The hexaxial reference system is a convention to present the extremity leads of the 12 lead electrocardiogram, that provides an illustrative logical sequence that helps interpretation of the ECG, especially to determine the heart's electrical axis in the frontal plane.[src] The most practical way of using this is by arranging extremity leads according to the Cabrera system, reversing polarity of lead aVR and presenting ECG complexes in the order (aVL, I, -aVR, II, aVF, III).[src] Then determine the direction the maximal ECG vector is "pointing", i.e.[src] in which lead there are most positive amplitude - this direction is the electrical axis - see diagram.[src] Example: If lead I has the highest amplitude (higher than aVL or -aVR), the axis is approximately 0°.[src] Conversely, if lead III has the most negative amplitude it means the vector is pointing away from this lead, i.e.[src] towards -60°.[src] An alternative use is to locate the most isoelectric (or equiphasic) lead (I, II, III, aVR, aVL, or aVF) on a diagnostic quality ECG with proper lead placement.[src] Then find the corresponding spoke on the hexaxial reference system.[src] The perpendicular spoke will point to the heart's electrical axis.[src] To determine which numerical value should be used, observe the polarity of the perpendicular lead on the ECG.…[src]

The hexaxial reference system is a convention to present the extremity leads of the 12 lead electrocardiogram, that provides an illustrative logical sequence that helps interpretation of the ECG, especially to determine the heart's electrical axis in the frontal plane.[src] The most practical way of using this is by arranging extremity leads according to the Cabrera system, reversing polarity of lead aVR and presenting ECG complexes in the order (aVL, I, -aVR, II, aVF, III).[src] Then determine the direction the maximal ECG vector is "pointing", i.e.[src] in which lead there are most positive amplitude - this direction is the electrical axis - see diagram.[src] Example: If lead I has the highest amplitude (higher than aVL or -aVR), the axis is approximately 0°.[src] Conversely, if lead III has the most negative amplitude it means the vector is pointing away from this lead, i.e.[src] towards -60°.[src] An alternative use is to locate the most isoelectric (or equiphasic) lead (I, II, III, aVR, aVL, or aVF) on a diagnostic quality ECG with proper lead placement.[src] Then find the corresponding spoke on the hexaxial reference system.[src] The perpendicular spoke will point to the heart's electrical axis.[src] To determine which numerical value should be used, observe the polarity of the perpendicular lead on the ECG.[src] For example, if the most isoelectric (or equiphasic) lead is aVL, the perpendicular lead on the hexaxial reference system is lead II.[src] If lead II is positively deflected on the ECG, the heart's electrical axis in the frontal plane will be approximately +60°.[src] Normal axis: -30° to +90° Left axis deviation: -30° to -90° Right axis deviation: +90° to +180° Extreme axis deviation: -90° to -180° ==Additional images== ==See also== Electrocardiogram ==References==[src]

25 sentences · 25 cited inline · 0 references stored

References

No reference rows published for this article.

Cite this article

MLA

"Hexaxial reference system." encyclopegia.org, 2025, https://encyclopegia.org/wiki/hexaxial-reference-system. Accessed 28 November 2026.

Chicago

"Hexaxial reference system." encyclopegia.org. Accessed November 28, 2026. https://encyclopegia.org/wiki/hexaxial-reference-system.

APA

encyclopegia.org. (2025). Hexaxial reference system. Retrieved November 28, 2026, from https://encyclopegia.org/wiki/hexaxial-reference-system

Accessed November 28, 2026 · CC BY-SA 4.0 · citation page · JSON

Related articles

Applicant Tracking System

article · references available

Solar System

stub · references available

binary numeral system

stub · references available

calendar system

stub · references available

centimeter–gram–second system of units

stub · references available

judicial system of Ukraine

stub · references available

Mac operating system

stub · references available

Public distribution system

stub · references available
CC BY-SA 4.0 · tier1-factual · https://en.wikipedia.org/w/index.php?oldid=1301207294 · 0.55 · snapshot hexaxial-reference-system-118914-cd5a21de95394230 · QID Q1024957

Cite · JSON · Search

Related services and records

Services

  • Estate — measured countries, lanes and facts
  • Intel — live corroborated events
  • Legal — statutes, cases and citations
  • Encyclopedia — articles with inline sources
  • Space — launches, satellites and orbits
  • Search — federated search and reports
  • Pass — passport account and SSO
  • Corpora — read-only corpus origins
  • e01 — self-hosted corpora and tools
  • Careers — open roles: frontier engineers and sales partners

Text and metadata only; each target carries its own sources. Missing data is published as no-data, never estimated.