In respiratory medicine, a flutter valve (also Pneumostat valve, and Heimlich valve) is a one-way check valve used to prevent airflow back into a chest tube, and usually is applied to drain air from a pneumothorax.[src] The design of the flutter valve features a rubber sleeve in a plastic case, where the rubber sleeve is arranged so that when air flows through the valve the sleeve opens and allows the outwards airflow from the body of the patient; however, when the airflow is reversed, the rubber sleeve closes and halts backwards airflow into the body of the patient.[src] The construction of the flutter valve enables it to function as a one-way valve allowing airflow, or the flow of a fluid, in only one direction along the drainage tube.[src] The end of the drainage tube is placed inside the chest cavity of the patient — into the air mass or into the fluid mass to be drained from the thorax.[src] The flutter valve is placed in the appropriate orientation (designed so that the valve can only be connected in the appropriate orientation) and the pneumothorax is thus evacuated from the chest of the patient.[src] Usage of the flutter valve presents potential problems such as clogging of the chest tube, which might provoke the recurrence of the pneumothorax or the subcutaneous emphysema, which can lead to empyema.…[src]

In respiratory medicine, a flutter valve (also Pneumostat valve, and Heimlich valve) is a one-way check valve used to prevent airflow back into a chest tube, and usually is applied to drain air from a pneumothorax.[src] The design of the flutter valve features a rubber sleeve in a plastic case, where the rubber sleeve is arranged so that when air flows through the valve the sleeve opens and allows the outwards airflow from the body of the patient; however, when the airflow is reversed, the rubber sleeve closes and halts backwards airflow into the body of the patient.[src] The construction of the flutter valve enables it to function as a one-way valve allowing airflow, or the flow of a fluid, in only one direction along the drainage tube.[src] The end of the drainage tube is placed inside the chest cavity of the patient — into the air mass or into the fluid mass to be drained from the thorax.[src] The flutter valve is placed in the appropriate orientation (designed so that the valve can only be connected in the appropriate orientation) and the pneumothorax is thus evacuated from the chest of the patient.[src] Usage of the flutter valve presents potential problems such as clogging of the chest tube, which might provoke the recurrence of the pneumothorax or the subcutaneous emphysema, which can lead to empyema.[src] Another potential problem leaks of fluid, which are resolved with a small chest-drain; or with a sputum-trap attached to the valve, to function as a reservoir of the draining fluid.[src] Flutter valves (Pneumostat valves) allow patients to ambulate more easily and patients may be able leave the hospital in certain instances.[src] The traditional chest tube collection box often requires a longer hospital stay.[src] Additional to the Heimlich valve, a chest-drainage management system, which typically enables the application of vacuum, and the quantification of the effluent; however, a drainage-management system is much a larger apparatus with more tubing, which encumbers the patient.[src] ==See also== ==References==[src]

17 sentences · 17 cited inline · 0 references stored

References

No reference rows published for this article.

Cite this article

MLA

"Flutter valve." encyclopegia.org, 2026, https://encyclopegia.org/wiki/flutter-valve. Accessed 27 November 2026.

Chicago

"Flutter valve." encyclopegia.org. Accessed November 27, 2026. https://encyclopegia.org/wiki/flutter-valve.

APA

encyclopegia.org. (2026). Flutter valve. Retrieved November 27, 2026, from https://encyclopegia.org/wiki/flutter-valve

Accessed November 27, 2026 · CC BY-SA 4.0 · citation page · JSON

Related articles

Flutter

stub · references available

butterfly valve

stub · references available

aeroelastic flutter

stub · references available

safety valve

stub · references available

heart valve disease

stub · references available

pneumatic valve springs

stub · references available

snifting valve

stub · references available

atrial flutter

stub · references available
CC BY-SA 4.0 · share-alike · https://en.wikipedia.org/w/index.php?oldid=1335536155 · 0.5 · snapshot enwiki-001335536155

Cite · JSON · Search

Related services and records

Services

  • Estate — measured countries, lanes and facts
  • Intel — live corroborated events
  • Legal — statutes, cases and citations
  • Encyclopedia — articles with inline sources
  • Space — launches, satellites and orbits
  • Search — federated search and reports
  • Pass — passport account and SSO
  • Corpora — read-only corpus origins
  • e01 — self-hosted corpora and tools
  • Careers — open roles: frontier engineers and sales partners

Text and metadata only; each target carries its own sources. Missing data is published as no-data, never estimated.