IDataCool
iDataCool is a high-performance computer cluster based on a modified IBM System x iDataPlex.[src] The cluster serves as a research platform for cooling of IT equipment with hot water and efficient reuse of the waste heat.[src] The project is carried out by the physics department of the University of Regensburg in collaboration with the IBM Research and Development Laboratory Böblingen and InvenSor.[src] It is funded by the German Research Foundation (DFG), the German state of Bavaria, and IBM.[src]
iDataCool is a high-performance computer cluster based on a modified IBM System x iDataPlex.[src] The cluster serves as a research platform for cooling of IT equipment with hot water and efficient reuse of the waste heat.[src] The project is carried out by the physics department of the University of Regensburg in collaboration with the IBM Research and Development Laboratory Böblingen and InvenSor.[src] It is funded by the German Research Foundation (DFG), the German state of Bavaria, and IBM.[src] ==Overview== The iDataCool high-performance compute cluster is a research project on cooling with hot water and energy reuse in data centers.[src] The waste heat of iDataCool is used to drive an adsorption chiller that generates chilled water.[src] The project pursues the following goals: Proof of principle: production grade computer cluster can be cooled with hot water at temperatures at or above 65°C Recover a significant fraction of the waste heat Energy Reuse Effectiveness (ERE) less than one Design of a cost-efficient technology prototype for future developments in high-performance computer design and operation The iDataCool cluster has been operating with hot-water cooling since 2011.[src] The infrastructure support for energy reuse was finished in 2012.[src] Members of the project have also been active in other supercomputer projects such as QCDOC and QPACE.[src] SuperMUC is based on the cooling technology invented for QPACE, Aquasar, and iDataCool.[src] The iDataCool research project was presented at the International Supercomputing Conference in Leipzig, Germany, in 2013, which led to it being featured in several articles.[src] ==Background and design target== Power and cooling of IT equipment are of major concern for modern data centers.[src] Since 1996 the worldwide costs for power and cooling of IT infrastructure have increased by more than a factor of five.[src] Conventionally, data centers use air as the primary cooling medium for the IT equipment.[src] While air cooling is simple and flexible it also has some disadvantages, e.g., limited packaging density and limited options for energy reuse.[src] Liquid cooling based on water as the coolant is another option.[src] Since water has a very high heat capacity large amounts of heat can be removed from a system at moderate flow rates, thus allowing for a higher packaging density which in turn results in less floor space.[src] Liquid cooling has recently resurfaced in the sector of high-performance computing.[src] Since 2009 the Green500 list of the most energy-efficient supercomputers is dominated by liquid-cooled designs.[src] If the design of the liquid-cooling system allows for high coolant temperatures, energy can be saved or even reused, depending on the climate conditions and on the local infrastructure.[src] For example, free cooling is possible if the coolant temperature is higher than the ambient temperature.[src] In that case the energy for chillers can be saved.[src] If the coolant temperature is even higher, the waste heat from the compute equipment could be used for heating purposes or to drive an adsorption chiller to generate chilled water.[src] The former option is implemented, e.g., by the Leibniz-Rechenzentrum in Germany, where SuperMUC drives the heating of the data center during winter with roughly 1 MW recovered from the compute equipment.[src] The latter option, which is the design target of iDataCool, requires a high quality of the heat, which can only be achieved by direct hot-water cooling.[src] One example for direct hot-water cooling is the Aquasar project at ETH Zürich, which is operated at coolant temperatures around 60°C.[src] The aim of iDataCool was to achieve coolant temperatures of more than 65°C, at which commercially available adsorption chillers tend to become efficient, and to demonstrate the long-term stability of a large production machine under these conditions.[src] ==Architecture== The iDataCool installation at the University of Regensburg consists of three IBM System x iDataPlex racks.[src] Each rack contains 72 compute nodes.[src] A compute node consists of two Intel Xeon Westmere server processors and is arranged as a distributed shared memory system with 24 GB of DDR3-SDRAM.[src] Switched Infiniband is used for communication amongst the nodes.[src] Gigabit Ethernet is used for disk I/O, system operation, and monitoring.[src] The original iDataPlex system is entirely cooled by air.[src] The ambient air in the data center is drawn in through perforated front doors, and the hot air is blown back into the data center on the back side.[src] Components that need cooling are the power supplies, network switches, and compute nodes.[src] The power supplies and switches rely on built-in fans which generate the necessary air-flow, while fan blocks are used to draw the air over the compute nodes, which are equipped with passive heat sinks.[src] In a joint effort of the particle physics group of the University of Regensburg and the IBM Research and Development Laboratory Böblingen, Germany, a water-cooling solution for the compute nodes was developed which completely replaces the original fans and heat sinks.[src] The processors are cooled by custom-designed copper heat sinks through which water flows directly.[src] This minimizes the temperature difference between the compute cores and the coolant.[src] A copper pipeline provides the water flow and is also thermally coupled to passive heat sinks for other components such as memory, chipset, and voltage converters.[src] All conversions of the original iDataPlex cluster were performed at the University of Regensburg.[src] Newly developed parts were manufactured in the machine shop of the university's physics department.[src] The data center of the university was extended to provide the liquid-cooling infrastructure.[src] The system has been operating in stable production mode at coolant temperatures of up to 70°C since 2011.[src] ==Energy reuse== iDataCool allows for cooling with hot water at temperatures of up to 70°C.[src] The waste heat of iDataCool drives a low-temperature adsorption chiller (LTC 09 by InvenSor) that works efficiently already at temperatures around 65°C.[src] The chiller generates chilled water that is used to cool other compute equipment in the data center.[src] The installation was finished in the summer of 2012.[src] ==See also== Data center HVAC Liquid cooling for computers Absorption refrigerator Computer cluster QPACE QPACE2 SuperMUC Aquasar ==References==[src]
53 sentences · 53 cited inline · 0 references stored
References
No reference rows published for this article.
Cite this article
MLA
"IDataCool." encyclopegia.org, 2024, https://encyclopegia.org/wiki/idatacool. Accessed 27 November 2026.
Chicago
"IDataCool." encyclopegia.org. Accessed November 27, 2026. https://encyclopegia.org/wiki/idatacool.
APA
encyclopegia.org. (2024). IDataCool. Retrieved November 27, 2026, from https://encyclopegia.org/wiki/idatacool
Accessed November 27, 2026 · CC BY-SA 4.0 · citation page · JSON