In electrical engineering, the Ferranti effect is the increase in voltage occurring at the receiving end of a very long (> 200 km) AC electric power transmission line, relative to the voltage at the sending end, when the load is very small, or no load is connected.[src] It can be stated as a factor, or as a percent increase.[src] It was first observed during the installation of underground cables in Sebastian Ziani de Ferranti's 10,000-volt AC power distribution system in 1887.[src] The capacitive line charging current produces a voltage drop across the line inductance that is in-phase with the sending-end voltage, assuming negligible line resistance.[src] Therefore, both line inductance and capacitance are responsible for this phenomenon.[src] This can be analysed by considering the line as a transmission line where the source impedance is lower than the load impedance (unterminated).[src] The effect is similar to an electrically short version of the quarter-wave impedance transformer, but with smaller voltage transformation.[src] The Ferranti effect is more pronounced the longer the line and the higher the voltage applied.[src] The relative voltage rise is proportional to the square of the line length and the square of frequency.[src] The Ferranti effect is much more pronounced in underground cables, even in short lengths, because of their high capacitance per unit length, and lower electrical impedance.…[src]
In electrical engineering, the Ferranti effect is the increase in voltage occurring at the receiving end of a very long (> 200 km) AC electric power transmission line, relative to the voltage at the sending end, when the load is very small, or no load is connected.[src] It can be stated as a factor, or as a percent increase.[src] It was first observed during the installation of underground cables in Sebastian Ziani de Ferranti's 10,000-volt AC power distribution system in 1887.[src] The capacitive line charging current produces a voltage drop across the line inductance that is in-phase with the sending-end voltage, assuming negligible line resistance.[src] Therefore, both line inductance and capacitance are responsible for this phenomenon.[src] This can be analysed by considering the line as a transmission line where the source impedance is lower than the load impedance (unterminated).[src] The effect is similar to an electrically short version of the quarter-wave impedance transformer, but with smaller voltage transformation.[src] The Ferranti effect is more pronounced the longer the line and the higher the voltage applied.[src] The relative voltage rise is proportional to the square of the line length and the square of frequency.[src] The Ferranti effect is much more pronounced in underground cables, even in short lengths, because of their high capacitance per unit length, and lower electrical impedance.[src] An equivalent to the Ferranti effect occurs when inductive current flows through a series capacitance.[src] Indeed, a 90^\circ lagging current -jI_L flowing through a -jX_c impedance results in a voltage difference V_\text{send} - V_\text{receive}=(-jI_L)(-jX_c)=-I_L X_c , hence in increased voltage on the receiving side.[src] ==See also== LC circuit "A series resonant circuit provides voltage magnification." Reflections of signals on conducting lines Failure of the first trans-Atlantic telegraph cable Telegrapher's equations Characteristic impedance#Transmission line model ==References==[src]
23 sentences · 23 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"Ferranti effect." encyclopegia.org, 2023, https://encyclopegia.org/wiki/ferranti-effect. Accessed 25 November 2026.
Chicago
"Ferranti effect." encyclopegia.org. Accessed November 25, 2026. https://encyclopegia.org/wiki/ferranti-effect.
APA
encyclopegia.org. (2023). Ferranti effect. Retrieved November 25, 2026, from https://encyclopegia.org/wiki/ferranti-effect
Accessed November 25, 2026 · CC BY-SA 4.0 · citation page · JSON