Kinematic diffraction
Kinematic diffraction is an approximation for diffraction of waves. It assumes that the waves are only scattered once, neglecting multiple scattering. For linear wave equations, it involves summing the contribution of the partial waves emanating from different scatterers, where only the incident field drives the scattering. As a consequence, the far-field amplitude essentially corresponds to the Fourier transform of the scattering length density. It would be the charge density for x-rays and the electrostatic potential for electrons. It is typically understood as the Born approximation applied to a number of scatterers, and as such is often used for X-ray crystallography. In the kinematic approximation, the scattered amplitude can be written as the Fourier transform of the scattering density, : A(\mathbf{q})=\int \rho(\mathbf{r}) e^{i\mathbf{q}\cdot\mathbf{r}}\,d^3r, where \mathbf{q} is the scattering vector and \rho(\mathbf{r}) is the scattering density. The corresponding diffracted intensity is proportional to the squared magnitude of the amplitude, : I(\mathbf{q})\propto |A(\mathbf{q})|^2. The corresponding full theory is called the dynamical theory of diffraction.…
Kinematic diffraction is an approximation for diffraction of waves. It assumes that the waves are only scattered once, neglecting multiple scattering. For linear wave equations, it involves summing the contribution of the partial waves emanating from different scatterers, where only the incident field drives the scattering. As a consequence, the far-field amplitude essentially corresponds to the Fourier transform of the scattering length density. It would be the charge density for x-rays and the electrostatic potential for electrons. It is typically understood as the Born approximation applied to a number of scatterers, and as such is often used for X-ray crystallography. In the kinematic approximation, the scattered amplitude can be written as the Fourier transform of the scattering density, A(\mathbf{q})=\int \rho(\mathbf{r}) e^{i\mathbf{q}\cdot\mathbf{r}}\,d^3r, where \mathbf{q} is the scattering vector and \rho(\mathbf{r}) is the scattering density. The corresponding diffracted intensity is proportional to the squared magnitude of the amplitude, I(\mathbf{q})\propto |A(\mathbf{q})|^2. The corresponding full theory is called the dynamical theory of diffraction. For x-rays and in electron diffraction different approaches are used for calculating the dynamical diffraction for transmission: with high-energy electrons, for low energy electron diffraction, or reflection high-energy electron diffraction ==References==
References
No reference rows published for this article.
Cite this article
MLA
"Kinematic diffraction." encyclopegia.org, 2026, https://encyclopegia.org/wiki/kinematic-diffraction. Accessed 24 November 2026.
Chicago
"Kinematic diffraction." encyclopegia.org. Accessed November 24, 2026. https://encyclopegia.org/wiki/kinematic-diffraction.
APA
encyclopegia.org. (2026). Kinematic diffraction. Retrieved November 24, 2026, from https://encyclopegia.org/wiki/kinematic-diffraction
Accessed November 24, 2026 · CC BY-SA 4.0 · citation page · JSON