Fault indicator
A fault indicator is a mechanism that conveys an indication of a fault, or absence of it, in a system.[src] For example, the purpose of the engine-check light commonly found on the dashboard of motor vehicles is to indicate whether or not there is a fault with the engine.[src]
A fault indicator is a mechanism that conveys an indication of a fault, or absence of it, in a system.[src] For example, the purpose of the engine-check light commonly found on the dashboard of motor vehicles is to indicate whether or not there is a fault with the engine.[src] ==Electric power distribution networks== In electric power distribution networks, a fault indicator is a device which provides visual or remote indication of a fault on the electric power system.[src] Also called a faulted circuit indicator (FCI), the device is used in electric power distribution networks as a means of automatically detecting and identifying faults to reduce outage time.[src] Overhead indicators are used to visualize the occurrence of an electrical fault on an overhead electrical system.[src] Underground indicators locate faults on an underground system.[src] Often these devices are located in an underground vault.[src] Some fault indicators communicate back to a central location using radio or cellular signals.[src] ===Basic principles=== conductor mounted fault indicator.[src] 11 kV distribution network with compensated neutral at Ataahua, New Zealand]] Typically fault indicators sense magnetic field caused by current flows through a conductor or cable.[src] Some of them also use measurement of electric field caused by voltage in conductor.[src] During an electrical fault on a grounded system, additional current flows through a conductor, inducing a magnetic field, which is detected up by the fault indicator causing a state change on the mechanical target flag, LED, or remote indication device.[src] Ground fault indicators for isolated ground systems sense the vector sum of the current and look for an imbalance indicating a fault on one or more of the three phases.[src] Systems with earthing through high resistance have low phase-to-ground fault currents so require high sensitivity of fault indication (FI).[src] When there are high load currents and low earth fault levels the line mounted fault indicators should look at the differential increase of the current instead of the absolute value.[src] In insulated neutral systems and systems with earthing through a Petersen coil, ground faults cannot be located with classical FI's at all.[src] Capacitive current appears in overall faulted system so directional fault location devices are required.[src] Upon energization of the lines there could be high inrush current which may lead the fault indicators to false operation.[src] Some fault indicators can block inrush current.[src] Advanced fault indicators should monitor the live line to distinguish fault currents from usual current surges.[src] They operate only after making sure of the feeding circuit breaker/fuse has cut the power flow and the line is de-energized.[src] To monitor the live line, some fault indicators look only at the magnetic field caused by the load current.[src] To be independent from the load current, some FI’s look at the electric field to check the voltage directly.[src] This feature is used to reset the indicator after the line is re-energized too.[src] Such indicators can also distinguish permanent faults from transient faults.[src] Some modern network protection systems have time to clear a fault as small as possible down to 60 ms so fault indicators must not only be highly sensitive and directional but additionally very fast.[src] Modern fault indicators can detect faults with the duration of one cycle 18–20 ms.[src] In the networks with low earth fault levels the indicators are required to be set to low values.[src] In such cases the user should consider the downstream capacitive discharge current to avoid false operation of the non-directional indicators.[src] Some overhead line fault indicators called as pole mounted fault indicators can detect the live line and the fault current from below the conductors.[src] High-voltage fuses commonly drop down after operating, making it obvious where the fault is.[src] However, fuses are rarely equipped with remote communication.[src] ===History=== The first fault indicators were brought onto the market by Horstmann from Germany in 1946.[src] The Schweitzer Manufacturing Company (now a division of Schweitzer Engineering Laboratories) introduced a product to the United States in 1948.[src] The first fault indicators were manual reset devices.[src] Later fault indicators automatically reset on system restoration or after a set period of time.[src] More recent fault indicators communicate their status (tripped or reset) via cell signal or radio to a central station, handheld device, or pole-mounted receiver.[src] Recent developments include a remotely programmable overhead line indicator, fault indication for paper-insulated lead cable, and an overhead fault indicator for mesh networks.[src] ==References==[src]
41 sentences · 41 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"Fault indicator." encyclopegia.org, 2026, https://encyclopegia.org/wiki/fault-indicator. Accessed 26 November 2026.
Chicago
"Fault indicator." encyclopegia.org. Accessed November 26, 2026. https://encyclopegia.org/wiki/fault-indicator.
APA
encyclopegia.org. (2026). Fault indicator. Retrieved November 26, 2026, from https://encyclopegia.org/wiki/fault-indicator
Accessed November 26, 2026 · CC BY-SA 4.0 · citation page · JSON