encyclopegia.org

Fire pump

in 1818 ; ca.[src] 1977 A fire pump usually refers to a pressure-increasing component of the water supply for fixed-place fire suppression systems such as fire sprinklers, standpipes, and foam systems.[src] Fire pumps are also a critical component integrated into fire trucks and fire boats, and serve a similar purpose boosting water supplies for firefighting hose operations.[src]

in 1818]] ; ca.[src] 1977]] A fire pump usually refers to a pressure-increasing component of the water supply for fixed-place fire suppression systems such as fire sprinklers, standpipes, and foam systems.[src] Fire pumps are also a critical component integrated into fire trucks and fire boats, and serve a similar purpose boosting water supplies for firefighting hose operations.[src] ==Description== Fire pumps are used to increase the pressure of water sourced from a municipal underground water supply piping network, or a static supply (e.g., tank, reservoir, lake).[src] A fire pump is a centrifugal- or positive displacement- pump that has been tested and listed by a third-party testing and listing agency, such as UL or FM Global specifically for fire service use.[src] The main standard that governs fire pump fixed-place installations in North America is the National Fire Protection Association's NFPA 20 Standard for the Installation of Stationary Fire Pumps for Fire Protection.[src] Fire pumps are powered most commonly by an electric motor or a diesel engine, or, occasionally a steam turbine.[src] If the governing model building code requires backup power independent of the local electric power grid, a fire pump using an electric motor may utilize an emergency generator when connected via a listed transfer switch.[src] Fire pumps installed on fire trucks and boats are powered by the engine of the vehicle/vessel.[src] Utilizing a control panel with pressure sensors, fire pumps automatically start when the pressure in the fire sprinkler system drops below a pre-designated threshold.[src] Given the incompressibility of water, fire suppression system pressures drops significantly and quickly when one or more outlets open.[src] Examples would be fused (opened) fire sprinklers, fire hose valves connected to a standpipe, or automatic control valves opened by release panels.[src] Fire pumps are utilized when determined by hydraulic calculations that the existing water supply cannot provide sufficient pressure to meet the hydraulic design requirements of the suppression system.[src] This usually occurs if the building is very tall, such as in high-rise buildings (to overcome hydraulic head losses created from elevation differences), in systems that require a relatively high terminal pressure at the fire suppression outlets (to provide sufficient water droplet penetration of a fire plume), or in systems that require a large discharge of water (such as storage warehouses).[src] Fire pumps are also needed if fire protection water supply is provided from a static source which provides little or no pressure.[src] Some situations may be compounded by all of these factors, requiring large water supplies and powerful fire pumps.[src] Common types of fire pumps used for fire service include: horizontal split case, vertical split case, vertical inline, vertical turbine, and end suction.[src] ==Fire pumps, circulation relief valve== Each pump shall have a circulation relief valve listed for the fire pump service installed and set below the shutoff pressure at minimum expected suction pressure.[src] Exception: This rule shall not apply to engine-driven pumps for which engine cooling water is taken from the pump discharge.[src] ==Jockey pump== A jockey pump, also known as a pressure-maintenance pump, is a small pump connected to a fire suppression system near the fire pump and is intended to maintain pressure in a fire protection piping system.[src] These pumps recover pressures lost from gradual, slow pressure declines in a system due to temperature changes, trapped air escapement, or very small leaks.[src] The jockey pump is essentially a portion of the fire pump's control system.[src] A jockey pump is sized for a flow less than one sprinkler in order to ensure a system pressure drop significant enough to start the main fire pump.[src] Jockey pumps are typically small multistage centrifugal pumps, and do not have to be listed or certified for fire system application.[src] The control equipment for jockey pumps may however carry approvals.[src] Jockey pumps should be sized for 3% of the flow of the main fire pump and to provide 10psi more pressure than the main fire pump (As per Code IS 15105 : 2002) In the United States, the application of a jockey pump in a fire protection system is provided by NFPA 20.[src] They are inspected per NFPA 25 "Inspection and Testing of Water-Based Fire Protection Systems".[src] In India, the pump manufacturers generally adhere to the TAC (Tariff Advisory Committee) guidelines, although pump manufacturers also obtain listings with UL or FM Global.[src] For the purpose of installation & maintenance of fire-fighting pumps, Bureau of Indian Standards has published IS 15301 which is being followed throughout India.[src]

32 sentences · 32 cited inline · 0 references stored

References

No reference rows published for this article.

Cite this article

MLA

"Fire pump." encyclopegia.org, 2025, https://encyclopegia.org/wiki/fire-pump. Accessed 25 November 2026.

Chicago

"Fire pump." encyclopegia.org. Accessed November 25, 2026. https://encyclopegia.org/wiki/fire-pump.

APA

encyclopegia.org. (2025). Fire pump. Retrieved November 25, 2026, from https://encyclopegia.org/wiki/fire-pump

Accessed November 25, 2026 · CC BY-SA 4.0 · citation page · JSON

Related articles

Project:Village pump

stub · references available

Pacific Ring of Fire

stub · references available

Buncefield fire

stub · references available

Alcalá 20 nightclub fire

stub · references available

Earth, Wind & Fire

stub · references available

A Fire Upon the Deep

stub · references available

Chariots of Fire

stub · references available
CC BY-SA 4.0 · share-alike · https://en.wikipedia.org/w/index.php?oldid=1308382030 · 0.5 · snapshot enwiki-001308382030

Cite · JSON · Search

Related services and records

Services

  • Estate — measured countries, lanes and facts
  • Intel — live corroborated events
  • Legal — statutes, cases and citations
  • Encyclopedia — articles with inline sources
  • Space — launches, satellites and orbits
  • Search — federated search and reports
  • Pass — passport account and SSO
  • Corpora — read-only corpus origins
  • e01 — self-hosted corpora and tools

Text and metadata only; each target carries its own sources. Missing data is published as no-data, never estimated.