dynamic" here means that the cantilever is oscillating and does not make contact with the sample). This force arises due to the attraction or repulsion of separated charges. It is a long-range force and can be detected 100 nm or more from the sample. ==Force measurement== For example, consider a conductive cantilever tip and sample which are separated a distance usually by a vacuum. A bias voltage between tip and sample is applied by an external battery forming a capacitor, , between the two. The capacitance of the system depends on the geometry of the tip and sample. The total energy stored in that capacitor is U = \frac{1}{2} \, C \, \Delta V^2. The work done by the battery to maintain a constant voltage, , between the capacitor plates (tip and sample) is . By definition, taking the negative gradient of the total energy gives the force. The component of the force (the force along the axis connecting the tip and sample) is thus: F_{\rm electrostatic} = \frac{1}{2} \frac{\partial C}{\partial z} \Delta V^2 . Since this force is always attractive. The electrostatic force can be probed by changing the voltage, and that force is parabolic with respect to the voltage. One note to make is that is not simply the voltage difference between the tip and sample. Since the tip and sample are often not the same material, and furthermore can be subject to trapped charges, debris, etc., there is a difference between the work functions of the two. This difference, when expressed in terms of a voltage, is called the contact potential difference, . This causes the apex of the parabola to rest at \Delta V = V_{\rm tip} - V_{\rm sample} - V_{\rm CPD} = 0. Typically, the value of is on the order of a few hundred millivolts. Forces as small as piconewtons can routinely be detected with this method. ==Non-contact atomic force microscopy== A common form of electric force microscopy involves a noncontact AFM mode of operation. In this mode the cantilever is oscillated at a resonant frequency of the cantilever and the AFM tip is held such that it only senses with long range electrostatic forces without entering the repulsive contact regime. In this non-contact regime, the electric force gradient causes a shift in the resonance frequency of the cantilever. EFM images can be created by measuring the cantilever oscillation, phase and/or frequency shift of the cantilever in response to the electrostatic force gradient. ==Immersion== With an electrostatic force microscope, like the atomic force microscope it is based on, the sample can be immersed in non-conductive liquid only, because conductive liquids hinder the establishment of an electrical potential difference that causes the detected electrostatic force.

References

  1. pnas.org . retrieved 2026-11-19 source revision 1359777013 · retrieved 2026-11-18 · rev 1359777013
    Cite this reference

    MLA "pnas.org . retrieved 2026-11-19 source revision 1359777013." pnas. 2026-11-18. https://en.wikipedia.org/w/index.php?oldid=1359777013. Accessed 24 November 2026.

    Chicago "pnas.org . retrieved 2026-11-19 source revision 1359777013." pnas. 2026-11-18. https://en.wikipedia.org/w/index.php?oldid=1359777013.

    APA pnas. (2026). pnas.org . retrieved 2026-11-19 source revision 1359777013. Retrieved November 24, 2026, from https://en.wikipedia.org/w/index.php?oldid=1359777013

  2. dx.doi.org . retrieved 2026-11-19 source revision 1359777013 · retrieved 2026-11-18 · rev 1359777013
    Cite this reference

    MLA "dx.doi.org . retrieved 2026-11-19 source revision 1359777013." dx. 2026-11-18. https://en.wikipedia.org/w/index.php?oldid=1359777013. Accessed 24 November 2026.

    Chicago "dx.doi.org . retrieved 2026-11-19 source revision 1359777013." dx. 2026-11-18. https://en.wikipedia.org/w/index.php?oldid=1359777013.

    APA dx. (2026). dx.doi.org . retrieved 2026-11-19 source revision 1359777013. Retrieved November 24, 2026, from https://en.wikipedia.org/w/index.php?oldid=1359777013

Cite this article

MLA

"Electrostatic force microscope." encyclopegia.org, 2026, https://encyclopegia.org/wiki/electrostatic-force-microscope. Accessed 24 November 2026.

Chicago

"Electrostatic force microscope." encyclopegia.org. Accessed November 24, 2026. https://encyclopegia.org/wiki/electrostatic-force-microscope.

APA

encyclopegia.org. (2026). Electrostatic force microscope. Retrieved November 24, 2026, from https://encyclopegia.org/wiki/electrostatic-force-microscope

Accessed November 24, 2026 · CC BY-SA 4.0 · citation page · JSON

Related articles

R Force

stub · references available

Royal Air Force

stub · references available

Force India VJM04

stub · references available

scanning tunneling microscope

stub · references available

Central Air Force Museum

stub · references available

kilogram-force

stub · references available

Internet Engineering Task Force

stub · references available

Abraham–Lorentz force

stub · references available
CC BY-SA 4.0 · share-alike · https://en.wikipedia.org/w/index.php?oldid=1359777013 · 0.5 · snapshot enwiki-001359777013

Cite · JSON · Search

Related services and records

Services

  • Estate — measured countries, lanes and facts
  • Intel — live corroborated events
  • Legal — statutes, cases and citations
  • Encyclopedia — articles with inline sources
  • Space — launches, satellites and orbits
  • Search — federated search and reports
  • Pass — passport account and SSO
  • Corpora — read-only corpus origins
  • e01 — self-hosted corpora and tools

Text and metadata only; each target carries its own sources. Missing data is published as no-data, never estimated.