Fizeau interferometer
A Fizeau interferometer is an interferometric arrangement whereby two reflecting surfaces are placed facing each other.[src] As seen in Fig 1, the rear-surface reflected light from the transparent first reflector is combined with front-surface reflected light from the second reflector to form interference fringes.[src] The term Fizeau interferometer also refers to an interferometric arrangement used by Hippolyte Fizeau in a famous 1851 experiment that seemingly supported the partial ether-drag hypothesis of Augustin Jean Fresnel, but which ultimately played an instrumental role in bringing about a crisis in physics that led to Einstein's development of the theory of special relativity.[src] See Fizeau experiment.[src]
A Fizeau interferometer is an interferometric arrangement whereby two reflecting surfaces are placed facing each other.[src] As seen in Fig 1, the rear-surface reflected light from the transparent first reflector is combined with front-surface reflected light from the second reflector to form interference fringes.[src] The term Fizeau interferometer also refers to an interferometric arrangement used by Hippolyte Fizeau in a famous 1851 experiment that seemingly supported the partial ether-drag hypothesis of Augustin Jean Fresnel, but which ultimately played an instrumental role in bringing about a crisis in physics that led to Einstein's development of the theory of special relativity.[src] See Fizeau experiment.[src] ==Applications== Fizeau interferometers are commonly used for measuring the shape of an optical surface: Typically, a fabricated lens or mirror is compared to a reference piece having the desired shape.[src] In Fig.[src] 1, the Fizeau interferometer is shown as it might be set up to test an optical flat.[src] A precisely figured reference flat is placed on top of the flat being tested, separated by narrow spacers.[src] The reference flat is slightly beveled (only a fraction of a degree of beveling is necessary) to prevent the rear surface of the flat from producing interference fringes.[src] A collimated beam of monochromatic light illuminates the two flats, and a beam splitter allows the fringes to be viewed on-axis.[src] The reference piece is sometimes realized by a diffractive optical element (computer-generated hologram or CGH), as this can be manufactured by high accuracy lithographic methods.[src] Fig. 2 illustrates the use of CGHs in testing.[src] Unlike the figure, actual CGHs have line spacing on the order of 1 to 10 μm.[src] When laser light is passed through the CGH, the zero-order diffracted beam experiences no wavefront modification.[src] The wavefront of the first-order diffracted beam, however, is modified to match the desired shape of the test surface.[src] In the illustrated Fizeau interferometer test setup, the zero-order diffracted beam is directed towards the spherical reference surface, and the first-order diffracted beam is directed towards the test surface in such a way that the two reflected beams combine to form interference fringes.[src] Fizeau interferometers are also used in fiber optic sensors for measuring pressure, temperature, strain, etc.[src] ==Fizeau's ether-drag experiment== ===Significance=== .]] In 1851, Fizeau used an entirely different form of interferometer to measure the effect of movement of a medium upon the speed of light, as seen in Fig. 3.[src] According to the theories prevailing at the time, light traveling through a moving medium would be dragged along by the medium, so the measured speed of the light would be a simple sum of its speed through the medium plus the speed of the medium.[src] Fizeau indeed detected a dragging effect, but the magnitude of the effect that he observed was far lower than expected.[src] His results seemingly supported the partial ether-drag hypothesis of Fresnel, a situation that was disconcerting to most physicists.[src] Over half a century passed before a satisfactory explanation of Fizeau's unexpected measurement was developed with the advent of Einstein's theory of special relativity.[src] ===Experimental setup=== Light reflected from the tilted beam splitter is made parallel using a lens and split by slits into two beams, which traverse a tube carrying water moving with velocity v.[src] Each beam travels a different leg of the tube, is reflected at the mirror at left, and returns through the opposite leg of the tube.[src] Thus, both beams travel the same path, but one in the direction of flow of the water, and the other opposing the flow.[src] The two beams are recombined at the detector, forming an interference pattern that depends upon any difference in time traveling the two paths.[src] The interference pattern can be analyzed to determine the speed of light traveling along each leg of the tube.[src] ==See also== Hippolyte Fizeau List of types of interferometers ==References== ==External links== Some typical measurement setups from the booklet of interferometer manufacturer Zygo Corp.[src]
32 sentences · 32 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"Fizeau interferometer." encyclopegia.org, 2025, https://encyclopegia.org/wiki/fizeau-interferometer. Accessed 26 November 2026.
Chicago
"Fizeau interferometer." encyclopegia.org. Accessed November 26, 2026. https://encyclopegia.org/wiki/fizeau-interferometer.
APA
encyclopegia.org. (2025). Fizeau interferometer. Retrieved November 26, 2026, from https://encyclopegia.org/wiki/fizeau-interferometer
Accessed November 26, 2026 · CC BY-SA 4.0 · citation page · JSON