Explosimeter
An explosimeter is a gas detector which is used to measure the amount of combustible gases present in a sample. When a percentage of the lower explosive limit (LEL) of an atmosphere is exceeded, an alarm signal on the instrument is activated. The device, also called a combustible gas detector, operates on the principle of resistance proportional to heat—a wire is heated, and a sample of the gas is introduced to the hot wire. Combustible gases burn in the presence of the hot wire, thus increasing the resistance and disturbing a Wheatstone bridge, which gives the reading. A flashback arrestor is installed in the device to avoid the explosimeter igniting the sample external to the device. Note, that the detection readings of an explosimeter are only accurate if the gas being sampled has the same characteristics and response as the calibration gas. Most explosimeters are calibrated to methane, hydrogen, and carbon monoxide. Explosimeters are important because workspaces may contain a flammable or explosive atmosphere due to the accumulation of flammable gases or vapors. Sparks from ordinary battery-powered portable equipment, including cameras, cell phones, laptop computers, or anything else located on the job site may serve as an ignition source. The explosimeter warns the user of dangerous atmospheric conditions before a possible explosion can occur.
An explosimeter is a gas detector which is used to measure the amount of combustible gases present in a sample. When a percentage of the lower explosive limit (LEL) of an atmosphere is exceeded, an alarm signal on the instrument is activated. The device, also called a combustible gas detector, operates on the principle of resistance proportional to heat—a wire is heated, and a sample of the gas is introduced to the hot wire. Combustible gases burn in the presence of the hot wire, thus increasing the resistance and disturbing a Wheatstone bridge, which gives the reading. A flashback arrestor is installed in the device to avoid the explosimeter igniting the sample external to the device. Note, that the detection readings of an explosimeter are only accurate if the gas being sampled has the same characteristics and response as the calibration gas. Most explosimeters are calibrated to methane, hydrogen, and carbon monoxide. Explosimeters are important because workspaces may contain a flammable or explosive atmosphere due to the accumulation of flammable gases or vapors. Sparks from ordinary battery-powered portable equipment, including cameras, cell phones, laptop computers, or anything else located on the job site may serve as an ignition source. The explosimeter warns the user of dangerous atmospheric conditions before a possible explosion can occur. ==References== == External links== https://web.archive.org/web/20050910075254/http://www.marineengineering.org.uk/testequipment/explosimeter.htm (select explosimeter from the left frame) Explosimetry
References
- OSHA Technical Manual (OTM) Section II: Chapter 3 · retrieved 2026-11-17 · rev 1288493721
Cite this reference
MLA "OSHA Technical Manual (OTM) Section II: Chapter 3." 2026-11-17. https://www.osha.gov/otm/section-2-health-hazards/chapter-3#Introduction. Accessed 24 November 2026.
Chicago "OSHA Technical Manual (OTM) Section II: Chapter 3." 2026-11-17. https://www.osha.gov/otm/section-2-health-hazards/chapter-3#Introduction.
APA encyclopegia.org. (2026). OSHA Technical Manual (OTM) Section II: Chapter 3. Retrieved November 24, 2026, from https://www.osha.gov/otm/section-2-health-hazards/chapter-3#Introduction
- Coleman, E. H. (1960). MEMORANDUM ON THE CHOICE AND USE OF EXPLOSIMETERS . Boreham Wood, England: DEPARTMENT OF SCIENTIFIC AND INDUSTRIAL RESEARCH AND FIRE OFFICES COMMITTEE JOINT FIRE RESEARCH ORGANIZATION. pp. 1– 2. Wikipedia revision 1288493721, retrieved 2026-11-18 · retrieved 2026-11-17 · rev 1288493721
Cite this reference
MLA "Coleman, E. H. (1960). MEMORANDUM ON THE CHOICE AND USE OF EXPLOSIMETERS . Boreham Wood, England: DEPARTMENT OF SCIENTIFIC AND INDUSTRIAL RESEARCH AND FIRE OFFICES COMMITTEE JOINT FIRE RESEARCH ORGANIZATION. pp. 1– 2. Wikipedia revision 1288493721, retrieved 2026-11-18." Coleman, E. 2026-11-17. https://en.wikipedia.org/w/index.php?oldid=1288493721. Accessed 24 November 2026.
Chicago "Coleman, E. H. (1960). MEMORANDUM ON THE CHOICE AND USE OF EXPLOSIMETERS . Boreham Wood, England: DEPARTMENT OF SCIENTIFIC AND INDUSTRIAL RESEARCH AND FIRE OFFICES COMMITTEE JOINT FIRE RESEARCH ORGANIZATION. pp. 1– 2. Wikipedia revision 1288493721, retrieved 2026-11-18." Coleman, E. 2026-11-17. https://en.wikipedia.org/w/index.php?oldid=1288493721.
APA Coleman, E. (2026). Coleman, E. H. (1960). MEMORANDUM ON THE CHOICE AND USE OF EXPLOSIMETERS . Boreham Wood, England: DEPARTMENT OF SCIENTIFIC AND INDUSTRIAL RESEARCH AND FIRE OFFICES COMMITTEE JOINT FIRE RESEARCH ORGANIZATION. pp. 1– 2. Wikipedia revision 1288493721, retrieved 2026-11-18. Retrieved November 24, 2026, from https://en.wikipedia.org/w/index.php?oldid=1288493721
- Yaws, Carl L.; Braker, William (2001). Matheson gas data book . New York: Matheson Tri-Gas. ISBN 9780071358545 . Wikipedia revision 1288493721, retrieved 2026-11-18 · retrieved 2026-11-17 · rev 1288493721
Cite this reference
MLA "Yaws, Carl L.; Braker, William (2001). Matheson gas data book . New York: Matheson Tri-Gas. ISBN 9780071358545 . Wikipedia revision 1288493721, retrieved 2026-11-18." Yaws, Carl L. 2026-11-17. https://en.wikipedia.org/wiki/ISBN_(identifier). Accessed 24 November 2026.
Chicago "Yaws, Carl L.; Braker, William (2001). Matheson gas data book . New York: Matheson Tri-Gas. ISBN 9780071358545 . Wikipedia revision 1288493721, retrieved 2026-11-18." Yaws, Carl L. 2026-11-17. https://en.wikipedia.org/wiki/ISBN_(identifier).
APA Yaws, Carl L. (2026). Yaws, Carl L.; Braker, William (2001). Matheson gas data book . New York: Matheson Tri-Gas. ISBN 9780071358545 . Wikipedia revision 1288493721, retrieved 2026-11-18. Retrieved November 24, 2026, from https://en.wikipedia.org/wiki/ISBN_(identifier)
- Don't Underestimate the Importance of LEL Correlation Factors - · retrieved 2025-03-17 · rev 1288493721
Cite this reference
MLA "Don't Underestimate the Importance of LEL Correlation Factors -." a b Jubeck, Scott (May 1, 2014). 2025-03-17. https://ohsonline.com/Articles/2014/05/01/LEL-Correlation-Factors.aspx?Page=1. Accessed 24 November 2026.
Chicago "Don't Underestimate the Importance of LEL Correlation Factors -." a b Jubeck, Scott (May 1, 2014). 2025-03-17. https://ohsonline.com/Articles/2014/05/01/LEL-Correlation-Factors.aspx?Page=1.
APA a b Jubeck, Scott (May 1, 2014). (2025). Don't Underestimate the Importance of LEL Correlation Factors -. Retrieved November 24, 2026, from https://ohsonline.com/Articles/2014/05/01/LEL-Correlation-Factors.aspx?Page=1
Cite this article
MLA
"Explosimeter." encyclopegia.org, 2025, https://encyclopegia.org/wiki/explosimeter. Accessed 24 November 2026.
Chicago
"Explosimeter." encyclopegia.org. Accessed November 24, 2026. https://encyclopegia.org/wiki/explosimeter.
APA
encyclopegia.org. (2025). Explosimeter. Retrieved November 24, 2026, from https://encyclopegia.org/wiki/explosimeter
Accessed November 24, 2026 · CC BY-SA 4.0 · citation page · JSON