Flow cytometry
Flow cytometry (FC) is a technique used to detect and measure the physical and chemical characteristics of a population of cells or particles.[src] In this process, a sample containing cells or particles is suspended in a fluid and injected into the flow cytometer instrument.[src] The sample is focused to ideally flow one cell at a time through a laser beam, where the light scattered is characteristic to the cells and their components.[src] Cells are often labeled with fluorescent markers so light is absorbed and then emitted in a band of wavelengths.[src] Tens of thousands of cells can be quickly examined and the data gathered are processed by a computer.[src] Flow cytometry is routinely used in basic research, clinical practice, and clinical trials.[src] Uses for flow cytometry include: * Cell counting * Cell sorting * Determining cell characteristics and function * Detecting microorganisms * Biomarker detection * Protein engineering detection * Diagnosis of health disorders such as blood cancers * Measuring genome size A flow cytometry analyzer is an instrument that provides quantifiable data from a sample.[src] Other instruments using flow cytometry include cell sorters which physically separate and thereby purify cells of interest based on their optical properties.[src]
Flow cytometry (FC) is a technique used to detect and measure the physical and chemical characteristics of a population of cells or particles.[src] In this process, a sample containing cells or particles is suspended in a fluid and injected into the flow cytometer instrument.[src] The sample is focused to ideally flow one cell at a time through a laser beam, where the light scattered is characteristic to the cells and their components.[src] Cells are often labeled with fluorescent markers so light is absorbed and then emitted in a band of wavelengths.[src] Tens of thousands of cells can be quickly examined and the data gathered are processed by a computer.[src] Flow cytometry is routinely used in basic research, clinical practice, and clinical trials.[src] Uses for flow cytometry include: Cell counting Cell sorting Determining cell characteristics and function Detecting microorganisms Biomarker detection Protein engineering detection Diagnosis of health disorders such as blood cancers Measuring genome size A flow cytometry analyzer is an instrument that provides quantifiable data from a sample.[src] Other instruments using flow cytometry include cell sorters which physically separate and thereby purify cells of interest based on their optical properties.[src] ===Name of the technology=== The original name of the fluorescence-based flow cytometry technology was "pulse cytophotometry" (German: Impulszytophotometrie), based on the first patent application on fluorescence-based flow cytometry.[src] At the 5th American Engineering Foundation Conference on Automated Cytology in Pensacola (Florida) in 1976 – eight years after the introduction of the first fluorescence-based flow cytometer (1968) – it was agreed to commonly use the name "flow cytometry", a term that quickly became popular.[src] ==Flow cytometers== Modern flow cytometers are able to analyze many thousands of particles per second, in "real time" and, if configured as cell sorters, can actively separate and isolate particles with specified optical properties at similar rates.[src] A flow cytometer is similar to a microscope, except that, instead of producing an image of the cell, flow cytometry offers high-throughput, automated quantification of specified optical parameters on a cell-by-cell basis.[src] To analyze solid tissues, a single-cell suspension must first be prepared.[src] A flow cytometer has five main components: a flow cell, a measuring system, a detector, an amplification system, and a computer for analysis of the signals.[src] The flow cell has a liquid stream (sheath fluid), which carries and aligns the cells so that they pass single file through the light beam for sensing.[src] The measuring system commonly uses measurement of impedance (or conductivity) and optical systems – lamps (mercury, xenon); high-power water-cooled lasers (argon, krypton, dye laser); low-power air-cooled lasers (argon (488 nm), red-HeNe (633 nm), green-HeNe, HeCd (UV)); diode lasers (blue, green, red, violet) resulting in light signals.[src] The detector and analog-to-digital conversion (ADC) system converts analog measurements of forward-scattered light (FSC) and side-scattered light (SSC) as well as dye-specific fluorescence signals into digital signals that can be processed by a computer.[src] The amplification system can be linear or logarithmic.[src] The process of collecting data from samples using the flow cytometer is termed "acquisition".[src] Acquisition is mediated by a computer physically connected to the flow cytometer, and the software which handles the digital interface with the cytometer.[src] The software is capable of adjusting parameters (e.g., voltage, compensation) for the sample being tested, and also assists in displaying initial sample information while acquiring sample data to ensure that parameters are set correctly.[src] Early flow cytometers were, in general, experimental devices, but technological advances have enabled widespread applications for use in a variety of both clinical and research purposes.[src] Due to these developments, a considerable market for instrumentation, analysis software, as well as the reagents used in acquisition such as fluorescently labeled antibodies have been developed.[src] Modern instruments usually have multiple lasers and fluorescence detectors.[src] The current record for a commercial instrument is ten lasers and 30 fluorescence detectors.[src] Increasing the number of lasers and detectors allows for multiple antibody labeling, and can more precisely identify a target population by their phenotypic markers.[src] Certain instruments can even take digital images of individual cells, allowing for the analysis of fluorescent signal location within or on the surface of cells .[src] ==Data analysis== ===Gating=== s by side scatter and CD45, in a case with normal distributions.[src] The data generated by flow cytometers can be plotted in a single dimension to produce a histogram, or in two-dimensional dot plots, or even in three dimensions.[src] The regions on these plots can be sequentially separated, based on fluorescence intensity, by creating a series of subset extractions, termed "gates." Specific gating protocols exist for diagnostic and clinical purposes, especially in relation to hematology.[src] Individual single cells are often distinguished from cell doublets or higher aggregates by their "time-of-flight" (denoted also as a "pulse-width") through the narrowly focused laser beam The plots are often made on logarithmic scales.[src] Because different fluorescent dyes' emission spectra overlap, signals at the detectors have to be compensated electronically as well as computationally.[src] Data accumulated using the flow cytometer can be analyzed using software.[src] Once the data is collected, there is no need to stay connected to the flow cytometer and analysis is most often performed on a separate computer.[src] This is especially necessary in core facilities where usage of these machines is in high demand.[src] ===Computational analysis=== Recent progress on automated population identification using computational methods has offered an alternative to traditional gating strategies.[src] Automated identification systems could potentially help findings of rare and hidden populations.[src] Representative automated methods include FLOCK in Immunology Database and Analysis Portal (ImmPort), SamSPECTRAL and flowClust in Bioconductor, and FLAME in GenePattern.[src] T-Distributed Stochastic Neighbor Embedding (tSNE) is an algorithm designed to perform dimensionality reduction, to allow visualization of complex multi-dimensional data in a two-dimensional "map".[src] Collaborative efforts have resulted in an open project called FlowCAP (Flow Cytometry: Critical Assessment of Population Identification Methods, ) to provide an objective way to compare and evaluate the flow cytometry data clustering methods, and also to establish guidance about appropriate use and application of these methods.[src] ==Cytometric bead array== In addition to the ability to label and identify individual cells via fluorescent antibodies, cellular products such as cytokines, proteins, and other factors may be measured as well.[src] Similar to ELISA sandwich assays, cytometric bead array (CBA) assays use multiple bead populations typically differentiated by size and different levels of fluorescence intensity to distinguish multiple analytes in a single assay.[src] The amount of the analyte captured is detected via a biotinylated antibody against a secondary epitope of the protein, followed by a streptavidin-R-phycoerythrin treatment.[src] The fluorescent intensity of R-phycoerythrin on the beads is quantified on a flow cytometer equipped with a 488 nm excitation source.[src] Concentrations of a protein of interest in the samples can be obtained by comparing the fluorescent signals to those of a standard curve generated from a serial dilution of a known concentration of the analyte.[src] Commonly also referred to as cytokine bead array (CBA).[src] ==Notes==[src]
55 sentences · 55 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"Flow cytometry." encyclopegia.org, 2026, https://encyclopegia.org/wiki/flow-cytometry. Accessed 28 November 2026.
Chicago
"Flow cytometry." encyclopegia.org. Accessed November 28, 2026. https://encyclopegia.org/wiki/flow-cytometry.
APA
encyclopegia.org. (2026). Flow cytometry. Retrieved November 28, 2026, from https://encyclopegia.org/wiki/flow-cytometry
Accessed November 28, 2026 · CC BY-SA 4.0 · citation page · JSON