False coverage rate
In statistics, a false coverage rate (FCR) is the average rate of false coverage, i.e.[src] not covering the true parameters, among the selected intervals.[src] The FCR gives a simultaneous coverage at a (1 − α)×100% level for all of the parameters considered in the problem.[src] The FCR has a strong connection to the false discovery rate (FDR).[src] Both methods address the problem of multiple comparisons, FCR from confidence intervals (CIs) and FDR from P-value's point of view.[src] FCR was needed because of dangers caused by selective inference.[src] Researchers and scientists tend to report or highlight only the portion of data that is considered significant without clearly indicating the various hypothesis that were considered.[src] It is therefore necessary to understand how the data is falsely covered.[src] There are many FCR procedures which can be used depending on the length of the CI – Bonferroni-selected–Bonferroni-adjusted, Adjusted BH-Selected CIs (Benjamini and Yekutieli 2005 ).[src] The incentive of choosing one procedure over another is to ensure that the CI is as narrow as possible and to keep the FCR.[src] For microarray experiments and other modern applications, there are a huge number of parameters, often tens of thousands or more and it is very important to choose the most powerful procedure.[src] The FCR was first introduced by Daniel Yekutieli in his PhD thesis in 2001.[src]
In statistics, a false coverage rate (FCR) is the average rate of false coverage, i.e.[src] not covering the true parameters, among the selected intervals.[src] The FCR gives a simultaneous coverage at a (1 − α)×100% level for all of the parameters considered in the problem.[src] The FCR has a strong connection to the false discovery rate (FDR).[src] Both methods address the problem of multiple comparisons, FCR from confidence intervals (CIs) and FDR from P-value's point of view.[src] FCR was needed because of dangers caused by selective inference.[src] Researchers and scientists tend to report or highlight only the portion of data that is considered significant without clearly indicating the various hypothesis that were considered.[src] It is therefore necessary to understand how the data is falsely covered.[src] There are many FCR procedures which can be used depending on the length of the CI – Bonferroni-selected–Bonferroni-adjusted, Adjusted BH-Selected CIs (Benjamini and Yekutieli 2005 ).[src] The incentive of choosing one procedure over another is to ensure that the CI is as narrow as possible and to keep the FCR.[src] For microarray experiments and other modern applications, there are a huge number of parameters, often tens of thousands or more and it is very important to choose the most powerful procedure.[src] The FCR was first introduced by Daniel Yekutieli in his PhD thesis in 2001.[src] ==Definitions== Not keeping the FCR means \text{FCR}>q when q= \frac{V}{R} = \frac{\alpha m_0}{R} , where m_0 is the number of true null hypotheses, R is the number of rejected hypothesis, V is the number of false positives, and \alpha is the significance level.[src] Intervals with simultaneous coverage probability 1-q can control the FCR to be bounded by q .[src] ===Classification of multiple hypothesis tests=== ==The problems addressed by FCR== ===Selection=== Selection causes reduced average coverage.[src] Selection can be presented as conditioning on an event defined by the data and may affect the coverage probability of a CI for a single parameter.[src] Equivalently, the problem of selection changes the basic sense of P-values.[src] FCR procedures consider that the goal of conditional coverage following any selection rule for any set of (unknown) values for the parameters is impossible to achieve.[src] A weaker property when it comes to selective CIs is possible and will avoid false coverage statements.[src] FCR is a measure of interval coverage following selection.[src] Therefore, even though a 1 − α CI does not offer selective (conditional) coverage, the probability of constructing a no covering CI is at most α, where \Pr[\theta \not\in \mathrm{CI},\ \text{CI constructed}] \leq \Pr[\theta \not\in \mathrm{CI}] \leq \alpha ===Selection and multiplicity=== When facing both multiplicity (inference about multiple parameters) and selection, not only is the expected proportion of coverage over selected parameters at 1−α not equivalent to the expected proportion of no coverage at α, but also the latter can no longer be ensured by constructing marginal CIs for each selected parameter.[src] FCR procedures solve this by taking the expected proportion of parameters not covered by their CIs among the selected parameters, where the proportion is 0 if no parameter is selected.[src] This false coverage-statement rate (FCR) is a property of any procedure that is defined by the way in which parameters are selected and the way in which the multiple intervals are constructed.[src] ==Controlling procedures== ===Bonferroni procedure (Bonferroni-selected–Bonferroni-adjusted) for simultaneous CI=== Simultaneous CIs with Bonferroni procedure when we have m parameters, each marginal CI constructed at the 1 − α/m level.[src] Without selection, these CIs offer simultaneous coverage, in the sense that the probability that all CIs cover their respective parameters is at least 1 − α.[src] unfortunately, even such a strong property does not ensure the conditional confidence property following selection.[src] ===FCR for Bonferroni-selected–Bonferroni-adjusted simultaneous CI=== The Bonferroni–Bonferroni procedure cannot offer conditional coverage, however it does control the FCR at <α In fact it does so too well, in the sense that the FCR is much too close to 0 for large values of θ.[src] Intervals selection is based on Bonferroni testing, and Bonferroni CIs are then constructed.[src] The FCR is estimated as, the proportion of intervals failing to cover their respective parameters among the constructed CIs is calculated (setting the proportion to 0 when none are selected).[src] Where selection is based on unadjusted individual testing and unadjusted CIs are constructed.[src] ===FCR-adjusted BH-selected CIs=== In BH procedure for FDR after sorting the p values P(1) ≤ • • • ≤ P(m) and calculating R = max{ j : P( j) ≤ j • q/m}, the R null hypotheses for which P(i) ≤ R • q/m are rejected.[src] If testing is done using the Bonferroni procedure, then the lower bound of the FCR may drop well below the desired level q, implying that the intervals are too long.[src] In contrast, applying the following procedure, which combines the general procedure with the FDR controlling testing in the BH procedure, also yields a lower bound for the FCR, q/2 ≤ FCR.[src] This procedure is sharp in the sense that for some configurations, the FCR approaches q.[src] 1.[src] Sort the p values used for testing the m hypotheses regarding the parameters, P(1) ≤ • • • ≤P(m).[src] 2.[src] Calculate R = max{i : P(i) ≤ i • q/m}.[src] 3.[src] Select the R parameters for which P(i) ≤ R • q/m, corresponding to the rejected hypotheses.[src] 4.[src] Construct a 1 − R • q/m CI for each parameter selected.[src] ==See also== False positive rate Post-hoc analysis[src]
55 sentences · 55 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"False coverage rate." encyclopegia.org, 2025, https://encyclopegia.org/wiki/false-coverage-rate. Accessed 29 November 2026.
Chicago
"False coverage rate." encyclopegia.org. Accessed November 29, 2026. https://encyclopegia.org/wiki/false-coverage-rate.
APA
encyclopegia.org. (2025). False coverage rate. Retrieved November 29, 2026, from https://encyclopegia.org/wiki/false-coverage-rate
Accessed November 29, 2026 · CC BY-SA 4.0 · citation page · JSON